A Biomimetic Active Electrolocation Sensor for Detection of Atherosclerotic Lesions in Blood Vessels

Weakly electric fish sense their surroundings in complete darkness by active electrolocation. In a biomimetic approach, we designed catheter-based technical sensor systems working according to the same biological principles that could be used for medical diagnostics of arteriosclerosis. Several measurements using artificial blood vessels, computer simulations, and a physical test bed showed that it is possible to detect and analyze vulnerable plaques in blood vessels and that our method of signal production and analysis is principally suitable for medical diagnostics.

[1]  Gerhard von der Emde,et al.  Distance, shape and more: recognition of object features during active electrolocation in a weakly electric fish , 2007, Journal of Experimental Biology.

[2]  R. W. Lau,et al.  The dielectric properties of biological tissues: III. Parametric models for the dielectric spectrum of tissues. , 1996, Physics in medicine and biology.

[3]  Ruben Budelli,et al.  Electric fish measure distance in the dark , 1998, Nature.

[4]  G. Emde,et al.  Imaging of Objects through active electrolocation in Gnathonemus petersii , 2002, Journal of Physiology-Paris.

[5]  Barbara Oakley,et al.  Simulated characterization of atherosclerotic lesions in the coronary arteries by measurement of bioimpedance , 2003, IEEE Transactions on Biomedical Engineering.

[6]  C. Bell,et al.  The electric image in weakly electric fish: physical images of resistive objects in Gnathonemus petersii. , 1998, The Journal of experimental biology.

[7]  Renu Virmani,et al.  Vulnerable plaque: the pathology of unstable coronary lesions. , 2002, Journal of interventional cardiology.

[8]  R. Budelli,et al.  Peripheral electrosensory imaging by weakly electric fish , 2006, Journal of Comparative Physiology A.

[9]  B. Rasnow,et al.  The effects of simple objects on the electric field of Apteronotus , 1996, Journal of Comparative Physiology A.

[10]  Donald M. Wilson,et al.  3-Dimensional Scene Perception during Active Electrolocation in a Weakly Electric Pulse Fish , 2010, Frontiers in behavioral neuroscience.

[11]  Erling Falk,et al.  Atherosclerotic Plaque Rupture: an Overview , 2000 .

[12]  Roland Pusch,et al.  Electric imaging through active electrolocation: implication for the analysis of complex scenes , 2008, Biological Cybernetics.

[13]  G. von der Emde,et al.  Non-visual environmental imaging and object detection through active electrolocation in weakly electric fish , 2006, Journal of Comparative Physiology A.

[14]  R. W. Lau,et al.  The dielectric properties of biological tissues: II. Measurements in the frequency range 10 Hz to 20 GHz. , 1996, Physics in medicine and biology.

[15]  Gerhard von der Emde,et al.  Electric fish as natural models for technical sensor systems , 2009, Microtechnologies.

[16]  Carl D. Hopkins,et al.  Electrical Perception and Communication , 2009 .

[17]  Hector M. Garcia-Garcia,et al.  A new method to measure necrotic core and calcium content in coronary plaques using intravascular ultrasound radiofrequency-based analysis , 2010, The International Journal of Cardiovascular Imaging.

[18]  Roland Pusch,et al.  Active electrolocation in Gnathonemus petersii: Behaviour, sensory performance, and receptor systems , 2008, Journal of Physiology-Paris.

[19]  J. Bae,et al.  In-Vivo Coronary Plaque Composition in Patients with Acute Coronary Syndrome: A Virtual Histology Intravascular Ultrasound Study , 2007 .