Deformable model for 3D intramodal nonrigid breast image registration with fiducial skin markers

We implemented a new approach to intramodal non-rigid 3D breast image registration. Our method uses fiducial skin markers (FSM) placed on the breast surface. After determining the displacements of FSM, finite element method (FEM) is used to distribute the markers’ displacements linearly over the entire breast volume using the analogy between the orthogonal components of the displacement field and a steady state heat transfer (SSHT). It is valid because the displacement field in x, y and z direction and a SSHT problem can both be modeled using LaPlace’s equation and the displacements are analogous to temperature differences in SSHT. It can be solved via standard heat conduction FEM software with arbitrary conductivity of surface elements significantly higher than that of volume elements. After determining the displacements of the mesh nodes over the entire breast volume, moving breast volume is registered to target breast volume using an image warping algorithm. Very good quality of the registration was obtained. Following similarity measurements were estimated: Normalized Mutual Information (NMI), Normalized Correlation Coefficient (NCC) and Sum of Absolute Valued Differences (SAVD). We also compared our method with rigid registration technique.

[1]  R.J. Maciunas,et al.  An automatic technique for finding and localizing externally attached markers in CT and MR volume images of the head , 1996, IEEE Transactions on Biomedical Engineering.

[2]  Dimitris N. Metaxas,et al.  Methods for modeling and predicting mechanical deformations of the breast under external perturbations , 2002, Medical Image Anal..

[3]  Martin J. Yaffe,et al.  Biomechanical 3-D finite element modeling of the human breast using MRI data , 2001, IEEE Transactions on Medical Imaging.

[4]  Alejandro F. Frangi,et al.  Automatic Construction of 3D Statistical Deformation Models Using Non-rigid Registration , 2001, MICCAI.

[5]  David J. Hawkes,et al.  Validation of nonrigid image registration using finite-element methods: application to breast MR images , 2003, IEEE Transactions on Medical Imaging.

[6]  Wei Li,et al.  Intermodality nonrigid breast-image registration , 2004, 2004 2nd IEEE International Symposium on Biomedical Imaging: Nano to Macro (IEEE Cat No. 04EX821).

[7]  J. Z. Zhu,et al.  The finite element method , 1977 .

[8]  Haiying Liu,et al.  Constructing Patient Specific Models for Correcting Intraoperative Brain Deformation , 2001, MICCAI.

[9]  Min Luo,et al.  Inter-modality non-rigid breast image registration using finite-element method , 2003, 2003 IEEE Nuclear Science Symposium. Conference Record (IEEE Cat. No.03CH37515).

[10]  Dimitris N. Metaxas,et al.  Methods for Modeling and Predicting Mechanical Deformations of the Breast Under External Perturbations , 2001, MICCAI.

[11]  William M. Wells,et al.  Medical Image Computing and Computer-Assisted Intervention — MICCAI’98 , 1998, Lecture Notes in Computer Science.

[12]  A. Sitek,et al.  Deformable model of the heart with fiber structure , 2000, 2000 IEEE Nuclear Science Symposium. Conference Record (Cat. No.00CH37149).

[13]  Daniel Rueckert,et al.  Nonrigid registration using free-form deformations: application to breast MR images , 1999, IEEE Transactions on Medical Imaging.

[14]  Paul A. Viola,et al.  Alignment by Maximization of Mutual Information , 1995, Proceedings of IEEE International Conference on Computer Vision.

[15]  R. Cook,et al.  Concepts and Applications of Finite Element Analysis , 1974 .