The performance of 10 different methods for the estimation of sperm concentration.

OBJECTIVE To evaluate the performance of different methods of sperm counting using latex beads and sperm suspension. DESIGN A quality-control study. SETTING University-based andrology laboratory. INTERVENTION(S) None. MAIN OUTCOME MEASURE(S) Counting latex beads six times in two standard suspensions using 10 methods and counting spermatozoa with 4 methods. RESULT(S) When air-displacement pipettes were used, the disposable chambers Standard Count (Leja, Amsterdam, Holland), Cellvision (Anthos-ec, Heerhugowaard, The Netherlands), and Cell Vu (Fertility Technologies, Inc. Natick, MA) showed small variation and correct estimation of bead concentration. All the reusable chambers gave relatively large variability, with tendency to underestimate (improved Neubauer; Hawksley, Lancing, United Kingdom) or to overestimate the bead concentration. The use of plunger-displacement pipettes resulted in an overestimation of bead concentration in medium but not in seminal plasma. Counting the sperm suspension using plunger-displacement pipettes indicated that the Bürker hemocytometer overestimated concentration relative to that obtained by Cellvision and Makler Counting Chambers (Sefi Medical Instruments, Haifa, Israel) and that the improved Neubauer presented the lowest variability (7.1%). CONCLUSION(S) The improved Neubauer hemocytometer is the standard for sperm counting, though disposable chambers give reliable results as well. If beads are used to evaluate the accuracy of counting chambers, it is recommended to dilute them with seminal plasma.

[1]  F Schoonjans,et al.  Objective semen analysis: has the target been reached? , 1992, Human reproduction.

[2]  P. Matson Andrology: External quality assessment for semen analysis and sperm antibody detection: results of a pilot scheme , 1995 .

[3]  I. Cooke,et al.  Quality control during the conventional analysis of semen, an essential exercise. , 1989, Journal of andrology.

[4]  A Makler,et al.  The improved ten-micrometer chamber for rapid sperm count and motility evaluation. , 1980, Fertility and sterility.

[5]  R Eliasson,et al.  Laboratory manual for the examination of human semen and semen-cervical mucus interaction. , 1980 .

[6]  S. Mortimer,et al.  A technical note on diluting semen for the haemocytometric determination of sperm concentration. , 1989, Human reproduction.

[7]  D. Altman,et al.  STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT , 1986, The Lancet.

[8]  L. Zaneveld,et al.  Quality assurance for sperm concentration using latex beads. , 1993, Fertility and sterility.

[9]  Jane E. Johnson,et al.  Manual versus computer-automated semen analyses. Part I. Comparison of counting chambers. , 1996, Fertility and sterility.

[10]  E. Nieschlag,et al.  External quality control in the andrology laboratory: an experimental multicenter trial. , 1990, Fertility and sterility.

[11]  F. Comhaire,et al.  Human semen analysis. , 1995, Human reproduction update.

[12]  I. Cooke,et al.  Implementing comprehensive quality control in the andrology laboratory. , 1995, Human reproduction.

[13]  F Schoonjans,et al.  MedCalc: a new computer program for medical statistics. , 1995, Computer methods and programs in biomedicine.

[14]  E. Nieschlag,et al.  Internal quality control of semen analysis. , 1992, Fertility and sterility.

[15]  F. Comhaire,et al.  Validation of a single-step procedure for the objective assessment of sperm motility characteristics. , 1988, International journal of andrology.

[16]  D F Katz,et al.  A simple inexpensive method for objective assessment of human sperm movement characteristics. , 1979, Fertility and sterility.

[17]  E. Nieschlag,et al.  Bias to routine semen analysis by uncontrolled changes in laboratory environment--detection by long-term sampling of monthly means for quality control. , 1989, International journal of andrology.

[18]  D. Mortimer,et al.  Standardization and quality control of sperm concentration and sperm motility counts in semen analysis. , 1986, Human reproduction.

[19]  A. Beckett,et al.  AKUFO AND IBARAPA. , 1965, Lancet.