The Study on Hemodynamic Effect of Varied Support Models of BJUT-II VAD on Coronary Artery: A Primary CFD Study

BJUT-II VAD (Beijing University of Technology ventricular assist device II) is a novel left ventricular assist device. Because of the special connection between the pump and native heart, the hemodynamic effects of BJUT-II VAD on coronary artery are still unclear. Hence, numerical simulations have been conducted to clarify changes in hemodynamic effects of different support modes. A patient-specific left coronary arterial geometric model is reconstructed based on the computed tomography (CT) data. Three support modes, “constant speed mode,” “co-pulse mode,” and “counter pulse mode,” are used in this study. The wall shear stress (WSS), wall shear stress gradient (WSSG), cycle-averaged wall shear stress (avWSS), oscillatory shear index (OSI), and the flow pattern are calculated to evaluate the hemodynamic states of coronary artery. The computational results demonstrate that the hemodynamic states of coronary artery are directly affected by the support modes. The co-pulse modes could achieve the highest blood perfusion (constant speed: 153 ml/min vs. co-pulse: 775 ml/min vs. counter pulse: 140 ml/min) and the highest avWSS (constant speed: 18.1 Pa vs. co-pulse: 42.6 Pa vs. counter pulse: 22.6 Pa). In addition, both the WSS and WSSG at the time of peak blood velocity under the constant speed mode are lower than those under other two support modes. In contrast, the counter pulse mode generates the highest OSI value (constant speed: 0.365 vs. co-pulse: 0.379 vs. counter pulse: 0.426). BJUT-II VAD under co-pulse mode may have benefits for improving coronary perfusion and preventing the development of atherosclerosis; however, the constant speed mode may have benefit for preventing the development of plaque vulnerability.

[1]  Hans-Christian Hege,et al.  CFD analysis in an anatomically realistic coronary artery model based on non-invasive 3D imaging: comparison of magnetic resonance imaging with computed tomography , 2008, The International Journal of Cardiovascular Imaging.

[2]  S. Plein,et al.  Coronary and microvascular physiology during intra-aortic balloon counterpulsation. , 2014, JACC. Cardiovascular interventions.

[3]  Bin Gao,et al.  A Global Sliding Mode Controller Design for an Intra-Aorta Pump , 2010, ASAIO journal.

[4]  B. Gao,et al.  A Model-Free Adaptive Control to a Blood Pump Based on Heart Rate , 2011, ASAIO journal.

[5]  D. Ku,et al.  Pulsatile Flow and Atherosclerosis in the Human Carotid Bifurcation: Positive Correlation between Plaque Location and Low and Oscillating Shear Stress , 1985, Arteriosclerosis.

[6]  Habib Samady,et al.  Combination of plaque burden, wall shear stress, and plaque phenotype has incremental value for prediction of coronary atherosclerotic plaque progression and vulnerability. , 2014, Atherosclerosis.

[7]  M. Loebe,et al.  Influence of LVAD Cannula Outflow Tract Location on Hemodynamics in the Ascending Aorta: A Patient-Specific Computational Fluid Dynamics Approach , 2012, ASAIO journal.

[8]  C. Bhamidipati,et al.  Orthotopic heart transplant versus left ventricular assist device: a national comparison of cost and survival. , 2013, The Journal of thoracic and cardiovascular surgery.

[9]  Bin Gao,et al.  The hemodynamic effect of the support mode for the intra-aorta pump on the cardiovascular system. , 2013, Artificial organs.

[10]  O. Frazier,et al.  Myocardial Hemodynamics, Physiology, and Perfusion With an Axial Flow Left Ventricular Assist Device in the Calf , 2004, ASAIO journal.

[11]  Mahsa Dabagh,et al.  Hemodynamic Features in Stenosed Coronary Arteries: CFD Analysis Based on Histological Images , 2013, J. Appl. Math..

[12]  Bin Gao,et al.  Modeling and Identification of an Intra-Aorta Pump , 2010, ASAIO journal.

[13]  Michael C. McDaniel,et al.  Coronary Artery Wall Shear Stress Is Associated With Progression and Transformation of Atherosclerotic Plaque and Arterial Remodeling in Patients With Coronary Artery Disease , 2011, Circulation.

[14]  K. Kamohara,et al.  Phasic coronary blood flow pattern during a continuous flow left ventricular assist support. , 2005, European journal of cardio-thoracic surgery : official journal of the European Association for Cardio-thoracic Surgery.

[15]  S. Chien,et al.  Force-specific activation of Smad1/5 regulates vascular endothelial cell cycle progression in response to disturbed flow , 2012, Proceedings of the National Academy of Sciences.

[16]  Bin Gao,et al.  An anti-suction control for an intra-aorta pump using blood assistant index: a numerical simulation. , 2012, Artificial organs.

[17]  M. H. Friedman,et al.  Adaptive response of vascular endothelial cells to an acute increase in shear stress magnitude. , 2012, American journal of physiology. Heart and circulatory physiology.

[18]  P. Lawford,et al.  Importance of realistic LVAD profiles for assisted aortic simulations: evaluation of optimal outflow anastomosis locations , 2012, Computer methods in biomechanics and biomedical engineering.

[19]  F. N. van de Vosse,et al.  Dependence of Intramyocardial Pressure and Coronary Flow on Ventricular Loading and Contractility: A Model Study , 2006, Annals of Biomedical Engineering.

[20]  M. Yoshiyama,et al.  Relation of early improvement in coronary flow reserve to late recovery of left ventricular function after beta-blocker therapy in patients with idiopathic dilated cardiomyopathy. , 2007, American heart journal.

[21]  Zhonghua Sun,et al.  Hemodynamic impacts of various types of stenosis in the left coronary artery bifurcation: a patient-specific analysis. , 2013, Physica medica : PM : an international journal devoted to the applications of physics to medicine and biology : official journal of the Italian Association of Biomedical Physics.

[22]  Bin Gao,et al.  A Blood Assist Index Control by Intraaorta Pump: A Control Strategy for Ventricular Recovery , 2011, ASAIO journal.

[23]  Bin Gao,et al.  Hemodynamic Simulation Study of a Novel Intra-Aorta Left Ventricular Assist Device , 2012, ASAIO journal.

[24]  S. Chien,et al.  Effects of disturbed flow on vascular endothelium: pathophysiological basis and clinical perspectives. , 2011, Physiological reviews.

[25]  G. Truskey,et al.  Hemodynamic parameters and early intimal thickening in branching blood vessels. , 2001, Critical reviews in biomedical engineering.

[26]  Eun Bo Shim,et al.  Computational analysis of the effect of the type of LVAD flow on coronary perfusion and ventricular afterload , 2009, The Journal of Physiological Sciences.

[27]  Andres Ceballos,et al.  Computational fluid dynamics analysis of surgical adjustment of left ventricular assist device implantation to minimise stroke risk , 2013, Computer methods in biomechanics and biomedical engineering.

[28]  An-Shik Yang,et al.  Investigation of Pulsatile Flowfield in Healthy Thoracic Aorta Models , 2010, Annals of Biomedical Engineering.

[29]  M. Loebe,et al.  Comparison of hemodynamics in the ascending aorta between pulsatile and continuous flow left ventricular assist devices using computational fluid dynamics based on computed tomography images. , 2014, Artificial organs.

[30]  Liang Wang,et al.  Human coronary plaque wall thickness correlated positively with flow shear stress and negatively with plaque wall stress: an IVUS-based fluid-structure interaction multi-patient study , 2014, Biomedical engineering online.

[31]  D. Leong,et al.  Coronary artery wall shear stress is associated with endothelial dysfunction and expansive arterial remodelling in patients with coronary artery disease. , 2015, EuroIntervention : journal of EuroPCR in collaboration with the Working Group on Interventional Cardiology of the European Society of Cardiology.

[32]  Yu Chang,et al.  Physiological Control of Intraaorta Pump Based on Heart Rate , 2011, ASAIO journal.

[33]  M. Schaap,et al.  3D reconstruction techniques of human coronary bifurcations for shear stress computations. , 2014, Journal of biomechanics.