A Novel Interface for Hybrid Mock Circulations to Evaluate Ventricular Assist Devices

This paper presents a novel mock circulation for the evaluation of ventricular assist devices (VADs), which is based on a hardware-in-the-loop concept. A numerical model of the human blood circulation runs in real time and computes instantaneous pressure, volume, and flow rate values. The VAD to be tested is connected to a numerical-hydraulic interface, which allows the interaction between the VAD and the numerical model of the circulation. The numerical-hydraulic interface consists of two pressure-controlled reservoirs, which apply the computed pressure values from the model to the VAD, and a flow probe to feed the resulting VAD flow rate back to the model. Experimental results are provided to show the proper interaction between a numerical model of the circulation and a mixed-flow blood pump.

[1]  Marcel C. M. Rutten,et al.  Left Ventricular Assist Device Evaluation With a Model-Controlled Mock Circulation , 2007 .

[2]  Bart Meyns,et al.  Hemodynamic effects of partial ventricular support in chronic heart failure: results of simulation validated with in vivo data. , 2007, The Journal of thoracic and cardiovascular surgery.

[3]  Yih-Choung Yu,et al.  Feedback control design for an elastance-based mock circulatory system , 2004, Proceedings of the 2004 American Control Conference.

[4]  G Ferrari,et al.  A Hybrid Mock Circulatory System: Development and Testing of an Electro-hydraulic Impedance Simulator , 2003, The International journal of artificial organs.

[5]  P. Olver Nonlinear Systems , 2013 .

[6]  M. Chial,et al.  in simple , 2003 .

[7]  Ian Postlethwaite,et al.  Multivariable Feedback Control: Analysis and Design , 1996 .

[8]  M Arabia,et al.  Hybrid test bench for evaluation of any device related to mechanical cardiac assistance. , 2005, The International journal of artificial organs.

[9]  W. Marsden I and J , 2012 .

[10]  P. Verdonck,et al.  Computer-controlledin vitro model of the human left heart , 1992, Medical and Biological Engineering and Computing.

[11]  Ihn-Seok Ahn,et al.  Experimental Verification of the Feasibility of the Cardiovascular Impedance Simulator , 2010, IEEE Transactions on Biomedical Engineering.

[12]  J. F. Antaki,et al.  Elastance-Based Control of a Mock Circulatory System , 2001, Annals of Biomedical Engineering.

[13]  U Losert,et al.  Noninvasive monitoring of rotary blood pumps: necessity, possibilities, and limitations. , 2008, Artificial organs.

[14]  Tadahiko Shinshi,et al.  A new pulse duplicator with a passive fill ventricle for analysis of cardiac dynamics , 2010, Journal of Artificial Organs.

[15]  Mikhail Skliar,et al.  Physiologic Control of Rotary Blood Pumps: An In Vitro Study , 2004, ASAIO journal.

[16]  Stijn Vandenberghe,et al.  Pulsatile in vitro simulation of the pediatric univentricular circulation for evaluation of cardiopulmonary assist scenarios. , 2009, Artificial organs.

[17]  Lino Guzzella Analysis and Synthesis of Single-Input/Single-Output Control Systems , 2011 .

[18]  Georg Wieselthaler,et al.  Left ventricular pressure-volume loop analysis during continuous cardiac assist in acute animal trials. , 2007, Artificial organs.

[19]  Daniel Timms,et al.  A review of clinical ventricular assist devices. , 2011, Medical engineering & physics.

[20]  Marcel Jufer,et al.  In vitro experiments: Circulatory assist device interaction with a virtual cardiovascular system , 1992, 1992 14th Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[21]  D. Zimpfer,et al.  Continuous assessment of cardiac function during rotary blood pump support: a contractility index derived from pump flow. , 2010, The Journal of heart and lung transplantation : the official publication of the International Society for Heart Transplantation.

[22]  Guido Danieli,et al.  A Modified Elastance Model to Control Mock Ventricles in Real-Time: Numerical and Experimental Validation , 2008, ASAIO journal.

[23]  S Vandenberghe,et al.  A simple, economical, and effective portable paediatric mock circulatory system , 2011, Proceedings of the Institution of Mechanical Engineers. Part H, Journal of engineering in medicine.

[24]  Heinrich Schima,et al.  Dynamic Modeling and Identification of an Axial Flow Ventricular Assist Device , 2009, The International journal of artificial organs.

[25]  Ulrich Steinseifer,et al.  A compact mock circulation loop for the in vitro testing of cardiovascular devices. , 2010, Artificial organs.

[26]  James F. Antaki,et al.  A sensorless approach to control of a turbodynamic left ventricular assist system , 2001, IEEE Trans. Control. Syst. Technol..

[27]  James F. Antaki,et al.  Assessment of cardiac function during mechanical circulatory support: The quest for a suitable clinical index , 2011, 2011 Annual International Conference of the IEEE Engineering in Medicine and Biology Society.

[28]  F. Colacino,et al.  Left Ventricle Load Impedance Control by Apical VAD Can Help Heart Recovery and Patient Perfusion: A Numerical Study , 2007, ASAIO journal.

[29]  G. Ferrari,et al.  Development of a Hybrid (numerical-hydraulic) Circulatory Model: Prototype Testing and Its Response to IABP Assistance , 2005, The International journal of artificial organs.

[30]  C De Lazzari,et al.  A computer controlled mock circulatory system for mono- and biventricular assist device testing. , 1998, The International journal of artificial organs.