On empirical methods to determine scatter factors for irregular MLC shaped beams.

Multileaf collimators (MLCs) are in clinical use for more than a decade and are a well accepted tool in radiotherapy. For almost each MLC design different empirical or semianalytical methods have been presented for calculating output ratios in air for irregularly shaped beams. However, until now no clear recommendations have been given on how to handle irregular fields shaped by multileaf collimators for independent monitor unit (MU) verification. The present article compares different empirical methods, which have been proposed for independent MU verification, to determine (1) output ratios in air (Sc) and (2) phantom scatter factors (Sp) for irregular MLC shaped fields. Ten dedicated field shapes were applied to five different types of MLCs (Elekta, Siemens, Varian, Scanditronix, General Electric). All calculations based on empirical relations were compared with measurements and with calculations performed by a treatment planning system with a fluence based algorithm. For most irregular MLC shaped beams output ratios in air could be adequately modeled with an accuracy of about 1%-1.5% applying a method based on the open field aperture defined by the leaf and jaw setting combined with the equivalent square formula suggested by Vadash and Bjärngard [P. Vadash and B. E. Bjärngard, Med. Phys. 20, 733-734 (1993)]. The accuracy of this approach strongly depends on the inherent head scatter characteristics of the accelerator in use and on the irregular field under consideration. Deviations of up to 3% were obtained for fields where leaves obscure central parts of the flattening filter. Simple equivalent square methods for Sp calculations in irregular fields did not provide acceptable results (deviations mostly >3%). Sp values derived from Clarkson integration, based on published tables of phantom scatter correction factors, showed the same accuracy level as calculations performed using a pencil beam algorithm of a treatment planning system (in a homogeneous media). The separation of head scatter and phantom scatter contributions is strongly recommended for irregular MLC shaped beams as both contributions have different factors of influence. With rather simple methods Sc and Sp can be determined for independent MU calculation with an accuracy better than 1.5% for most clinical situations encountered in conformal radiotherapy.

[1]  A Ahnesjö,et al.  Analytic modeling of photon scatter from flattening filters in photon therapy beams. , 1994, Medical physics.

[2]  B. Bjärngard,et al.  An equivalent-square formula for head-scatter factors. , 1993, Medical physics.

[3]  M. Al-Ghazi,et al.  A practical method for the calculation of multileaf collimator shaped fields output factors. , 1999, Medical physics.

[4]  D. Georg,et al.  Dosimetric comparison of an integrated multileaf-collimator versus a conventional collimator. , 1997, Physics in medicine and biology.

[5]  J. R. Clarkson,et al.  A Note on Depth Doses in Fields of Irregular Shape , 1941 .

[6]  P. Biggs,et al.  Comparison of the penumbra between focused and nondivergent blocks--implications for multileaf collimators. , 1991, Medical physics.

[7]  James M. Galvin,et al.  CHARACTERIZATION OF A MULTILEAF COLLIMATOR SYSTEM , 1993 .

[8]  A. Ahnesjö,et al.  A pencil beam model for photon dose calculation. , 1992, Medical physics.

[9]  S M Morrill,et al.  MLC dosimetric characteristics for small field and IMRT applications. , 2003, Medical physics.

[10]  P. Storchi,et al.  A table of phantom scatter factors of photon beams as a function of the quality index and field size. , 1996, Physics in medicine and biology.

[11]  M. Alber,et al.  Optimization of intensity modulated radiotherapy under constraints for static and dynamic MLC delivery. , 2001, Physics in medicine and biology.

[12]  A Ahnesjö,et al.  Collimator scatter in photon therapy beams. , 1995, Medical physics.

[13]  T LoSasso,et al.  The use of a multi-leaf collimator for conformal radiotherapy of carcinomas of the prostate and nasopharynx. , 1993, International journal of radiation oncology, biology, physics.

[14]  J M Wilkinson,et al.  Head scatter modelling for irregular field shaping and beam intensity modulation. , 1997, Physics in medicine and biology.

[15]  Mikael Karlsson,et al.  A widely tested model for head scatter influence on photon beam output. , 2003, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[16]  T Knöös,et al.  Application of the convolution method for calculation of output factors for therapy photon beams. , 1992, Medical physics.

[17]  M A Astrahan,et al.  Output factor constituents of a high-energy photon beam. , 1988, Medical physics.

[18]  J Duan,et al.  Effect of multileaf collimator leaf width on physical dose distributions in the treatment of CNS and head and neck neoplasms with intensity modulated radiation therapy. , 2002, Medical physics.

[19]  D. Georg,et al.  A formalism to calculate the output ratio in a mini-phantom for a GE multileaf collimator. , 1997, Physics in medicine and biology.

[20]  Karl Otto,et al.  Enhancement of IMRT delivery through MLC rotation. , 2002, Physics in medicine and biology.

[21]  Lei Xing,et al.  Incorporating leaf transmission and head scatter corrections into step-and-shoot leaf sequences for IMRT. , 2003, International journal of radiation oncology, biology, physics.

[22]  A L Boyer,et al.  Clinical dosimetry for implementation of a multileaf collimator. , 1992, Medical physics.

[23]  P. C. Williams,et al.  The design and performance characteristics of a multileaf collimator , 1994, Physics in medicine and biology.

[24]  A Brahme,et al.  Design principles and clinical possibilities with a new generation of radiation therapy equipment. A review. , 1987, Acta oncologica.

[25]  D A Low,et al.  Clinical implementation of a commercial multileaf collimator: dosimetry, networking, simulation, and quality assurance. , 1995, International journal of radiation oncology, biology, physics.

[26]  T D STERLING,et al.  AUTOMATION OF RADIATION TREATMENT PLANNING. IV. DERIVATION OF A MATHEMATICAL EXPRESSION FOR THE PER CENT DEPTH DOSE SURFACE OF COBALT 60 BEAMS AND VISUALISATION OF MULTIPLE FIELD DOSE DISTRIBUTIONS. , 1964, The British journal of radiology.

[27]  J. Palta,et al.  Dosimetric considerations for a multileaf collimator system. , 1996, Medical physics.

[28]  A. Boyer,et al.  Dose distributions of x-ray fields as shaped with multileaf collimators. , 1992, Physics in medicine and biology.

[29]  P. Dunscombe,et al.  On the field-size dependence of relative output from a linear accelerator. , 1992, Medical physics.

[30]  T E Schultheiss,et al.  Beam characteristics of a retrofitted double-focused multileaf collimator. , 1998, Medical physics.