Design of a series elastic- and Bowden cable-based actuation system for use as torque-actuator in exoskeleton-type training

Common actuators have important drawbacks for use in an exoskeleton type of rehabilitation (training) robot. Either the actuators are heavy, complex or poor torque sources. A new actuation system is proposed and tested that combines a lightweight joint and a simple structure with adequate torque source quality. It consists of a servomotor, a flexible Bowden cable transmission, and a force feedback loop based on a series elastic element. Measurements show that performance is sufficient for use in a gait rehabilitation robot.

[1]  David W. Robinson,et al.  Design and analysis of series elasticity in closed-loop actuator force control , 2000 .

[2]  Blake Hannaford,et al.  Control law design for haptic interfaces to virtual reality , 2002, IEEE Trans. Control. Syst. Technol..

[3]  G.A. Pratt,et al.  Series elastic actuator development for a biomimetic walking robot , 1999, 1999 IEEE/ASME International Conference on Advanced Intelligent Mechatronics (Cat. No.99TH8399).

[4]  S. Hesse,et al.  Upper and lower extremity robotic devices for rehabilitation and for studying motor control , 2003, Current opinion in neurology.

[5]  N. Hogan,et al.  Increasing productivity and quality of care: robot-aided neuro-rehabilitation. , 2000, Journal of rehabilitation research and development.

[6]  H. van der Kooij,et al.  LOPES: selective control of gait functions during the gait rehabilitation of CVA patients , 2005, 9th International Conference on Rehabilitation Robotics, 2005. ICORR 2005..

[7]  Steven C Cramer,et al.  Robotics, motor learning, and neurologic recovery. , 2004, Annual review of biomedical engineering.