Retrofitting Effect on the Dynamic Properties of Model-Arch Dam with and without Reservoir Water Using Ambient-Vibration Test Methods

AbstractContinuous health monitoring and regular condition assessment is of vital importance for engineering structures in general and especially for arch dams. These structures can be exposed to many different loads such as earthquake, blast, wind, ice, and water pressure, which may cause deterioration and loss of structural integrity. Such development may have severe economic consequence and, more importantly, may present a serious risk to public safety. Therefore, the structural behavior of arch dams must be monitored at regular intervals during their service life, although the overall failure rate of these dams is around 1%. Experimental measurements by ambient vibration test methods are among the most commonly preferred inspection techniques for the evaluation of structural performance and safety. The aim of this research is to examine the retrofitting effect on the dynamic properties of a damaged arch dam model, with and without reservoir water, after retrofitting with high-strength structural repai...

[1]  Ziyad H. Duron Experimental and Finite Element Studies of a Large Arch Dam , 1987 .

[2]  Jean Proulx,et al.  Continuous ambient‐vibration monitoring of the arch dam of Mauvoisin , 2002 .

[3]  Chuhan H. Zhang,et al.  Earthquake damage analysis of arch dams considering dam–water–foundation interaction , 2013 .

[4]  C. Loh,et al.  IDENTIFICATION OF FEI-TSUI ARCH DAM FROM BOTH AMBIENT AND SEISMIC RESPONSE DATA , 1996 .

[5]  Carlos E. Ventura,et al.  Why Output Only Modal Analysis is a Desirable Tool for a Wide Range of Practical Applications , 2003 .

[6]  Temel Türker,et al.  Vibration based damage identification of concrete arch dams by finite element model updating , 2014 .

[7]  Rui Faria,et al.  Numerical simulation of collapse scenarios in reduced scale tests of arch dams , 2006 .

[8]  Alemdar Bayraktar,et al.  Investigation of water length effects on the modal behavior of a prototype arch dam using operational and analytical modal analyses , 2011 .

[9]  Fabrizio Barpi,et al.  Fuzzy parameters analysis of time‐dependent fracture of concrete dam models , 2002 .

[10]  Alemdar Bayraktar,et al.  Finite element model updating effects on nonlinear seismic response of arch dam-reservoir-foundation systems , 2011 .

[11]  A. A. Dumanoglu,et al.  Reservoir water level effects on nonlinear dynamic response of arch dams , 2008 .

[12]  Mohammad Alembagheri,et al.  Damage assessment of a concrete arch dam through nonlinear incremental dynamic analysis , 2013 .

[13]  Alemdar Bayraktar,et al.  Dynamic Characteristics of an Arch Dam Model before and after Strengthening with Consideration of Reservoir Water , 2016 .

[14]  Anca-Maria Toader,et al.  Damage identification in a concrete dam by fitting measured modal parameters , 2012 .

[15]  Chuhan Zhang,et al.  Seismic damage-cracking analysis of arch dams using different earthquake input mechanisms , 2009 .

[16]  Melvin J. Dubnick Army Corps of Engineers , 1998 .

[17]  P. Paultre,et al.  An experimental investigation of water level effects on the dynamic behaviour of a large arch dam , 2001 .

[18]  Alemdar Bayraktar,et al.  Experimental evaluation of crack effects on the dynamic characteristics of a prototype arch dam using ambient vibration tests , 2012 .