Pull-In Analysis of the Flat Circular CMUT Cell Featuring Sealed Cavity

Capacitive micromachined ultrasonic transducers (CMUTs) are one of the appealing MEMS devices. Most studies treat CMUTs as rigid plates vibrating in open air, ignoring the mechanical boundary conditions for simplification and resulting in cumulative errors in coupled fields. This paper presents a new analytical model for the pull-in characteristics of the flat circular CMUT cell featuring sealed cavity. Utilizing the plate theory coupled with Boyle’s law, the paper establishes a strong relation between the pressures inside the sealed cavity and the pull-in characteristics for the first time. Not only did we point out that the existence of the pressure inside the sealed cavity cannot be omitted, but we also quantified the direct effect of the pressure ratios on the pull-in phenomenon. The pull-in voltages increase while the pull-in ratios decrease with the pressure ratios of the pressure inside the sealed cavity to the ambient pressure. The proposed calculation process delivers a good approximation of the pull-in voltages and displacements, which are consistent with COMSOL simulation results. Particularly, the percentage error of our calculation process is 6.986% for the worst case. Therefore, our proposed analytical model accurately and efficiently predicts the pull-in characteristics and this paper offers new perspectives and reference value in designing and modeling the CMUTs.

[1]  Douglas A. Buchanan,et al.  Design and Characterization of a Capacitive Micromachined Transducer With a Deflectable Bottom Electrode , 2015, IEEE Electron Device Letters.

[2]  B. Khuri-Yakub,et al.  Capacitive micromachined ultrasonic transducers: next-generation arrays for acoustic imaging? , 2002, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[3]  Abdullah Atalar,et al.  Parametric nonlinear lumped element model for circular CMUTs in collapsed mode , 2014, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[4]  Kwan Kyu Park,et al.  Finite element analysis of CMUTs with pressurized cavities , 2012, 2012 IEEE International Ultrasonics Symposium.

[5]  Omer Oralkan,et al.  Capacitive micromachined ultrasonic transducers for medical imaging and therapy , 2011, Journal of micromechanics and microengineering : structures, devices, and systems.

[6]  C. A. Rich,et al.  Modeling and Characterization of CMOS-Fabricated Capacitive Micromachined Ultrasound Transducers , 2011, Journal of Microelectromechanical Systems.

[7]  B.T. Khuri-Yakub,et al.  Calculation and measurement of electromechanical coupling coefficient of capacitive micromachined ultrasonic transducers , 2003, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[8]  Edward Hæggström,et al.  Fabricating capacitive micromachined ultrasonic transducers with wafer-bonding technology , 2003 .

[9]  Rudra Pratap,et al.  Elasto-Electrostatic Analysis of Circular Microplates Used in Capacitive Micromachined Ultrasonic Transducers , 2010, IEEE Sensors Journal.

[10]  R. Pratap,et al.  Analytical Evaluation of Squeeze Film Forces in a CMUT With Sealed Air-Filled Cavity , 2011, IEEE Sensors Journal.

[11]  Shijiu Jin,et al.  Simulation characterization of CMUT with vented square membrane , 2015, International Conference on Optical Instruments and Technology.

[12]  Michael L. Kuntzman,et al.  Microfabrication and Experimental Evaluation of a Rotational Capacitive Micromachined Ultrasonic Transducer , 2015, Journal of Microelectromechanical Systems.

[13]  B. Khuri-Yakub,et al.  Fabrication of Capacitive Micromachined Ultrasonic Transducers via Local Oxidation and Direct Wafer Bonding , 2011, Journal of Microelectromechanical Systems.

[14]  D. Certon,et al.  A cMUT probe for ultrasound-guided focused ultrasound targeted therapy , 2015, IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control.

[15]  F. Teston,et al.  A finite difference model For cMUT devices , 2005, IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control.

[16]  B.T. Khuri-Yakub,et al.  Analytically calculating membrane displacement and the equivalent circuit model of a circular CMUT cell , 2008, 2008 IEEE Ultrasonics Symposium.