A Wearable Pulse Oximeter With Wireless Communication and Motion Artifact Tailoring for Continuous Use

Advances in several engineering fields have led to a trend toward miniaturization and portability of wearable biosensing devices, which used to be confined to large tools and clinical settings. Various systems to continuously measure electrophysiological activity through electrical and optical methods are one category of such devices. Being wearable and intended for prolonged use, the amount of noise introduced on sensors by movement remains a challenge and requires further optimization. User movement causes motion artifacts that alter the overall quality of the signals obtained, hence corrupting the resulting measurements. This paper introduces a fully wearable optical biosensing system to continuously measure pulse oximetry and heart rate, utilizing a reflectance-based probe. Furthermore, a novel data-dependent motion artifact tailoring algorithm is implemented to eliminate noisy data due to the motion artifact and measure oxygenation level with high accuracy in real time. By taking advantages of current wireless transmission and signal processing technologies, the developed wearable photoplethysmography device successfully captures the measured signals and sends them wirelessly to a mobile device for signal processing in real time. After applying motion artifact tailoring, evaluating accuracy with a continuous clinical device, the blood oxygenation measurements obtained from our system yielded an accuracy of at least 98%, when compared to a range of 93.6%–96.7% observed before from the same initial data. Additionally, heart rate accuracy above 97% was achieved. Motion artifact tailoring and removal in real time, continuous systems will allow wearable devices to be truly wearable and a reliable electrophysiological monitoring and diagnostics tool for everyday use.

[1]  Hsiao-Chun Wu,et al.  Novel tailoring algorithm for abrupt motion artifact removal in photoplethysmogram signals , 2017, Biomedical engineering letters.

[2]  Yuan-Ting Zhang,et al.  Continuous Cuffless Blood Pressure Estimation Using Pulse Transit Time and Photoplethysmogram Intensity Ratio , 2016, IEEE Transactions on Biomedical Engineering.

[3]  Fundamental Study of Reflection Pulse Oximetry , 2003 .

[4]  Dermot Phelan,et al.  Accuracy of Wrist-Worn Heart Rate Monitors , 2017, JAMA cardiology.

[5]  W. Zijlstra,et al.  Spectrophotometry of Hemoglobin: Absorption Spectra of Bovine Oxyhemoglobin, Deoxyhemoglobin, Carboxyhemoglobin, and Methemoglobin , 1997 .

[6]  Siegfried Kästle,et al.  A New Family of Sensors for Pulse Oximetry This new family of reusable sensors for noninvasive arterial oxygen saturation measurements is designed to cover all application areas. It consists of four sensors: adult, pediatric, neonatal, and ear clip. , 1997 .

[7]  K. Kaye,et al.  Utility of Pulse Oximetry in Diagnosing Pneumonia in Nursing Home Residents , 2002, The American journal of the medical sciences.

[8]  Yuan-Ting Zhang,et al.  A preliminary study on multi-wavelength PPG based pulse transit time detection for cuffless blood pressure measurement , 2016, 2016 38th Annual International Conference of the IEEE Engineering in Medicine and Biology Society (EMBC).

[9]  Franklin A. Graybill,et al.  Introduction to the Theory of Statistics, 3rd ed. , 1974 .

[10]  J. Sinex Pulse oximetry: principles and limitations. , 1999, The American journal of emergency medicine.

[11]  K. Birkelund,et al.  A Ring-Shaped Photodiode Designed for Use in a Reflectance Pulse Oximetry Sensor in Wireless Health Monitoring Applications , 2010, IEEE Sensors Journal.

[12]  C. Poets,et al.  Reference values for nocturnal home pulse oximetry during sleep in primary school children. , 2003, Chest.

[13]  Y. Mendelson,et al.  Noninvasive pulse oximetry utilizing skin reflectance photoplethysmography , 1988, IEEE Transactions on Biomedical Engineering.

[14]  Mohamed Ismail Nounou,et al.  Are Currently Available Wearable Devices for Activity Tracking and Heart Rate Monitoring Accurate, Precise, and Medically Beneficial? , 2015, Healthcare informatics research.

[15]  N. Gupta,et al.  Blind multiridge detection for automatic nondestructive testing using ultrasonic signals , 2006, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  Survi Kyal,et al.  Toward Ubiquitous Blood Pressure Monitoring via Pulse Transit Time: Theory and Practice , 2015, IEEE Transactions on Biomedical Engineering.

[17]  Trevor Hastie,et al.  Accuracy in wrist-worn, sensor-based measurements of heart rate and energy expenditure in a diverse cohort , 2016 .

[18]  John A Rogers,et al.  Miniaturized Battery‐Free Wireless Systems for Wearable Pulse Oximetry , 2017, Advanced functional materials.

[19]  Albrecht Schmidt,et al.  Applying wearable sensors to avalanche rescue , 2003, Comput. Graph..

[20]  Claire M. Lochner,et al.  All-organic optoelectronic sensor for pulse oximetry , 2014, Nature Communications.

[21]  U. Wisløff,et al.  Accuracy of Heart Rate Watches: Implications for Weight Management , 2016, PloS one.