Trabecular surface remodeling simulation for cancellous bone using microstructural voxel finite element models.

A computational simulation method for three-dimensional trabecular surface remodeling was proposed, using voxel finite element models of cancellous bone, and was applied to the experimental data. In the simulation, the trabecular microstructure was modeled based on digital images, and its morphological changes due to surface movement at the trabecular level were directly expressed by removing/adding the voxel elements from/to the trabecular surface. A remodeling simulation at the single trabecular level under uniaxial compressive loading demonstrated smooth morphological changes even though the trabeculae were modeled with discrete voxel elements. Moreover, the trabecular axis rotated toward the loading direction with increasing stiffness, simulating functional adaptation to the applied load. In the remodeling simulation at the trabecular structural level, a cancellous bone cube was modeled using a digital image obtained by microcomputed tomography (microCT), and was uniaxially compressed. As a result, the apparent stiffness against the applied load increased by remodeling, in which the trabeculae reoriented to the loading direction. In addition, changes in the structural indices of the trabecular architecture coincided qualitatively with previously published experimental observations. Through these studies, it was demonstrated that the newly proposed voxel simulation technique enables us to simulate the trabecular surface remodeling and to compare the results obtained using this technique with the in vivo experimental data in the investigation of the adaptive bone remodeling phenomenon.

[1]  N. Kikuchi,et al.  Homogenization theory and digital imaging: A basis for studying the mechanics and design principles of bone tissue , 1994, Biotechnology and bioengineering.

[2]  P. Rüegsegger,et al.  Calibration of trabecular bone structure measurements of in vivo three-dimensional peripheral quantitative computed tomography with 28-microm-resolution microcomputed tomography. , 1999, Bone.

[3]  R E Guldberg,et al.  Trabecular bone adaptation to variations in porous-coated implant topology. , 1997, Journal of biomechanics.

[4]  S C Cowin,et al.  Bone ingrowth: an application of the boundary element method to bone remodeling at the implant interface. , 1993, Journal of biomechanics.

[5]  J. Ferrier,et al.  Propagation of a calcium pulse between osteoblastic cells. , 1992, Biochemical and biophysical research communications.

[6]  T. Adachi,et al.  Uniform stress state in bone structure with residual stress. , 1998, Journal of biomechanical engineering.

[7]  Rik Huiskes,et al.  Effects of mechanical forces on maintenance and adaptation of form in trabecular bone , 2000, Nature.

[8]  J. C. Simo,et al.  Adaptive bone remodeling incorporating simultaneous density and anisotropy considerations. , 1997, Journal of biomechanics.

[9]  S. Cowin,et al.  Candidates for the mechanosensory system in bone. , 1991, Journal of biomechanical engineering.

[10]  H Weinans,et al.  A physiological approach to the simulation of bone remodeling as a self-organizational control process. , 1994, Journal of biomechanics.

[11]  P Rüegsegger,et al.  Effect of mechanical set point of bone cells on mechanical control of trabecular bone architecture. , 1998, Bone.

[12]  A. Parfitt Osteonal and hemi‐osteonal remodeling: The spatial and temporal framework for signal traffic in adult human bone , 1994, Journal of cellular biochemistry.

[13]  R E Guldberg,et al.  Mechanical Stimulation of Tissue Repair in the Hydraulic Bone Chamber , 1997, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[14]  R. Huiskes,et al.  A new method to determine trabecular bone elastic properties and loading using micromechanical finite-element models. , 1995, Journal of biomechanics.

[15]  R E Guldberg,et al.  The accuracy of digital image-based finite element models. , 1998, Journal of biomechanical engineering.

[16]  P. Rüegsegger,et al.  Finite element analysis of trabecular bone structure: a comparison of image-based meshing techniques. , 1998, Journal of biomechanics.

[17]  H. Grootenboer,et al.  Adaptive bone-remodeling theory applied to prosthetic-design analysis. , 1987, Journal of biomechanics.

[18]  L. S. Matthews,et al.  Trabecular bone remodeling: an experimental model. , 1991, Journal of biomechanics.

[19]  A. Sadegh,et al.  An evolutionary Wolff's law for trabecular architecture. , 1992, Journal of biomechanical engineering.

[20]  Masao Tanaka,et al.  Simulation of Trabecular Surface Remodeling based on Local Stress Nonuniformity. , 1997 .

[21]  S. Hollister,et al.  Image Based Design and Manufacture of Scaffolds for Bone Reconstruction , 1999 .

[22]  MICHAEL I. MIGA,et al.  In Vivo Analysis of Heterogeneous Brain Deformation Computations for Model-Updated Image Guidance , 2000, Computer methods in biomechanics and biomedical engineering.

[23]  S. Goldstein,et al.  The direct examination of three‐dimensional bone architecture in vitro by computed tomography , 1989, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[24]  N. Kikuchi,et al.  A homogenization sampling procedure for calculating trabecular bone effective stiffness and tissue level stress. , 1994, Journal of biomechanics.

[25]  H. M. Frost Structural Adaptations to Mechanical Usage. A Proposed “Three-Way Rule” for Bone Modeling: Part II , 1988 .

[26]  R Huiskes,et al.  From structure to process, from organ to cell: recent developments of FE-analysis in orthopaedic biomechanics. , 1993, Journal of biomechanical engineering.

[27]  H J Donahue,et al.  Cell‐to‐cell communication in osteoblastic networks: Cell line–dependent hormonal regulation of gap junction function , 1995, Journal of bone and mineral research : the official journal of the American Society for Bone and Mineral Research.

[28]  Thomas J. R. Hughes,et al.  LARGE-SCALE VECTORIZED IMPLICIT CALCULATIONS IN SOLID MECHANICS ON A CRAY X-MP/48 UTILIZING EBE PRECONDITIONED CONJUGATE GRADIENTS. , 1986 .

[29]  S C Cowin,et al.  Bone stress adaptation models. , 1993, Journal of biomechanical engineering.

[30]  Masao Tanaka,et al.  Three-Dimensional Lattice Continuum Model of Cancellous Bone for Structural and Remodeling Simulation , 1999 .

[31]  R. Huiskes,et al.  Direct mechanics assessment of elastic symmetries and properties of trabecular bone architecture. , 1996, Journal of biomechanics.

[32]  S C Cowin,et al.  Implementation of strain rate as a bone remodeling stimulus. , 1995, Journal of biomechanical engineering.