RELIABILITY AND VALIDITY OF THREE STRENGTH MEASURES OBTAINED FROM COMMUNITY‐DWELLING ELDERLY PERSONS

The purpose of this study was to describe the reliability and validity of 3 strength measures obtained from community-dwelling elderly individuals. The strength of 10 elders was tested initially and 6 and 12 weeks later using the MicroFET 2 hand-held dynamometer (knee extension strength), the Jamar dynamometer (grip strength), and the sit-to-stand (STS) test. Mobility was tested using the timed up-and-go (TUG) test and a timed walk test. Intraclass correlation coefficients, which were used to characterize the reliability of the strength tests, ranged from 0.807 to 0.981. Pearson correlations between the lower extremity strength measures and the TUG and gait speed ranged from 0.635 to 20.943. Our examination of the 3 measures for 12 weeks extends previous evidence of the stability of these strength measures and justifies the use of hand-held dynamometry and the STS test when investigating limitations in mobility.

[1]  V. Mathiowetz,et al.  Grip and pinch strength: normative data for adults. , 1985, Archives of physical medicine and rehabilitation.

[2]  Frank D. Sills,et al.  The Relationship of Grip Strength to Stature, Somatotype Components, and Anthropometric Measurements of the Hand , 1952 .

[3]  S D Walter,et al.  Measuring the reliability of clinical data: the case for using three observers. , 1984, Revue d'epidemiologie et de sante publique.

[4]  Richard W. Bohannon,et al.  Reliability and Validity of Measurements of Knee Extension Force Obtained by Hand‐held Dynamometry from Community Dwelling Elderly Women , 2001 .

[5]  J. Fleiss The design and analysis of clinical experiments , 1987 .

[6]  V. Mathiowetz,et al.  Reliability and validity of grip and pinch strength evaluations. , 1984, The Journal of hand surgery.

[7]  Laura Ray,et al.  Handgrip Strength and Mortality in Older Mexican Americans , 2002, Journal of the American Geriatrics Society.

[8]  Diane Podsiadlo,et al.  The Timed “Up & Go”: A Test of Basic Functional Mobility for Frail Elderly Persons , 1991, Journal of the American Geriatrics Society.

[9]  L. Ferrucci,et al.  Hand-grip strength predicts incident disability in non-disabled older men. , 1999, Age and ageing.

[10]  M. Samson,et al.  Strength, mobility and falling in women referred to a geriatric outpatient clinic , 2004, Aging clinical and experimental research.

[11]  C. Goldsmith,et al.  Muscle Weakness and Falls in Older Adults: A Systematic Review and Meta‐Analysis , 2004, Journal of the American Geriatrics Society.

[12]  Reliability of Lower Extremity Strength Measurements Using the Belt-Resisted Method , 1998 .

[13]  T. Kamimura,et al.  Evaluation of grip strength with a sustained maximal isometric contraction for 6 and 10 seconds. , 2001, Journal of rehabilitation medicine.

[14]  L. Ploutz-Snyder,et al.  Orientation and Familiarization to 1RM Strength Testing in Old and Young Women , 2001, Journal of strength and conditioning research.

[15]  Richard W. Bohannon Hand-grip dynamometry provides a valid indication of upper extremity strength impairment in home care patients. , 1998, Journal of Hand Therapy.

[16]  R. Kington,et al.  Reliability and Prevalence of Physical Performance Examination Assessing Mobility and Balance in Older Persons in the US: Data from the Third National Health and Nutrition Examination Survey , 2000, Journal of the American Geriatrics Society.

[17]  A M Jette,et al.  Are performance-based measures sufficiently reliable for use in multicenter trials? Musculoskeletal Impairment (MSI) Study Group. , 1999, The journals of gerontology. Series A, Biological sciences and medical sciences.

[18]  Richard W. Bohannon,et al.  Hand-held Dynamometer Measurements: Tester Strength Makes a Difference. , 1991, The Journal of orthopaedic and sports physical therapy.

[19]  Elaine Ewing Fess,et al.  Clinical assessment Recommendations , 1981 .

[20]  Richard W. Bohannon Comfortable and maximum walking speed of adults aged 20-79 years: reference values and determinants. , 1997, Age and ageing.

[21]  R W Bohannon,et al.  Normative values for isometric muscle force measurements obtained with hand-held dynamometers. , 1996, Physical therapy.

[22]  Richard W. Bohannon Hand‐held dynamometer measurements obtained in a home environment are reliable but not correlated strongly with function , 1996, International journal of rehabilitation research. Internationale Zeitschrift fur Rehabilitationsforschung. Revue internationale de recherches de readaptation.

[23]  Slobodan Jaric,et al.  Muscle Strength Assessment From Functional Performance Tests: Role of Body Size , 2003, Journal of strength and conditioning research.

[24]  Reliability of Knee Extensor and Flexor Strength Measurements After Total Knee Replacement , 1992 .