Performance improvement of shunt active power filter with combined control technique

Recently Many researchers are focussing to improve the power quality in Power system network using active power filter. This paper Specifically presenta a newely developed method to enchance the power quality. In this work A Fuzzy Hysteresis along with Synchrous detection technique controller is developed to Control and Regulate the DC Capacitor voltage, Generation of switching signals and generation of reference currents, Fuzzy implemention in the Active filter enchance the quality simultaneously tuning with hysteresis current controller, Generation of compensating Signals compenstaes the harmonics produced by the non liner load and results a Fundamental signal. The designed filter is modeled and investigated having Non linear load using MATLAB/Simulink. Various simulation results are presented to verify the effectiveness of the proposed controller in the shunt active power filter which can be used in Three Phase and Single Phase System in Power Network.

[1]  Subhransu Sekhar Dash A Few Aspects of Power Quality Improvement Using Shunt Active Power Filter , 2011 .

[2]  Sandip Ghosh,et al.  Variable leaky least mean-square algorithm-based power system frequency estimation , 2012 .

[3]  Patrice Wira,et al.  Comparative Study of PI and Fuzzy DC Voltage Control for a DPC- PWM Rectifier , 2011 .

[4]  Pravat Kumar Ray,et al.  Signal Processing and Soft Computing Approaches to Power Signal Frequency and Harmonics Estimation , 2011 .

[5]  D. Devaraj,et al.  Fuzzy Logic – Based Approach for Adaptive Hysteresis Band and Dc Voltage Control in Shunt Active Filter , 2010 .

[6]  Gayadhar Panda,et al.  Development of Real Time Implementation of 5/5 Rule based Fuzzy Logic Controller Shunt Active Power Filter for Power Quality Improvement , 2016 .

[7]  Gayadhar Panda,et al.  Novel schemes used for estimation of power system harmonics and their elimination in a three-phase distribution system , 2013 .

[8]  Gayadhar Panda,et al.  Fuzzy logic based intelligent Shunt Hybrid filter applied to single phase system , 2013, 2013 Annual IEEE India Conference (INDICON).

[9]  Gayadhar Panda,et al.  A comparative analysis of shunt active power filter and hybrid active power filter with different control techniques applied for harmonic elimination in a single phase system , 2015, Int. J. Model. Identif. Control..

[10]  Hamza Bentria A SHUNT ACTIVE POWER FILTER CONTROLLED BY FUZZY LOGIC CONTROLLER FOR CURRENT HARMONIC COMPENSATION AND POWER FACTOR IMPROVEMENT , 2011 .

[11]  Kamal Al-Haddad,et al.  A review of active filters for power quality improvement , 1999, IEEE Trans. Ind. Electron..

[12]  Shahrokh Saadate,et al.  New control approach for four-wire active power filter based on the use of synchronous reference frame , 2005 .

[13]  P Karuppanan,et al.  Fuzzy Logic Controlled Active Power Line Conditioners for Power quality Improvements , 2010 .

[14]  Paolo Mattavelli,et al.  Comparison of current control techniques for active filter applications , 1998, IEEE Trans. Ind. Electron..