Performance characteristics of anthropomorphic prosthetic hands

In this paper we set forth a review of performance characteristics for both common commercial prosthetics as well as anthropomorphic research devices. Based on these specifications as well as surveyed results from prosthetic users, ranges of hand attributes are evaluated and discussed. End user information is used to describe the performance requirements for prosthetic hands for clinical use.

[1]  A. Kargov,et al.  The FLUIDHAND III: A Multifunctional Prosthetic Hand , 2009 .

[2]  Gianluca Palli,et al.  Development of UB Hand 3: Early Results , 2005, Proceedings of the 2005 IEEE International Conference on Robotics and Automation.

[3]  Christian Cipriani,et al.  Objectives, criteria and methods for the design of the SmartHand transradial prosthesis , 2009, Robotica.

[4]  C. Snijders,et al.  Quantifying thumb rotation during circumduction utilizing a video technique , 2003, Journal of orthopaedic research : official publication of the Orthopaedic Research Society.

[5]  Hong Liu,et al.  Multisensory five-finger dexterous hand: The DLR/HIT Hand II , 2008, 2008 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[6]  Elaine Biddiss,et al.  Consumer design priorities for upper limb prosthetics , 2007, Disability and rehabilitation. Assistive technology.

[7]  S. Naumann,et al.  Multiple finger, passive adaptive grasp prosthetic hand , 2001 .

[8]  M. Goldfarb,et al.  Design of a Multifunctional Anthropomorphic Prosthetic Hand With Extrinsic Actuation , 2009, IEEE/ASME Transactions on Mechatronics.

[9]  Aaron M. Dollar,et al.  An investigation of grasp type and frequency in daily household and machine shop tasks , 2011, 2011 IEEE International Conference on Robotics and Automation.

[10]  José Luis Pons Rovira,et al.  The MANUS-HAND Dextrous Robotics Upper Limb Prosthesis: Mechanical and Manipulation Aspects , 2004, Auton. Robots.

[11]  J. W. Bill Limehouse A PRELIMINARY STUDY OF 40+ UPPER EXTREMITY PATIENTS USING THE ANIMATED CONTROL SYSTEM , 2005 .

[12]  K. Bergman,et al.  Functional benefit of an adaptive myoelectric prosthetic hand compared to a conventional myoelectric hand , 1992, Prosthetics and orthotics international.

[13]  Takashi Maeno,et al.  Underactuated five-finger prosthetic hand inspired by grasping force distribution of humans , 2008, 2008 IEEE/RSJ International Conference on Intelligent Robots and Systems.

[14]  C. Pylatiuk,et al.  Results of an Internet survey of myoelectric prosthetic hand users , 2007, Prosthetics and orthotics international.

[15]  Paolo Dario,et al.  Design and development of an underactuated prosthetic hand , 2002, Proceedings 2002 IEEE International Conference on Robotics and Automation (Cat. No.02CH37292).

[16]  John T. McConville,et al.  INVESTIGATION OF INERTIAL PROPERTIES OF THE HUMAN BODY , 1975 .

[17]  R Vinet,et al.  Design methodology for a multifunctional hand prosthesis. , 1995, Journal of rehabilitation research and development.

[18]  A. Kargov,et al.  A comparison of the grip force distribution in natural hands and in prosthetic hands , 2004, Disability and rehabilitation.

[19]  C M Light,et al.  Development of a lightweight and adaptable multiple-axis hand prosthesis. , 2000, Medical engineering & physics.

[20]  F. Lotti,et al.  How Far Is the Human Hand ? A Review on Anthropomorphic Robotic End-effectors , 2003 .

[21]  Richard F. ff. Weir,et al.  CHAPTER 32 DESIGN OF ARTIFICIAL ARMS AND HANDS FOR PROSTHETIC APPLICATIONS , 2005 .