Effects of torsional movements in refractive procedures.

UNLABELLED Using PubMed and our internal database, we extensively reviewed the literature on the history of measurement of torsional movements of the eye from 1963 to the present, focusing specifically on the implications of torsional measurement and compensation in corneal refractive and ocular surgery. Mean cyclotorsional movements observed in refractive surgery procedures have been reported to be around 3 degrees, which can be well controlled by the currently used technology. Torsional movements affect aberrations with a vectorial component (astigmatic procedures) more adversely. Currently available eye-registration technology provides an accuracy of ±1.5 degrees. The vectorial components of residual aberrations can be minimized by intentionally underplanning the refractive treatments. The gaps in our knowledge limit the precision in current surgical procedures due to imperfect cyclotorsion compensation. This review summarizes about the explored aspects of torsional movements in surgical applications and raises questions about the unexplored implications. FINANCIAL DISCLOSURE Dr. Arba Mosquera and Mr. Verma are employees of Schwind eye-tech-solutions GmbH and Co. KG.

[1]  Shiau Shing Phang,et al.  Investigating and developing a model for iris changes under varied lighting conditions , 2007 .

[2]  Samuel Arba Mosquera,et al.  The effect of static cyclotorsion compensation on refractive and visual outcomes using the Schwind Amaris laser platform for the correction of high astigmatism. , 2011, Contact lens & anterior eye : the journal of the British Contact Lens Association.

[3]  Mujtaba A. Qazi,et al.  Novel Objective Method for Comparing Ablation Centration With and Without Pupil Tracking Following Myopic Laser In Situ Keratomileusis Using the Bausch & Lomb Technolas 217A , 2009, Cornea.

[4]  T. Seiler,et al.  Q‐factor customized ablation profile for the correction of myopic astigmatism , 2006, Journal of cataract and refractive surgery.

[5]  Samuel Arba-Mosquera,et al.  Excimer laser correction of moderate to high astigmatism with a non‐wavefront‐guided aberration‐free ablation profile: Six‐month results , 2009, Journal of cataract and refractive surgery.

[6]  David R Williams,et al.  Effect of beam size on the expected benefit of customized laser refractive surgery. , 2003, Journal of refractive surgery.

[7]  S. Barbero,et al.  Optical response to LASIK surgery for myopia from total and corneal aberration measurements. , 2001, Investigative ophthalmology & visual science.

[8]  M. Mrochen,et al.  Wavefront‐optimized ablation profiles: Theoretical background , 2004, Journal of cataract and refractive surgery.

[9]  Stephan A Schruender,et al.  Intraoperative corneal topography for image registration. , 2002, Journal of refractive surgery.

[10]  John Chang,et al.  Cyclotorsion during laser in situ keratomileusis , 2008, Journal of cataract and refractive surgery.

[11]  Katsumi Aoki,et al.  Recent development of flow visualization , 2004, J. Vis..

[12]  H. Bains,et al.  Active cyclotorsion error correction during LASIK for myopia and myopic astigmatism with the NIDEK EC-5000 CX III laser. , 2007, Journal of refractive surgery.

[13]  R Becker,et al.  Use of preoperative assessment of positionally induced cyclotorsion: a video-oculographic study , 2004, British Journal of Ophthalmology.

[14]  S. Kang,et al.  New axis-marking method for a toric intraocular lens: mapping method. , 2011, Journal of refractive surgery.

[15]  Jorge Ares,et al.  Direct transformation of Zernike eye aberration coefficients between scaled, rotated, and/or displaced pupils. , 2006, Journal of the Optical Society of America. A, Optics, image science, and vision.

[16]  D. Koch,et al.  Detection of static cyclotorsion and compensation for dynamic cyclotorsion in laser in situ keratomileusis , 2010, Journal of cataract and refractive surgery.

[17]  Junzhong Liang,et al.  Objective measurement of wave aberrations of the human eye with the use of a Hartmann-Shack wave-front sensor. , 1994, Journal of the Optical Society of America. A, Optics, image science, and vision.

[18]  David Huang,et al.  Spot size and quality of scanning laser correction of higher‐order wavefront aberrations , 2002, Journal of cataract and refractive surgery.

[19]  Michael Mrochen,et al.  Limitations of pupil tracking in refractive surgery: systematic error in determination of corneal locations. , 2004, Journal of refractive surgery.

[20]  A. Bradley,et al.  Statistical variation of aberration structure and image quality in a normal population of healthy eyes. , 2002, Journal of the Optical Society of America. A, Optics, image science, and vision.

[21]  E. M. Smith,et al.  Comparison of astigmatic axis in the seated and supine positions. , 1994, Journal of refractive and corneal surgery.

[22]  Oliver Findl,et al.  Evaluation of 4 corneal astigmatic marking methods , 2012, Journal of cataract and refractive surgery.

[23]  M. Moshirfar,et al.  Effect of iris registration on outcomes of LASIK for myopia with the VISX CustomVue platform. , 2009, Journal of refractive surgery.

[24]  John M Graether,et al.  Simplified system of marking the cornea for a toric intraocular lens , 2009, Journal of cataract and refractive surgery.

[25]  Charles E Campbell A New Method for Describing the Aberrations of the Eye Using Zernike Polynomials , 2003, Optometry and vision science : official publication of the American Academy of Optometry.

[26]  A. Agarwal,et al.  Predictive factor analysis for successful performance of iris recognition-assisted dynamic rotational eye tracking during laser in situ keratomileusis. , 2010, American journal of ophthalmology.

[27]  T. Seiler,et al.  Maximum permissible lateral decentration in aberration‐sensing and wavefront‐guided corneal ablation , 2003, Journal of cataract and refractive surgery.

[28]  Dimitri A Chernyak,et al.  From wavefront device to laser: an alignment method for complete registration of the ablation to the cornea. , 2005, Journal of refractive surgery.

[29]  K. Shimizu,et al.  Clinical Evaluation of Accuracy of Horizontal Meridian Limbal Marking , 2013, Optometry and vision science : official publication of the American Academy of Optometry.

[30]  S. A. Comastri,et al.  Zernike expansion coefficients: rescaling and decentring for different pupils and evaluation of corneal aberrations , 2007 .

[31]  Roger F Steinert,et al.  Rotational malposition during laser in situ keratomileusis. , 2002, American journal of ophthalmology.

[32]  Soosan Jacob,et al.  Surface ablation with iris recognition and dynamic rotational eye tracking-based tissue saving treatment with the Technolas 217z excimer laser. , 2010, Journal of refractive surgery.

[33]  David R Williams,et al.  Neural compensation for the eye's optical aberrations. , 2004, Journal of vision.

[34]  Samuel Arba-Mosquera,et al.  Three-month Clinical Outcomes With Static and Dynamic Cyclotorsion Correction Using the SCHWIND AMARIS , 2011, Cornea.

[35]  K. Tsubota,et al.  Detection of cyclotorsional rotation during excimer laser ablation in LASIK. , 2007, Journal of refractive surgery.

[36]  Luís A. Alexandre,et al.  Iris surface deformation and normalization , 2013, 2013 13th International Symposium on Communications and Information Technologies (ISCIT).

[37]  J. Schwiegerling,et al.  Eye movement during laser in situ keratomileusis. , 2000, Journal of cataract and refractive surgery.

[38]  D. Azar,et al.  Outcome of corneal and laser astigmatic axis alignment in photoastigmatic refractive keratectomy , 2000, Journal of cataract and refractive surgery.

[39]  F. Zernike Diffraction theory of the knife-edge test and its improved form, the phase-contrast method , 1934 .

[40]  Harold E Bedell,et al.  Optimizing wavefront-guided corrections for highly aberrated eyes in the presence of registration uncertainty. , 2013, Journal of vision.

[41]  Y. Tsai,et al.  Ablation centration after active eye-tracker-assisted photorefractive keratectomy and laser in situ keratomileusis. , 2000, Journal of cataract and refractive surgery.

[42]  RENZO MATTIOLI,et al.  Corneal Geometry Reconstruction with the Keratron Videokeratographer , 1997, Optometry and vision science : official publication of the American Academy of Optometry.

[43]  M. Arbelaez,et al.  Use of a six-dimensional eye-tracker in corneal laser refractive surgery with the SCHWIND AMARIS TotalTech laser. , 2011, Journal of refractive surgery.

[44]  David R Williams,et al.  Neural compensation for the best aberration correction. , 2007, Journal of vision.

[45]  Samuel Arba-Mosquera,et al.  Clinical effects of pure cyclotorsional errors during refractive surgery. , 2008, Investigative ophthalmology & visual science.

[46]  L. Thibos,et al.  Standards for reporting the optical aberrations of eyes. , 2002, Journal of refractive surgery.

[47]  S. Marcos,et al.  Aberrations and visual performance following standard laser vision correction. , 2001, Journal of refractive surgery.

[48]  Y. Tano,et al.  Using a reference point and videokeratography for intraoperative identification of astigmatism axis , 1997, Journal of cataract and refractive surgery.

[49]  F. Hu,et al.  Manual limbal markings versus iris‐registration software for correction of myopic astigmatism by laser in situ keratomileusis , 2010, Journal of cataract and refractive surgery.

[50]  L. Lundström,et al.  Transformation of Zernike coefficients: scaled, translated, and rotated wavefronts with circular and elliptical pupils. , 2007, Journal of the Optical Society of America. A, Optics, image science, and vision.

[51]  D R Williams,et al.  Effect of rotation and translation on the expected benefit of an ideal method to correct the eye's higher-order aberrations. , 2001, Journal of the Optical Society of America. A, Optics, image science, and vision.

[52]  I. Lipshitz Thirty-four challenges to meet before excimer laser technology can achieve super vision. , 2002, Journal of refractive surgery.

[53]  C. Joo,et al.  Ocular cyclotorsion according to body position and flap creation before laser in situ keratomileusis , 2008, Journal of cataract and refractive surgery.

[54]  R H Eikelboom,et al.  Determining the accuracy of an eye tracking system for laser refractive surgery. , 2000, Journal of refractive surgery.

[55]  A. Lucena,et al.  Cyclotorsion measurement in laser refractive surgery. , 2013, Arquivos brasileiros de oftalmologia.

[56]  M. Mrochen,et al.  Wavefront aberrations in eyes with decentered ablations , 2009, Journal of cataract and refractive surgery.

[57]  Stephen A Burns,et al.  Pupil location under mesopic, photopic, and pharmacologically dilated conditions. , 2002, Investigative ophthalmology & visual science.

[58]  Irmingard M Neuhann,et al.  Static and dynamic rotational eye tracking during LASIK treatment of myopic astigmatism with the Zyoptix laser platform and Advanced Control Eye Tracker. , 2010, Journal of refractive surgery.

[59]  Jason E Stahl,et al.  Ocular cyclotorsion during customized laser ablation. , 2005, Journal of refractive surgery.

[60]  P G Gobbi,et al.  Automatic eye tracker for excimer laser photorefractive keratectomy. , 1995, Journal of refractive surgery.

[61]  Choun-Ki Joo,et al.  Measurement of Pupil Centroid Shift and Cyclotorsional Displacement Using Iris Registration , 2009, Ophthalmologica.

[62]  Keith Dillon Bilinear wavefront transformation. , 2009, Journal of the Optical Society of America. A, Optics, image science, and vision.

[63]  Mounir A. Khalifa,et al.  Iris registration in wavefront‐guided LASIK to correct mixed astigmatism , 2009, Journal of cataract and refractive surgery.

[64]  D. Koch,et al.  Residual higher‐order aberrations caused by clinically measured cyclotorsional misalignment or decentration during wavefront‐guided excimer laser corneal ablation , 2008, Journal of cataract and refractive surgery.

[65]  D L Guyton,et al.  Centering corneal surgical procedures. , 1987, American journal of ophthalmology.

[66]  R. Crone Human cyclofusional response. , 1971, Vision research.

[67]  David Williams,et al.  Surgeon offsets and dynamic eye movements in laser refractive surgery , 2005, Journal of cataract and refractive surgery.

[68]  Theo Seiler,et al.  Correlation between corneal and total wavefront aberrations in myopic eyes. , 2003, Journal of refractive surgery.

[69]  S. Bará,et al.  Positioning tolerances for phase plates compensating aberrations of the human eye. , 2000, Applied optics.

[70]  A Harden,et al.  Cyclotorsion: a new method of measurement. , 1974, Proceedings of the Royal Society of Medicine.

[71]  Jorge L Alió,et al.  Topography-guided laser in situ keratomileusis (TOPOLINK) to correct irregular astigmatism after previous refractive surgery. , 2003, Journal of refractive surgery.

[72]  Dexin Zhang,et al.  Efficient iris recognition by characterizing key local variations , 2004, IEEE Transactions on Image Processing.

[73]  A. Bradley,et al.  Accuracy and precision of objective refraction from wavefront aberrations. , 2004, Journal of vision.

[74]  D. Chernyak,et al.  Cyclotorsional eye motion occurring between wavefront measurement and refractive surgery , 2004, Journal of cataract and refractive surgery.

[75]  Lingyun Cheng,et al.  Visual outcomes after wavefront‐guided laser in situ keratomileusis with and without iris registration , 2008, Journal of cataract and refractive surgery.

[76]  A. Agarwal,et al.  Comparison of laser in situ keratomileusis for myopic astigmatism without iris registration, with iris registration, and with iris registration–assisted dynamic rotational eye tracking , 2011, Journal of cataract and refractive surgery.

[77]  Michael Mrochen,et al.  Simulation of eye-tracker latency, spot size, and ablation pulse depth on the correction of higher order wavefront aberrations with scanning spot laser systems. , 2005, Journal of refractive surgery.

[78]  M. Tjon-Fo-Sang,et al.  Cyclotorsion: A possible cause of residual astigmatism in refractive surgery , 2002, Journal of cataract and refractive surgery.

[79]  J. Talamo,et al.  Cyclotorsion in the seated and supine patient , 1995, Journal of cataract and refractive surgery.

[80]  Theo Seiler,et al.  Clinical results of wavefront‐guided laser in situ keratomileusis 3 months after surgery , 2001, Journal of cataract and refractive surgery.

[81]  Jehn-Yu Huang,et al.  Pupil centroid shift and cyclotorsion in bilateral wavefront-guided laser refractive surgery and the correlation between both eyes. , 2013, Journal of the Formosan Medical Association = Taiwan yi zhi.

[82]  T. Seiler,et al.  Maximum permissible torsional misalignment in aberration‐sensing and wavefront‐guided corneal ablation , 2004, Journal of cataract and refractive surgery.

[83]  Justo Arines,et al.  Translational and rotational pupil tracking by use of wavefront aberration data and image registration techniques. , 2006, Optics letters.

[84]  Hugh Davson Physiology of the Eye , 1951 .

[86]  Samuel Arba-Mosquera,et al.  Analysis of the effects of Eye-Tracker performance on the pulse positioning errors during refractive surgery , 2012 .

[87]  Klaus Schmid,et al.  Intraoperative cyclorotation and pupil centroid shift during LASIK and PRK. , 2012, Journal of refractive surgery.