Neutral-point shifting and voltage unbalance due to single-phase DG units in low voltage distribution networks

When distributed generation (DG) units are connected to a low voltage (LV) single-phase distribution network the voltage profile will change. The connection of single-phase DG units to three-phase distribution networks will not only alter the voltage profile in the connected phase, but also the two other phase voltages will be influenced due to neutral-point shifting and voltage unbalance. The purpose of this paper is to examine the influence of single-phase DG units on the phase voltages, in different circumstances. This will be investigated by performing several simulations. In order to make these detailed simulations, an unbalanced multiphase harmonic power flow method, considering the neutral wire, will be proposed. The presented model uses the iterative forward/backward method. Furthermore, the network is solved by using symmetrical components and the prevalent convergence problems will be tackled in this paper.

[1]  A. Testa,et al.  An improvement of the iterative harmonic analysis method , 2007 .

[2]  A. Testa,et al.  Some considerations on the iterative harmonic analysis convergence , 1992 .

[3]  L. Sainz,et al.  Study of neutral conductor current in three-phase networks with single-phase converters , 2006, IEEE Transactions on Power Delivery.

[4]  A. Testa,et al.  Modeling waveform distortion produced by DC locomotive conversion system. Part 1: Locomotive model , 2004, 2004 11th International Conference on Harmonics and Quality of Power (IEEE Cat. No.04EX951).

[5]  Seong-Jeub Jeon,et al.  Non-sinusoidal power theory in a power system having transmission lines with frequency-dependent resistances , 2007 .

[6]  Eleonora Riva Sanseverino,et al.  A modified backward/forward method for fast solving radial distribution networks , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.

[7]  D. Shirmohammadi,et al.  A compensation-based power flow method for weakly meshed distribution and transmission networks , 1988 .

[8]  D. Shirmohammadi,et al.  A three-phase power flow method for real-time distribution system analysis , 1995 .

[9]  R. M. Ciric,et al.  Power flow in four-wire distribution networks-general approach , 2003 .

[10]  Alan R. Wood,et al.  A review of iterative harmonic analysis for AC-DC power systems , 1998 .

[11]  Jfg Sjef Cobben Power quality : implications at the point of connection , 2007 .

[12]  K. Tomsovic,et al.  Adaptive Power Flow Method for Distribution Systems with Dispersed Generation , 2002, IEEE Power Engineering Review.

[13]  J. Teng,et al.  Three-phase unbalanced distribution power flow solutions with minimum data preparation , 1999 .

[14]  W. M. Grady,et al.  Statistical summation of the harmonic currents produced by a large number of single phase variable speed air conditioners: a study of three specific designs , 1998, 8th International Conference on Harmonics and Quality of Power. Proceedings (Cat. No.98EX227).

[15]  T. Inoue,et al.  Three-phase cogenerator and transformer models for distribution system analysis , 1991 .

[16]  Jen-Hao Teng,et al.  Backward/Forward Sweep-Based Harmonic Analysis Method for Distribution Systems , 2007, IEEE Transactions on Power Delivery.

[17]  F. de Leon,et al.  Unbalanced Multiphase Load-Flow Using a Positive-Sequence Load-Flow Program , 2008, IEEE Transactions on Power Systems.

[18]  A.F. Zobaa The optimal passive filters to minimize voltage harmonic distortion at a load bus , 2005, IEEE Transactions on Power Delivery.

[19]  Johan Gyselinck,et al.  Nonlinear transformer model in the frequency domain and with symmetrical components , 2008 .

[20]  F. D'hulster,et al.  Thermal analysis of the influence of nonlinear, unbalanced and asymmetric loads on current conducting capacity of LV-cables , 2003, 2003 IEEE Bologna Power Tech Conference Proceedings,.