Presented herein are the details of and results from an experimental study conducted to assess the feasibility and effectiveness of a proposed roof isolation system whose purpose is to reduce earthquake damage in buildings. The proposed isolation system entails the detachment of a building's roof from the rest of the building through the insertion of sliding bearings and the attachment of oval-shaped steel elements between the building's roof and the structure below. The objective is to form a simple resonant oscillator with a building's roof and these oval elements, with the roof providing the mass of the oscillator and the oval elements its spring and damper. An additional intention is to make the steel oval elements undergo a large number of inelastic deformation cycles and dissipate, as a result, a large portion of the energy transmitted to a building during an earthquake. The study involves the testing of a small steel frame on a shaking table alternatively with and without the proposed roof isolation system and a comparison of the story drifts and floor accelerations attained in each case. In the conducted tests, the suggested isolation technique effectively reduces the seismic response of the frame. It is concluded, thus, that the proposed roof isolation system has the potential for the development of an inexpensive and effective way to reduce earthquake damage in some buildings and merits further study.
[1]
Roberto Villaverde,et al.
Passive seismic control of cable‐stayed bridges with damped resonant appendages
,
1995
.
[2]
Andrei M. Reinhorn,et al.
Teflon Bearings in Base Isolation I: Testing
,
1990
.
[3]
Roberto Villaverde,et al.
Damped resonant appendages to increase inherent damping in buildings
,
1993
.
[4]
Manuel Aguirre,et al.
STRUCTURAL SEISMIC DAMPER
,
1992
.
[5]
Gilberto Mosqueda,et al.
Aseismic roof isolation system: analytic and shake table studies
,
1999
.
[6]
Manuel Aguirre.
Device for Control of Building Settlement and for Seismic Protection
,
1991
.
[7]
M. Aguirre,et al.
Antiseismic structure: damper-equipped elastic frame
,
2001
.
[8]
R Medeot,et al.
SPECIAL DISSIPATING DEVICES FOR REDUCING SEISMIC RESPONSE OF STRUCTURES
,
1990
.
[9]
Roberto Villaverde,et al.
Aseismic Roof Isolation System: Feasibility Study with 13-Story Building
,
2002
.
[10]
Roberto Villaverde,et al.
Roof Isolation System to Reduce the Seismic Response of Buildings: A Preliminary Assessment
,
1998
.
[11]
James M. Kelly,et al.
Hysteretic dampers for earthquake‐resistant structures
,
1974
.
[12]
Roberto Villaverde,et al.
Reduction seismic response with heavily-damped vibration absorbers
,
1985
.