Robust STATCOM control for the stabilisation of fixed-speed wind turbines during low voltages

This paper presents a robust voltage control scheme for fixed-speed wind generators using a static synchronous compensator (STATCOM) controller. To enable a linear and robust control framework with structured uncertainty, the overall system is represented by a linear part plus a nonlinear part that covers an operating range of interest required to ensure stability during severe low voltages. The proposed methodology is flexible and readily applicable to larger wind farms of different configurations. The performance of the control strategy is demonstrated on a two area test system. Large disturbance simulations demonstrate that the proposed controller enhances voltage stability as well as transient stability of induction generators during low voltage ride through (LVRT) transients and thus enhances the LVRT capability.

[1]  Liangzhong Yao,et al.  A STATCOM with supercapacitors for enhanced power system stability , 2008 .

[2]  Hannele Holttinen,et al.  The effect of large scale wind power on a thermal system operation , 2004 .

[3]  Luis M. Fernández,et al.  Equivalent models of wind farms by using aggregated wind turbines and equivalent winds , 2009 .

[4]  A. Brito-Melo,et al.  IEA-OES International Energy Agency Implementing Agreement on Ocean Energy Systems annual report 2008 , 2009 .

[5]  Ian R. Petersen,et al.  A connection between H∞ control and the absolute stabilizability of discrete-time uncertain linear systems , 1995, Autom..

[6]  Shinji Arinaga,et al.  Power variation control of a wind generator by using feed forward control , 1999 .

[7]  Tomonobu Senjyu,et al.  Output Power Leveling of Wind Turbine Generator by Pitch Angle Control Using H ∞ Control , 2007 .

[8]  Poul Ejnar Sørensen,et al.  Design of a wind turbine pitch angle controller for power system stabilisation , 2007 .

[9]  I. Petersen,et al.  Robust Control Design Using H-? Methods , 2012 .

[10]  Hemanshu R. Pota,et al.  Voltage mode stabilisation in power systems with dynamic loads , 2010 .

[11]  G. L. Johnson,et al.  Wind energy systems , 1985 .

[12]  T. Funabashi,et al.  Output power leveling of wind turbine generator by pitch angle control using adaptive control method , 2004, 2004 International Conference on Power System Technology, 2004. PowerCon 2004..

[13]  M. J. Hossain,et al.  Excitation control for large disturbances in power systems with dynamic loads , 2009, 2009 IEEE Power & Energy Society General Meeting.

[14]  P. Ledesma,et al.  Doubly fed induction generator model for transient stability analysis , 2005, IEEE Transactions on Energy Conversion.

[15]  R. Itoh,et al.  Series connected PWM GTO current/source convertor with symmetrical phase angle control , 1990 .

[16]  M. Hacil,et al.  Advanced Backstepping controller for induction generator using multi-scalar machine model for wind power purposes , 2010 .

[17]  Ian R. Petersen,et al.  Robust Control Design Using H-infinity Methods , 2000 .

[18]  Ian R. Petersen,et al.  Nonlinear versus linear control in the absolute stabilizability of uncertain systems with structured uncertainty , 1995, IEEE Trans. Autom. Control..

[19]  Francisco Jurado,et al.  An adaptive control scheme for biomass-based diesel–wind system , 2003 .

[20]  J. Sun,et al.  Voltage flicker mitigation using PWM-based distribution STATCOM , 2002, IEEE Power Engineering Society Summer Meeting,.

[21]  Sarath B. Tennakoon,et al.  Evaluation of the suitability of a fixed speed wind turbine for large scale wind farms considering the new UK grid code , 2008 .

[22]  N. Mohan,et al.  A novel robust low voltage and fault ride through for wind turbine application operating in weak grids , 2005, 31st Annual Conference of IEEE Industrial Electronics Society, 2005. IECON 2005..

[23]  P. Kundur,et al.  Power system stability and control , 1994 .

[24]  Thomas Ackermann,et al.  Wind Power in Power Systems , 2005 .

[25]  Wilsun Xu,et al.  Control design and dynamic performance analysis of a wind turbine-induction generator unit , 2000 .

[26]  Niels Kjølstad Poulsen,et al.  A Dynamic Stability Limit of Grid Connected Induction Generators , 2000 .

[27]  Hemanshu R Pota,et al.  Simultaneous STATCOM and Pitch Angle Control for Improved LVRT Capability of Fixed-Speed Wind Turbines , 2010, IEEE Transactions on Sustainable Energy.

[28]  B.H. Chowdhury,et al.  Power flow and stability models for induction generators used in wind turbines , 2004, IEEE Power Engineering Society General Meeting, 2004..

[29]  P. Olver Nonlinear Systems , 2013 .