Magnetoencephalography with an atomic magnetometer

The authors demonstrate detection and mapping of brain magnetic fields evoked by auditory stimulation with a noncryogenic magnetometer based on spin precession of potassium atoms in spin-exchange-relaxation-free regime. Optical readout using a photodiode array allows flexibility in detector placement while using common elements for most components of the multichannel system. Absence of a cryogenic dewar eliminates magnetic Johnson noise from radiation shields and allows the use of a compact magnetic shield with a high shielding factor. The magnetometer sensitivity is currently equal to 3.5fT∕Hz1∕2 at 10Hz, similar to superconducting quantum interference device magnetoencephalography systems.

[1]  A. Papanicolaou,et al.  A review of clinical applications of magnetoencephalography. , 2005, International review of neurobiology.

[2]  Michael V. Romalis,et al.  Unshielded three-axis vector operation of a spin-exchange-relaxation-free atomic magnetometer , 2004 .

[3]  D. Linden The P300: Where in the Brain Is It Produced and What Does It Tell Us? , 2005, The Neuroscientist : a review journal bringing neurobiology, neurology and psychiatry.

[4]  D. Cohen Magnetoencephalography: Detection of the Brain's Electrical Activity with a Superconducting Magnetometer , 1972, Science.

[5]  R Wynands,et al.  Dynamical mapping of the human cardiomagnetic field with a room-temperature, laser-optical sensor. , 2003, Optics express.

[6]  G. Romani,et al.  Magnetoencephalography - a noninvasive brain imaging method with 1 ms time resolution , 2001 .

[7]  [Recording of human magnetic fields]. , 1978, Doklady Akademii nauk SSSR.

[8]  I. Sasada,et al.  Experimental correction of the axial shielding equation , 2002 .

[9]  Aniruddh D. Patel,et al.  Temporal patterns of human cortical activity reflect tone sequence structure , 2000, Nature.

[10]  Changes in parameters of auditory evoked magnetic fields with click train patterns , 1999 .

[11]  R. Ilmoniemi,et al.  Magnetoencephalography-theory, instrumentation, and applications to noninvasive studies of the working human brain , 1993 .

[12]  T. W. Kornack,et al.  A subfemtotesla multichannel atomic magnetometer , 2003, Nature.

[13]  W. Happer,et al.  Spin-Exchange Shift and Narrowing of Magnetic Resonance Lines in Optically Pumped Alkali Vapors , 1973 .

[14]  A. Bloom Principles of operation of the rubidium vapor magnetometer , 1962 .