Design and validation of a novel 3D-printed wearable device for monitoring knee joint kinematics.

Gait analysis provides an important tool for the study and clinical evaluation of conditions which affect knee joint biomechanics. Collection of knee joint kinematics in real world environments during locomotor activities of daily living could provide quantitative evidence to help understand functional impairment. Unfortunately, the high cost and necessary technical expertise associated with current commercially available systems for kinematic monitoring serve as an impediment to their adoption outside of specialized research groups. We have developed a low-cost, custom wearable device to address these shortcomings. The 3D printed device is capable of measuring knee flexion/extension (F/E) and adduction/abduction (AD/AB) angles. Here, we present a gold standard validation of the novel device against an optoelectronic motion capture system (MCS). Data were collected during a treadmill walking task from 8 participants on 2 separate occasions. Agreement with the MCS was quantified via root mean squared error (RMSE), coefficients of multiple correlation (CMC), paired dependent t-tests and Bland-Altman analyses. The wearable device had an overall RMSE of 3.0° and 2.7° and a CMC of 0.97 and 0.91 in F/E and AD/AB respectively. Wearable device error showed no significant differences between test occasions, and Bland-Altman analyses showed low bias with narrow limits of agreement. These results demonstrate the capability of the device to accurately and reliably monitor knee F/E and AD/AB angles showing strong potential for field implementation.

[1]  Pietro Garofalo,et al.  First in vivo assessment of “Outwalk”: a novel protocol for clinical gait analysis based on inertial and magnetic sensors , 2009, Medical & Biological Engineering & Computing.

[2]  Qingguo Li,et al.  Concurrent validation of Xsens MVN measurement of lower limb joint angular kinematics , 2013, Physiological measurement.

[3]  M. Akai,et al.  Association between in vivo knee kinematics during gait and the severity of knee osteoarthritis. , 2012, The Knee.

[4]  M P Kadaba,et al.  Measurement of lower extremity kinematics during level walking , 1990, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[5]  Aurelio Cappozzo,et al.  Joint kinematics estimate using wearable inertial and magnetic sensing modules. , 2008, Gait & posture.

[6]  Christian A. Clermont,et al.  The use of wearable devices for walking and running gait analysis outside of the lab: A systematic review. , 2018, Gait & posture.

[7]  R. B. Davis,et al.  A gait analysis data collection and reduction technique , 1991 .

[8]  Alison H. McGregor,et al.  A flexible wearable sensor for knee flexion assessment during gait , 2018, Gait & posture.

[9]  F. Noyes,et al.  Ligamentous restraints to anterior-posterior drawer in the human knee. A biomechanical study. , 1980, The Journal of bone and joint surgery. American volume.

[10]  Anthony G Schache,et al.  Three‐dimensional motion of the knee‐joint complex during normal walking revealed by mobile biplane x‐ray imaging , 2019, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[11]  Masahiro Todoh,et al.  Gait posture estimation using wearable acceleration and gyro sensors. , 2009, Journal of biomechanics.

[12]  M. Wimmer,et al.  Differences in preferred walking speeds in a gait laboratory compared with the real world after total hip replacement. , 2010, Archives of physical medicine and rehabilitation.

[13]  Li-Qun Zhang,et al.  Six degrees-of-freedom kinematics of ACL deficient knees during locomotion-compensatory mechanism. , 2003, Gait & posture.

[14]  Terry K Koo,et al.  A Guideline of Selecting and Reporting Intraclass Correlation Coefficients for Reliability Research. , 2016, Journal Chiropractic Medicine.

[15]  T. Andriacchi,et al.  Interactions between kinematics and loading during walking for the normal and ACL deficient knee. , 2005, Journal of biomechanics.

[16]  R. Baker Gait analysis methods in rehabilitation , 2006, Journal of NeuroEngineering and Rehabilitation.

[17]  Jaime Prat Pastor,et al.  Development of a hinge compatible with the kinematics of the knee joint , 2007, Prosthetics and orthotics international.

[18]  F. Fuss Anatomy of the cruciate ligaments and their function in extension and flexion of the human knee joint. , 1989, The American journal of anatomy.

[19]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[20]  N. Zheng,et al.  Alterations in three-dimensional joint kinematics of anterior cruciate ligament-deficient and -reconstructed knees during walking. , 2010, Clinical biomechanics.

[21]  Guang-Zhong Yang,et al.  Towards Pervasive Gait Analysis for Medicine with Wearable Sensors: A Systematic Review for Clinicians and Medical Researchers. , 2016, IEEE journal of biomedical and health informatics.

[22]  Barbara L Shay,et al.  Correcting waveform bias using principal component analysis: Applications in multicentre motion analysis studies. , 2017, Gait & posture.

[23]  Kate Button,et al.  Inertial Measurement Units for Clinical Movement Analysis: Reliability and Concurrent Validity , 2018, Sensors.

[24]  Nigel H. Lovell,et al.  Wearable pendant device monitoring using new wavelet-based methods shows daily life and laboratory gaits are different , 2015, Medical & Biological Engineering & Computing.

[25]  Sheldon R Simon,et al.  Quantification of human motion: gait analysis-benefits and limitations to its application to clinical problems. , 2004, Journal of biomechanics.

[26]  W. A. Hodge,et al.  Knee kinematics and kinetics during locomotor activities of daily living in subjects with knee arthroplasty and in healthy control subjects. , 1993, Physical therapy.

[27]  V. Pomeroy,et al.  A comparison of knee kinematic characteristics of stroke patients and age-matched healthy volunteers , 2003, Clinical rehabilitation.

[28]  A. Cappello,et al.  A new formulation of the coefficient of multiple correlation to assess the similarity of waveforms measured synchronously by different motion analysis protocols. , 2010, Gait & posture.

[29]  S. Piazza,et al.  Measurement of the screw-home motion of the knee is sensitive to errors in axis alignment. , 2000, Journal of biomechanics.

[30]  Pietro Picerno,et al.  25 years of lower limb joint kinematics by using inertial and magnetic sensors: A review of methodological approaches. , 2017, Gait & posture.

[31]  T. Andriacchi,et al.  Longitudinal changes in knee gait mechanics between 2 and 8 years after anterior cruciate ligament reconstruction , 2018, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[32]  Christian A. Clermont,et al.  New Considerations for Collecting Biomechanical Data Using Wearable Sensors: The Effect of Different Running Environments , 2020, Frontiers in Bioengineering and Biotechnology.