Magnetic Induction Tomography: A feasibility study of brain oedema detection using a finite element human head model

Neurological aggraviations of patients with craniocerebralinjury can trace back in most cases to a swelling of the brain.The survey of these patients is carried out with intracranial pressure sensors in combination with different imaging techniques. This method causes a big distress for the patients, thus new non-invasive methods are required. One promising possibility is magnetic induction tomography, a nonivasive and contactless imaging method for reconstructing the electrcal tissue properties in the region of interest. This technique is attractive for the detection of brain oedema, because the magnetic field penetrates easily through the skull and due to the increased fluid accumulation an oedema represents a more or less localized perturbation of the conductivity within a normal brain. We carried out a feasibility study with a 3D arrangement, which comprises a human brain model, an array of 16 excitation coils and 32 receiving coils. The human brain model consists of a about 35000 tetrhedral finite elements and considers the cerebrospinal fluid around the brain, the grey matter, the white matter and a spherical oedema. The inverse problem is solved by means of a single step algorithm withfour regularization methods and the results show the possibility of the detection of pathological hydration changes with good localization.

[1]  A Korjenevsky,et al.  Magnetic induction tomography: experimental realization. , 2000, Physiological measurement.

[2]  Hermann Scharfetter,et al.  Numerical solution of the general 3D eddy current problem for magnetic induction tomography (spectroscopy). , 2003, Physiological measurement.

[3]  Kimble R Dunster,et al.  Noninvasive measurement of cerebral bioimpedance for detection of cerebral edema in the neonatal piglet , 2002, Brain Research.

[4]  A. J. Peyton,et al.  A state of the art review of electromagnetic tomography. , 2003 .

[5]  David Isaacson,et al.  NOSER: An algorithm for solving the inverse conductivity problem , 1990, Int. J. Imaging Syst. Technol..

[6]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[7]  Patricia Brunner,et al.  Solution of the inverse problem of magnetic induction tomography (MIT) , 2005, Physiological measurement.

[8]  H Scharfetter,et al.  Fast calculation of the sensitivity matrix in magnetic induction tomography by tetrahedral edge finite elements and the reciprocity theorem. , 2004, Physiological measurement.

[9]  J Netz,et al.  Contactless impedance measurement by magnetic induction--a possible method for investigation of brain impedance. , 1993, Physiological measurement.

[10]  Hermann Scharfetter,et al.  Biological tissue characterization by magnetic induction spectroscopy (MIS): requirements and limitations , 2003, IEEE Transactions on Biomedical Engineering.

[11]  H. Griffiths Magnetic induction tomography , 2001 .