Minimum Fisher Tikhonov Regularization Adapted to Real-Time Tomography

Abstract Tomography inversion has been used routinely for processing outputs of plasma radiation diagnostics. Various tomographic algorithms have been developed, with those based on Tikhonov regularization being among the fastest while still providing reliable results. This paper presents a further speed optimization of the minimum Fisher Tikhonov regularization algorithm based on reducing iteration cycles used during the calculation. Ten to twentyfold speed gain is achieved compared to the original implementation. Robustness of the new method is demonstrated using both artificially generated data sets and real data from the soft X-ray diagnostics at the COMPASS tokamak. The advantage gained by the optimization is investigated in particular with respect to the possibility of real-time control of the plasma position; the option of impurity control is also discussed.

[1]  L. C. Ingesson,et al.  Chapter 7: Tomography Diagnostics: Bolometry and Soft-X-Ray Detection , 2008 .

[2]  J. Adamek,et al.  Status of the COMPASS tokamak and characterization of the first H-mode , 2015 .

[3]  Henrik Sjöstrand,et al.  Neural networks based neutron emissivity tomography at JET with real-time capabilities , 2010 .

[4]  J. Contributors,et al.  Tungsten transport in JET H-mode plasmas in hybrid scenario, experimental observations and modelling , 2014 .

[5]  Alfredo Pironti,et al.  Current, Position, and Shape Control in Tokamaks , 2011 .

[6]  Luo Jia-rong Review of the Equilibrium Fitting for Non-Circular Tokamak , 2002 .

[7]  A. Murari,et al.  Inversion Techniques in the Soft-X-Ray Tomography of Fusion Plasmas: Toward Real-Time Applications , 2010 .

[8]  M. Hron,et al.  Use of soft x-ray diagnostic on the COMPASS tokamak for investigations of sawteeth crash neighborhood and of plasma position using fast inversion methods. , 2014, The Review of scientific instruments.

[9]  P. J. Paris,et al.  X-ray tomography on the TCV tokamak , 1996 .

[10]  U. von Toussaint,et al.  Fast tomographic methods for the tokamak ISTTOK , 2008 .

[11]  P J Carvalho,et al.  Real-time plasma control based on the ISTTOK tomography diagnostic. , 2008, The Review of scientific instruments.

[12]  T. Pütterich,et al.  SXR tomography of tungsten radiation patterns with and without MHD , 2015 .

[13]  A. Murari,et al.  Modern numerical methods for plasma tomography optimisation , 2012 .

[14]  R. Guirlet,et al.  Impurity density derivation from bandpass soft x-ray tomography: applicability, perspectives and limitations , 2014 .

[15]  Ulrich Tautenhahn,et al.  Morozov's Discrepancy Principle under General Source Conditions , 2003 .

[16]  L. C. Ingesson,et al.  Soft X ray tomography during ELMs and impurity injection in JET , 1998 .