Aging diagnosis of large generator stator winding insulation based on digital discharge detection

The long-term accelerated aging tests in laboratory environment have been conducted on actual rotating coils subjected to combined stresses including electrical, thermal, mechanical vibration and thermal cycling factors under simulated conditions. It is to identify the meaningful diagnostic measures for the assessment of degradation and the identification of aging mechanisms. Experimental techniques for acquisition and analysis of failure data have been investigated. Partial discharge (PD) measurements have been performed using TE571 digital PD analyzer in different aging periods and a combination of statistical and basic parameters has been studied to evaluate the degradation state of stator winding insulation along with destructive measurements. It has been found that the statistical parameters such as the skewness of PD distributions appear to be correlated with the delamination in the epoxy-mica insulation system. The results provide a basis for an on-line interpretation method of stator winding insulation.

[1]  A. Contin,et al.  PD analysis of rotating AC machines , 1993 .

[2]  H. G. Sedding,et al.  The ability of diagnostic tests to estimate the remaining life of stator insulation , 1988 .

[3]  Yasuhiko Kako,et al.  Capability of Insulation Diagnosis for Mica-Resin Insulated Coils , 1980, IEEE Transactions on Electrical Insulation.

[4]  M. Kurtz,et al.  Generator Insulation Diagnostic Testing , 1979, IEEE Transactions on Power Apparatus and Systems.

[5]  M. B. Srinivas,et al.  Pulse-count distribution as a possible diagnostic tool for assessing the level of degradation of rotating machine insulation , 1990 .

[6]  H. Yoshida,et al.  Insulation Diagnosis for Rotating Machine Insulation , 1986, IEEE Transactions on Electrical Insulation.

[7]  K. Kadotani,et al.  A Proposal for Insulation Diagnosis of 3 KV Motor Stator Windings , 1983, IEEE Transactions on Electrical Insulation.

[8]  T. Okamoto,et al.  Novel Partial Discharge Measurement Computer-Aided Measuremnet Systems , 1986, IEEE Transactions on Electrical Insulation.

[9]  H. Yoshida,et al.  Test Methods of Rotating Machines , 1986, IEEE Transactions on Electrical Insulation.

[10]  Andreas Kelen,et al.  Critical Examination of the Dissipation Factor Tip-Up as a Measure of Partial Discharge Intensity , 1978, IEEE Transactions on Electrical Insulation.

[11]  E. Gulski,et al.  Computer-aided measurement of partial discharges in HV equipment , 1993 .

[12]  E. Gulski,et al.  Computer-aided recognition of discharge sources , 1992 .