STUDY OBJECTIVE
To determine the accuracy of end-tidal carbon dioxide levels as a measure of arterial carbon dioxide levels in nonintubated patients presenting to an emergency department for care.
DESIGN
A prospective, cross-sectional analysis.
SETTING
University hospital ED.
TYPE OF PARTICIPANT
Nonintubated adult patients presenting to the ED for care of a variety of problems.
INTERVENTIONS
Patients who had arterial blood gas samples taken as part of their ED evaluation were asked to breathe normally through an endotracheal tube adapter or a modified nasal cannula connected to a side port sampling capnometer while a sample for arterial blood gas was drawn from the radial artery.
MEASUREMENTS
End-tidal carbon dioxide levels (mm Hg) were recorded at the time of arterial blood gas sampling. The difference between end-tidal carbon dioxide and PaCO2 was tested with the paired t-test at a significance level of .05. The correlation of end-tidal carbon dioxide to PaCO2 was tested in all patients and in subgroups using simple linear regression.
RESULTS
Seventy-six patients were enrolled. In all patients, end-tidal carbon dioxide was 3.5 mm Hg lower than PaCO2 and correlated well with PaCO2 (r2 = .772). In patients with hypocapnia, there was no significant difference between end-tidal carbon dioxide and PaCO2 (P = .17), and the correlation of end-tidal carbon dioxide to PaCO2 was stronger (r2 = .838). In patients with a respiratory or metabolic acidosis, the difference between end-tidal carbon dioxide and PaCO2 was 6 mm Hg (P = .005), but end-tidal carbon dioxide correlated well to PaCO2 (r2 = .899).
CONCLUSION
Measurements of end-tidal carbon dioxide concentrations correlate well with PaCO2 values in nonintubated patients presenting with a variety of conditions to EDs. End-tidal carbon dioxide measurements may be sufficient measures of PaCO2 in selected patients and obviate the need for repeat arterial blood gas determination. Further study is warranted.
[1]
A. Sandler,et al.
End-tidal CO2 monitoring in spontaneously breathing adults
,
1989,
Canadian journal of anaesthesia = Journal canadien d'anesthesie.
[2]
C. Barton,et al.
Prediction of outcome of cardiopulmonary resuscitation from end‐tidal carbon dioxide concentration
,
1990,
Critical care medicine.
[3]
A. Sanders.
Capnometry in emergency medicine.
,
1989,
Annals of emergency medicine.
[4]
D B Raemer,et al.
Variation in PCO2 between Arterial Blood and Peak Expired Gas during Anesthesia
,
1983,
Anesthesia and analgesia.
[5]
F. Scamman,et al.
Ventilatory frequency influences accuracy of end-tidal CO2 measurements. Analysis of seven capnometers.
,
1988,
Anesthesia and analgesia.
[6]
R Fletcher,et al.
Invasive and Noninvasive Measurement of the Respiratory Deadspace in Anesthetized Children with Cardiac Disease
,
1988,
Anesthesia and analgesia.
[7]
C W Otto,et al.
End-Tidal Carbon Dioxide Monitoring During Cardiopulmonary Resuscitation: A Prognostic Indicator for Survival
,
1989
.