Ultrasound in dermatology – basic principles and applications

Ultrasound is widely used in general clinical medicine for non‐invasive internal imaging. Over the last twenty years, technological advances have enabled the application of high‐resolution ultrasonic imaging to the skin. Equipment and hardware is now available to produce cross‐section images and three‐dimensional reconstructions of selected skin segments. Resolution in vivo is not comparable to light microscopy but continues to improve with superior transducer designs. Skin ultrasonography has been reliably employed as an imaging modality in experimental designs, its quantifiable parameters being a distinct advantage. In particular, increased water content of the upper dermis, as occurs in inflammatory conditions or as a result of photodamage, can be demonstrated clearly as an echo‐poor zone. Thus, the future of high‐resolution ultrasound (HRU) may reside in its experimental role in monitoring inflammatory or photodamage processes in response to novel treatments. With regard to skin tumours, HRU reliably measures tumour thickness and also holds promise as a differentiator between seborrhoeic keratoses vs. melanoma and benign naevi vs. melanoma. While largely an experimental tool, the potential as an accurate, quantitative and reliable diagnostic and monitoring aid, merits further attention with an emphasis on clinical outcome measures.

[1]  P. Payne,et al.  Comparison of xeroradiographic and ultrasound detection of corticosteroid induced dermal thinning. , 1981, The Journal of investigative dermatology.

[2]  J C Bamber,et al.  High frequency, high resolution B‐scan ultrasound in the assessment of skin tumours , 1993, The British journal of dermatology.

[3]  R J Ott,et al.  Spectrophotometric assessment of pigmented skin lesions: methods and feature selection for evaluation of diagnostic performance. , 2000, Physics in medicine and biology.

[4]  D. Miller,et al.  Determining skin thickness with pulsed ultra sound. , 1979, The Journal of investigative dermatology.

[5]  W. Sterry,et al.  Ultrasound‐guided fine‐needle aspiration cytology in the early detection of melanoma metastases , 2000, Cancer.

[6]  J. Serup,et al.  Ultrasound for assessment of allergic and irritant patch test reactions , 1987, Contact dermatitis.

[7]  B. Querleux,et al.  Assessment of aging of the human skin by in vivo ultrasonic imaging. , 1989, The Journal of investigative dermatology.

[8]  D. Black,et al.  Comparison of techniques for the non‐invasive assessment of skin tumours , 1987, Clinical and experimental dermatology.

[9]  M. Schmid-Wendtner,et al.  Improved differentiation of benign and malignant lymphadenopathy in patients with cutaneous melanoma by contrast-enhanced color Doppler sonography. , 2002, Archives of dermatology.

[10]  H. Pehamberger,et al.  Sonography versus palpation in the detection of regional lymph-node metastases in patients with malignant melanoma. , 1990, European journal of cancer.

[11]  M. Gniadecka,et al.  Assessment of dermal water by high‐frequency ultrasound: comparative studies with nuclear magnetic resonance , 1996, The British journal of dermatology.

[12]  S. Seidenari,et al.  Ultrasound B scanning with image analysis for assessment of allergic patch test reactions , 1991, Contact dermatitis.

[13]  F. Foster,et al.  The use of high-frequency ultrasound as a method of assessing the severity of a plaque of psoriasis. , 1996, Archives of dermatology.

[14]  I. Yamamoto,et al.  Ultrastructure of adenoid cystic carcinoma , 1970, Cancer.

[15]  Peter J. Fish,et al.  Lesion classification using skin patterning , 2000, Skin research and technology : official journal of International Society for Bioengineering and the Skin (ISBS) [and] International Society for Digital Imaging of Skin (ISDIS) [and] International Society for Skin Imaging.

[16]  C Edwards,et al.  The use of A‐scan ultrasound in the assessment of small skin tumours , 1989, The British journal of dermatology.

[17]  J. Serup,et al.  Non‐invasive quantification of psoriasis plaques–measurement of skin thickness with 15 mHz pulsed ultrasound , 1984, Clinical and experimental dermatology.

[18]  J. Rabinowitz,et al.  Ultrasonography and computed tomography of inflammatory abdominal wall lesions. , 1982, Radiology.

[19]  J C Bamber,et al.  Differentiation of common benign pigmented skin lesions from melanoma by high‐resolution ultrasound , 2000, The British journal of dermatology.

[20]  D J Coleman,et al.  Computerized ultrasonic tissue characterization of ocular tumors. , 1983, American journal of ophthalmology.

[21]  G. Ott,et al.  Lymphadenopathy: differentiation of benign from malignant disease--color Doppler US assessment of intranodal angioarchitecture. , 1998, Radiology.

[22]  Y. Takema,et al.  Dermal fluid translocation is an important determinant of the diurnal variation in human skin thickness , 2001, The British journal of dermatology.

[23]  Z. Yen,et al.  Ultrasonographic screening of clinically-suspected necrotizing fasciitis. , 2002, Academic emergency medicine : official journal of the Society for Academic Emergency Medicine.

[24]  M. Gniadecka Localization of dermal edema in lipodermatosclerosis, lymphedema, and cardiac insufficiency. High-frequency ultrasound examination of intradermal echogenicity. , 1996, Journal of the American Academy of Dermatology.

[25]  D. A. Christopher,et al.  Advances in ultrasound biomicroscopy. , 2000, Ultrasound in medicine & biology.

[26]  M. Gniadecka Dermal oedema in lipodermatosclerosis: distribution, effects of posture and compressive theraphy evaluated by high-frequency ultrasonography. , 1995, Acta dermato-venereologica.

[27]  S. Capewell,et al.  Purpura and dermal thinning associated with high dose inhaled corticosteroids. , 1990, BMJ.