Correction of Lenke 5 Adolescent Idiopathic Scoliosis Using Pedicle Screw Instrumentation: Does Implant Density Influence the Correction?

Study Design. A single-center, retrospective study of 39 consecutive patients with Lenke 5 adolescent idiopathic scoliosis (AIS), all operated by a single surgeon using identical surgical technique and type of instrumentation (pedicle screws). Objective. The objective of this study is to evaluate the effect of implant density on coronal and sagittal correction in the treatment of Lenke 5 AIS. Summary of Background Data. There is an increasing trend in the use of pedicle screws in spinal corrective surgery. It is reported that decreased numbers of pedicle screws (low screw density) have no effects on the clinical outcomes for patients with Lenke 1 AIS. However, no previous studies have investigated the effects of reduced density of screw implantation on coronal correction and sagittal lumbar lordosis in patients with Lenke 5 AIS. Methods. Thirty-nine consecutive patients with Lenke 5 AIS underwent single-stage posterior correction and instrumented spinal fusion with pedicle screw fixation between 2006 and 2010. The radiographs were analyzed before surgery, immediately after surgery, and at the 2-year follow-up. General information of patients was recorded. Pearson correlation analysis was used to analyze the correlation between implant density, coronal Cobb angle correction, and correction index (postoperative correction/preoperative curve flexibility). The relations between implant density and magnitude of coronal and sagittal curve correction were also investigated. Results. The mean patient age at the time of operation was 14.5 years. The mean preoperative lumbar curve of 48.5° ± 9.2° was corrected to 13.7° ± 7.2° (72% correction) at a 2-year follow-up. There was a significant correlation between implant density and curve correction (r = 0.43, P < 0.05). No correlation was detected between implant density and correction index (r = −0.21, P = 0.20), and there was also no correlation between implant density and magnitude of sagittal curve correction (r = 0.065, P = 0.693). Conclusion. Without curve flexibility taken into consideration, implant density is positively correlated with thoracolumbar or lumbar coronal Cobb curve correction. No significant correlation is found between screw density and correction index, if the effect of the flexibility was eliminated. There was no association between implant density and magnitude of sagittal curve correction before and after surgery. Level of Evidence: 4

[1]  R. Betz,et al.  Factors Involved in the Decision to Perform a Selective Versus Nonselective Fusion of Lenke 1B and 1C (King-Moe II) Curves in Adolescent Idiopathic Scoliosis , 2003, Spine.

[2]  L. Lenke,et al.  Classification of operative adolescent idiopathic scoliosis: treatment guidelines. , 2007, The Orthopedic clinics of North America.

[3]  C. K. Lee,et al.  Segmental Pedicle Screw Fixation in the Treatment of Thoracic Idiopathic Scoliosis , 1995, Spine.

[4]  M. Tezer,et al.  Comparative analysis of pedicle screw versus hybrid instrumentation in adolescent idiopathic scoliosis surgery , 2008, International Orthopaedics.

[5]  K. Cheung,et al.  Predictability of the fulcrum bending radiograph in scoliosis correction with alternate-level pedicle screw fixation. , 2010, The Journal of bone and joint surgery. American volume.

[6]  U. Liljenqvist,et al.  Sagittal balance of thoracic lordoscoliosis: anterior dual rod instrumentation versus posterior pedicle screw fixation , 2011, European Spine Journal.

[7]  L. Lenke,et al.  The Lenke Classification of Adolescent Idiopathic Scoliosis: How it Organizes Curve Patterns as a Template to Perform Selective Fusions of the Spine , 2003, Spine.

[8]  M. Millgram,et al.  Accuracy and Safety of Thoracic Pedicle Screw Placement in Spinal Deformities , 2005, Journal of spinal disorders & techniques.

[9]  Vincent Arlet,et al.  Complications of Pedicle Screw Fixation in Scoliosis Surgery: A Systematic Review , 2010, Spine.

[10]  L. Lenke,et al.  A Pedicle Screw Construct Gives an Enhanced Posterior Correction of Adolescent Idiopathic Scoliosis When Compared With Other Constructs: Myth or Reality , 2007, Spine.

[11]  C. K. Lee,et al.  Comparison of Cotrel-Dubousset pedicle screws and hooks in the treatment of idiopathic scoliosis , 1994, International Orthopaedics.

[12]  Amanda R Smith,et al.  Neural Complications in the Surgical Treatment of Adolescent Idiopathic Scoliosis , 2007, Spine.

[13]  R. Betz,et al.  Correlation of Scoliosis Curve Correction With the Number and Type of Fixation Anchors , 2009, Spine.

[14]  L. Lenke,et al.  Anterior/Posterior Spinal Instrumentation Versus Posterior Instrumentation Alone for the Treatment of Adolescent Idiopathic Scoliotic Curves More Than 90° , 2006, Spine.

[15]  Xiaodong Zhu,et al.  Coronal and Sagittal Plane Correction in Patients With Lenke 1 Adolescent Idiopathic Scoliosis: A Comparison of Consecutive Versus Interval Pedicle Screw Placement , 2009, Journal of spinal disorders & techniques.

[16]  H. Hashidate,et al.  Accuracy of Multilevel Registration in Image-Guided Pedicle Screw Insertion for Adolescent Idiopathic Scoliosis , 2010, Spine.

[17]  Samuel K. Cho,et al.  Comparative Analysis of Pedicle Screw Versus Hybrid Instrumentation in Posterior Spinal Fusion of Adolescent Idiopathic Scoliosis , 2004, Spine.

[18]  H. Nakashima,et al.  Comparison of the Percutaneous Screw Placement Precision of Isocentric C-arm 3-dimensional Fluoroscopy-navigated Pedicle Screw Implantation and Conventional Fluoroscopy Method With Minimally Invasive Surgery , 2009, Journal of spinal disorders & techniques.

[19]  John J Carbone,et al.  Fluoroscopically Assisted Pedicle Screw Fixation for Thoracic and Thoracolumbar Injuries: Technique and Short-Term Complications , 2003, Spine.

[20]  Sang Min Lee,et al.  Restoration of thoracic kyphosis in the hypokyphotic spine: a comparison between multiple-hook and segmental pedicle screw fixation in adolescent idiopathic scoliosis. , 1999, Journal of spinal disorders.