New wearable system for step-counting telemonitoring and telerehabilitation based on the Codivilla spring.

During stroke rehabilitation at home, the most used equipment is the Codivilla spring for both bilateral and one-side stroke damage. A novel Codivilla spring prosthesis has been electronically sensorized in order to allow new functionalities pertinent to telerehabilitation, such as the step counting and biofeedback mapping of gait-phases. The principal elements of the electronics are a couple of force-sensing resistors affixed in the plantar area of the prosthesis, and a wearable unit with a microprocessor-based on Microchip technology (Microchip Technology, Inc., Chandler, AZ) for data processing and a telemetric system based on Aurel technology (Aurel, Modigliana, Italy) for data tansfer. While ambulating, the foot-sensing resistors detect the pressure of the foot-tip and heel. The microprocessor provides step-counting on the basis of an algorithm. The microprocessor also drives two vibrotactile actuators (one at the foot-tip and the other at the heel). These actuators are fixed at the level of the belt directly in contact with the skin and give biofeedback mapping of the gait-phases to the patient wearing the prosthesis, who can then walk without looking at his or her feet. The sensorized prosthesis was tested on six subjects undergoing stroke rehabilitation at level 2 of the Tinetti test. These subjects performed five repetitions of 100 steps with three different instructions (fast, slow, and normal). The mean error was lower than 0.6%. A test conducted by means of Cosmed devices (Cosmed USA, Chicago, IL) also showed that the biofeedback function provided by means of the actuators diminished the energy expenditure by 0.7% in mean value. The next phase will be the optimization of the equipment for long-term medical application in a patient's home.

[1]  Daniele Giansanti,et al.  New neural network classifier of fall-risk based on the Mahalanobis distance and kinematic parameters assessed by a wearable device , 2008, Physiological measurement.

[2]  Daniele Giansanti,et al.  Assessment of fall-risk by means of a neural network based on parameters assessed by a wearable device during posturography. , 2008, Medical engineering & physics.

[3]  D Walsh,et al.  Utility of pedometer step recommendations for predicting overweight in children , 2007, International Journal of Obesity.

[4]  S. Adamovich,et al.  Sensorimotor Training in a Virtual Reality Environment: Does It Improve Functional Recovery Poststroke? , 2006, Neurorehabilitation and neural repair.

[5]  Kaberi Dasgupta,et al.  Walking behaviour and glycemic control in type 2 diabetes: seasonal and gender differences-Study design and methods , 2007, Cardiovascular diabetology.

[6]  Changes in motoneuron excitability in hemiplegic subjects after passive exercise when using a robotic arm. , 2006, Archives of physical medicine and rehabilitation.

[7]  D. Giansanti Investigation of fall-risk using a wearable device with accelerometers and rate gyroscopes , 2006, Physiological measurement.

[8]  R. Waters,et al.  The energy expenditure of normal and pathologic gait. , 1999, Gait & posture.

[9]  Daniele Giansanti,et al.  The development and test of a device for the reconstruction of 3-D position and orientation by means of a kinematic sensor assembly with rate gyroscopes and accelerometers , 2005, IEEE Transactions on Biomedical Engineering.

[10]  S. Adamovich,et al.  Virtual reality-augmented rehabilitation for patients following stroke. , 2002, Physical therapy.

[11]  Carolyn Albright,et al.  The effectiveness of walking in preventing cardiovascular disease in women: a review of the current literature. , 2006, Journal of women's health.

[12]  D. Good Stroke: Promising Neurorehabilitation Interventions and Steps Toward Testing Them , 2003, American journal of physical medicine & rehabilitation.

[13]  D. Bassett,et al.  Pedometer measures of free-living physical activity: comparison of 13 models. , 2004, Medicine and science in sports and exercise.

[14]  Daniele Giansanti,et al.  Telemonitoring and telerehabilitation of patients with Parkinson's disease: health technology assessment of a novel wearable step counter. , 2008, Telemedicine journal and e-health : the official journal of the American Telemedicine Association.