Neo-SENSE: a non-invasive smart sensing mattress for cardiac monitoring of babies

Within the first minute of life a newborn must take its first breath to make the transition from life inside the womb to the outside world. If a baby does not start breathing, its heart rate will drop and the circulation of blood carrying oxygen to the organs will be seriously affected. The damage done to a newborn who is deprived of oxygen happens so quickly that rapid response is imperative. During birth, the attending neonatal staff manually listen to the baby´s heart and count the heart rate; however, this has proven inaccurate and inefficient. Nowadays, there is not a reliable method to monitor newborn heart rate promptly throughout birth. In this paper, we report the design and development of a novel smart mattress device to measure the babies’ electrocardiogram and respiration non-invasively. The device is based on electrometer-based amplifier sensors combined with novel screen-printing techniques. Proof of concept tests are carried out to demonstrate the suitability of the smart-mattress for new born ECG monitoring. We perform tests with a young infant and demonstrate the potential of this sensing technology to provide a quick and reliable application as ECG readings were displayed within a time < 30 seconds. This will aid the neonatal staff to assess the success of the resuscitation technology aiming to lower the incidence of long-term consequences of poor adaptation to life outside the womb.

[1]  S. Beeby,et al.  Waterproof and durable screen printed silver conductive tracks on textiles , 2013 .

[2]  B. B. Narakathu,et al.  Development of printed and flexible dry ECG electrodes , 2018, Sensing and Bio-Sensing Research.

[3]  R. J. Prance,et al.  Noninvasive imaging of signals in digital circuits , 2002 .

[4]  T. Rootwelt,et al.  Response to resuscitation of the newborn: Early prognostic variables , 2005 .

[5]  T. Clark,et al.  Noninvasive imaging using an array of electric potential sensors , 2006 .

[6]  Helen Prance,et al.  Non-invasive electrocardiogram detection of in vivo zebrafish embryos using electric potential sensors , 2015 .

[7]  Peter G Davis,et al.  A systematic review of novel technology for monitoring infant and newborn heart rate , 2017, Acta paediatrica.

[8]  E. Dempsey,et al.  Enhanced Monitoring of the Preterm Infant during Stabilization in the Delivery Room , 2016, Front. Pediatr..

[9]  Luca Fanucci,et al.  Sensing Devices and Sensor Signal Processing for Remote Monitoring of Vital Signs in CHF Patients , 2013, IEEE Transactions on Instrumentation and Measurement.

[10]  Hal B. Jenson,et al.  Nelson Textbook of Pediatrics , 1965 .

[11]  R. J. Prance,et al.  Non-invasive recordings of fetal electrocardiogram during pregnancy using electric potential sensors , 2018, AIP Advances.

[12]  H. Pomerance,et al.  Nelson Textbook of Pediatrics. , 1997, Archives of pediatrics & adolescent medicine.

[13]  H. Mizumoto,et al.  Electrocardiogram shows reliable heart rates much earlier than pulse oximetry during neonatal resuscitation , 2012, Pediatrics international : official journal of the Japan Pediatric Society.

[14]  R. Prance,et al.  Imaging electrostatic fingerprints with implications for a forensic timeline. , 2011, Forensic science international.

[15]  C. O. Kamlin,et al.  Feasibility of and delay in obtaining pulse oximetry during neonatal resuscitation. , 2005, The Journal of pediatrics.

[16]  J. Carlin,et al.  Reference ranges for respiratory rate measured by thermistry (12-84 months). , 1993, Archives of disease in childhood.