Optical design of a dynamic focus catheter for high-resolution endoscopic optical coherence tomography.

The optical system design of a dynamic focus endoscopic probe for optical coherence tomography is reported. The dynamic focus capability is based on a liquid lens technology that provides variable focus by changing its curvatures in response to an electric field variation. The effects of a cylindrical exit window present, in practice, for a catheter were accounted for. Degradation in image quality caused by this window was corrected to get diffraction limited imaging performance. As a result, the dynamically focusing catheter with a lateral resolution ranging from 4 to 6 mum through an approximately 5 mm imaging distance was designed without mechanically refocusing the system.

[1]  Matthew Brenner,et al.  In vivo endoscopic optical coherence tomography by use of a rotational microelectromechanical system probe. , 2004, Optics letters.

[2]  Kye-Sung Lee,et al.  A 5mm catheter for constant resolution probing in Fourier domain optical coherence endoscopy , 2007, SPIE BiOS.

[3]  B. Berge,et al.  Liquid lens technology: principle of electrowetting based lenses and applications to imaging , 2005, 18th IEEE International Conference on Micro Electro Mechanical Systems, 2005. MEMS 2005..

[4]  Eric Clarkson,et al.  Dispersion control with a Fourier-domain optical delay line in a fiber-optic imaging interferometer. , 2005, Applied optics.

[5]  W. Drexler,et al.  In vivo ultrahigh-resolution optical coherence tomography of mouse colon with an achromatized endoscope. , 2006, Journal of biomedical optics.

[6]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991 .

[7]  Angelika Unterhuber,et al.  An achromatized endoscope for ultrahigh-resolution optical coherence tomography , 2005, European Conference on Biomedical Optics.

[8]  B E Bouma,et al.  Scanning single-mode fiber optic catheter-endoscope for optical coherence tomography: erratum. , 1996, Optics letters.

[9]  J P Rolland,et al.  Invariant resolution dynamic focus OCM based on liquid crystal lens. , 2007, Optics express.

[10]  J. Fujimoto,et al.  Optical Coherence Tomography , 1991, LEOS '92 Conference Proceedings.

[11]  J G Fujimoto,et al.  Micromotor endoscope catheter for in vivo, ultrahigh-resolution optical coherence tomography. , 2004, Optics letters.

[12]  G. Ripandelli,et al.  Optical coherence tomography. , 1998, Seminars in ophthalmology.

[13]  Emily J. McDowell,et al.  Methods and application areas of endoscopic optical coherence tomography. , 2006, Journal of biomedical optics.

[14]  H. Rubash MASSACHUSETTS General Hospital. , 1957, Medical times.

[15]  Zhongping Chen,et al.  GRIN lens rod based probe for endoscopic spectral domain optical coherence tomography with fast dynamic focus tracking. , 2006, Optics express.

[16]  B. Golubovic,et al.  Single mode fiber-optic catheter/endoscope for optical coherence tomography , 1996, Summaries of papers presented at the Conference on Lasers and Electro-Optics.