Reliability of quadriceps surface electromyography measurements is improved by two vs. single site recordings

PurposeThe reliability of surface electromyography (sEMG) is typically modest even with rigorous methods, and therefore further improvements in sEMG reliability are desirable. This study compared the between-session reliability (both within participant absolute reliability and between-participant relative reliability) of sEMG amplitude from single vs. average of two distinct recording sites, for individual muscle (IM) and whole quadriceps (WQ) measures during voluntary and evoked contractions.MethodsHealthy males (n = 20) performed unilateral isometric knee extension contractions: voluntary maximum and submaximum (60%), as well as evoked twitch contractions on two separate days. sEMG was recorded from two distinct sites on each superficial quadriceps muscle.ResultsAveraging two recording sites vs. using single site measures improved reliability for IM and WQ measurements during voluntary (16–26% reduction in within-participant coefficient of variation, CVW) and evoked contractions (40–56% reduction in CVW).ConclusionsFor sEMG measurements from large muscles, averaging the recording of two distinct sites is recommended as it improves within-participant reliability. This improved sensitivity has application to clinical and research measurement of sEMG amplitude.

[1]  Alain Martin,et al.  Assessment of the reliability of central and peripheral fatigue after sustained maximal voluntary contraction of the quadriceps muscle , 2007, Muscle & nerve.

[2]  Lars Arendt-Nielsen,et al.  Experimental muscle pain modulates muscle activity and work performance differently during high and low precision use of a computer mouse , 2000, European Journal of Applied Physiology.

[3]  R. Lamberts,et al.  Alternative methods of normalising EMG during running. , 2011, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[4]  J Scurr,et al.  An assessment of the reliability and standardisation of tests used to elicit reference muscular actions for electromyographical normalisation. , 2010, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[5]  J. F. Yang,et al.  Electromyography reliability in maximal and submaximal isometric contractions. , 1983, Archives of physical medicine and rehabilitation.

[6]  D. F. Percy,et al.  Muscle fatigue in chronic fatigue syndrome/myalgic encephalomyelitis (CFS/ME) and its response to a manual therapeutic approach: A pilot study , 2011 .

[7]  Gregory S. Rash,et al.  Electromyography Fundamentals , 1999 .

[8]  M. Lambert,et al.  Alternative methods of normalising EMG during cycling. , 2010, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[9]  C. Grimbergen,et al.  Investigation into the origin of the noise of surface electrodes , 2002, Medical and Biological Engineering and Computing.

[10]  B. Ainsworth,et al.  International physical activity questionnaire: 12-country reliability and validity. , 2003, Medicine and science in sports and exercise.

[11]  B. Freriks,et al.  Development of recommendations for SEMG sensors and sensor placement procedures. , 2000, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[12]  J. Folland,et al.  Nitrate supplementation enhances the contractile properties of human skeletal muscle. , 2014, Medicine and science in sports and exercise.

[13]  K. Cureton,et al.  Effects of concentric and eccentric training on muscle strength, cross-sectional area, and neural activation. , 1996, Journal of applied physiology.

[14]  Carlo J. De Luca,et al.  The Use of Surface Electromyography in Biomechanics , 1997 .

[15]  A. Burden How should we normalize electromyograms obtained from healthy participants? What we have learned from over 25 years of research. , 2010, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[16]  J. Helgerud,et al.  Enhanced neural drive after maximal strength training in multiple sclerosis patients , 2010, European Journal of Applied Physiology.

[17]  S. Siegel,et al.  Nonparametric Statistics for the Behavioral Sciences , 2022, The SAGE Encyclopedia of Research Design.

[18]  Luke R. Garceau,et al.  Reliability of Surface Electromyography During Maximal Voluntary Isometric Contractions, Jump Landings, and Cutting , 2010, Journal of strength and conditioning research.

[19]  Seward B. Rutkove,et al.  Introduction to Volume Conduction , 2007 .

[20]  Carlo J De Luca,et al.  Inter-electrode spacing of surface EMG sensors: reduction of crosstalk contamination during voluntary contractions. , 2012, Journal of biomechanics.

[21]  P. Hodges,et al.  Why do some patients keep hurting their back? Evidence of ongoing back muscle dysfunction during remission from recurrent back pain , 2009, PAIN®.

[22]  M. Garwicz,et al.  Altered movement patterns and muscular activity during single and double leg squats in individuals with anterior cruciate ligament injury , 2015, BMC Musculoskeletal Disorders.

[23]  J. Cram,et al.  Effects of skin preparation on data collected using an EMG muscle-scanning procedure , 1989, Biofeedback and self-regulation.

[24]  Ricci Hannah,et al.  Reliability of neuromuscular measurements during explosive isometric contractions, with special reference to electromyography normalization techniques , 2012, Muscle & nerve.

[25]  W J Kraemer,et al.  Changes in muscle morphology, electromyographic activity, and force production characteristics during progressive strength training in young and older men. , 1998, The journals of gerontology. Series A, Biological sciences and medical sciences.

[26]  T. G. Balshaw,et al.  Evaluation of electromyography normalisation methods for the back squat. , 2012, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[27]  T. G. Balshaw,et al.  Training-specific functional, neural, and hypertrophic adaptations to explosive- vs. sustained-contraction strength training. , 2016, Journal of applied physiology.

[28]  Seward B. Rutkove,et al.  The clinical neurophysiology primer , 2007 .

[29]  I. Tarkka,et al.  Analysis of surface EMG signal morphology in Parkinson's disease , 2007, Physiological measurement.

[30]  G. Melchiorri,et al.  A method for positioning electrodes during surface EMG recordings in lower limb muscles , 2004, Journal of Neuroscience Methods.

[31]  Isabelle Rogowski,et al.  Reliability of EMG normalisation methods for upper-limb muscles , 2013, Journal of sports sciences.

[32]  Cara E Stepp,et al.  Surface electromyography for speech and swallowing systems: measurement, analysis, and interpretation. , 2012, Journal of speech, language, and hearing research : JSLHR.

[33]  J. Folland,et al.  Task‐specific neural adaptations to isoinertial resistance training , 2015, Scandinavian journal of medicine & science in sports.

[34]  G. Howatson,et al.  Neuromuscular response differences to power vs strength back squat exercise in elite athletes , 2015, Scandinavian journal of medicine & science in sports.

[35]  J J Eng,et al.  Reliability of surface EMG during sustained contractions of the quadriceps. , 2005, Journal of electromyography and kinesiology : official journal of the International Society of Electrophysiological Kinesiology.

[36]  E. Simonsen,et al.  Neural adaptation to resistance training: changes in evoked V-wave and H-reflex responses. , 2002, Journal of applied physiology.

[37]  Alain Martin,et al.  Electromyostimulation training effects on neural drive and muscle architecture. , 2005, Medicine and science in sports and exercise.

[38]  Dario Farina,et al.  The extraction of neural strategies from the surface EMG: an update. , 2014, Journal of applied physiology.

[39]  D. Hinkle,et al.  Applied statistics for the behavioral sciences , 1979 .

[40]  B. Phillips,et al.  Gait and balance impairment in early multiple sclerosis in the absence of clinical disability , 2006, Multiple sclerosis.

[41]  Maarten J. IJzerman,et al.  Cervical Muscle Dysfunction in Chronic Whiplash-Associated Disorder Grade 2: The Relevance of the Trauma , 2002, Spine.

[42]  Jacques Duchateau,et al.  Rate of force development: physiological and methodological considerations , 2016, European Journal of Applied Physiology.

[43]  Prolonged infrapatellar tendon vibration does not influence quadriceps maximal or explosive isometric force production in man , 2014, European Journal of Applied Physiology.