Use of STATCOM in wind farms with fixed-speed generators for grid code compliance

The increasing penetration of wind energy into power systems has pushed grid operators to set new requirements for this kind of generating plants in order to keep acceptable and reliable operation of the system. In addition to the low voltage ride through capability, wind farms are required to participate in voltage support, stability enhancement and power quality improvement. This paper presents a solution for wind farms with fixed-speed generators based on the use of STATCOM with braking resistor and additional series impedances, with an adequate control strategy. The focus is put on guaranteeing the grid code compliance when the wind farm faces an extensive series of grid disturbances.

[1]  M. H. J. Bollen,et al.  Impact of EV Battery Chargers on the Power Quality of Distribution Systems , 2002, IEEE Power Engineering Review.

[2]  D Ramirez,et al.  Low-Voltage Ride-Through Capability for Wind Generators Based on Dynamic Voltage Restorers , 2011, IEEE Transactions on Energy Conversion.

[3]  Math Bollen,et al.  Understanding Power Quality Problems: Voltage Sags and Interruptions , 1999 .

[4]  A.G. Jack,et al.  Fault Ride-Through of Large Wind Farms Using Series Dynamic Braking Resistors (March 2007) , 2007, IEEE Transactions on Power Systems.

[5]  Nicholas Jenkins,et al.  Application of a Static Reactive Power Compensator (STATCOM) and a Dynamic Braking Resistor (DBR) for the Stability Enhancement of a Large Wind Farm , 2003 .

[6]  D. Aouzellag,et al.  Static compensator for maintaining voltage stability of wind farm integration to a distribution network , 2010 .

[7]  M. Baran,et al.  STATCOM Impact Study on the Integration of a Large Wind Farm into a Weak Loop Power System , 2008, 2006 IEEE PES Power Systems Conference and Exposition.

[8]  R. P. Kumudini Devi,et al.  Effect of tuned unified power flow controller to mitigate the rotor speed instability of fixed-speed wind turbines , 2009 .

[9]  Massimo Bongiorno,et al.  Voltage Dip Mitigation Using Shunt-Connected Voltage Source Converter , 2007 .

[10]  Sergio Martínez,et al.  Educational tool for the implementation of electric drives control system with real time data exchange , 2009 .

[11]  Jon Are Suul,et al.  Low Voltage Ride Through of Wind Farms With Cage Generators: STATCOM Versus SVC , 2008, IEEE Transactions on Power Electronics.

[12]  Sarath B. Tennakoon,et al.  Evaluation of the suitability of a fixed speed wind turbine for large scale wind farms considering the new UK grid code , 2008 .

[13]  J. C. Ballesteros,et al.  Distributed generation system with PEM fuel cell for electrical power quality improvement , 2008 .

[14]  Thanh-Nam Le Kompensation schnell veränderlicher Blindströme eines Drehstromverbrauchers , 1989 .

[15]  A.P.M. Van den Bossche,et al.  Exact voltage unbalance assessment without phase measurements , 2005, IEEE Transactions on Power Systems.

[16]  Bin Wu,et al.  Comparison of Stabilization Methods for Fixed-Speed Wind Generator Systems , 2010, IEEE Transactions on Power Delivery.

[17]  Vigna Kumaran Ramachandaramurthy,et al.  Fault ride through and voltage regulation for grid connected wind turbine , 2011 .

[18]  G. C. Paap,et al.  Symmetrical components in the time domain and their application to power network calculations , 2000 .

[19]  J. Svensson,et al.  Practical Implementation of Delayed Signal Cancellation Method for Phase-Sequence Separation , 2007, IEEE Transactions on Power Delivery.