Filter-Based Active Damping of Voltage Source Converters With $LCL$ Filter

Pulsewidth modulation (PWM) voltage source converters are becoming a popular interface to the power grid for many applications. Hence, issues related to the reduction of PWM harmonics injection in the power grid are becoming more relevant. The use of high-order filters like LCL filters is a standard solution to provide the proper attenuation of PWM carrier and sideband voltage harmonics. However, those grid filters introduce potentially unstable dynamics that should be properly damped either passively or actively. The second solution suffers from control and system complexity (a high number of sensors and a high-order controller), even if it is more attractive due to the absence of losses in the damping resistors and due to its flexibility. An interesting and straightforward active damping solution consists in plugging in, in cascade to the main controller, a filter that should damp the unstable dynamics. No more sensors are needed, but there are open issues such as preserving the bandwidth, robustness, and limited complexity. This paper provides a systematic approach to the design of filter-based active damping methods. The tuning procedures, performance, robustness, and limitations of the different solutions are discussed with theoretical analysis, selected simulation, and experimental results.

[1]  Marco Liserre,et al.  Grid Converters for Photovoltaic and Wind Power Systems , 2011 .

[2]  Friedrich Wilhelm Fuchs,et al.  Active Damping for Three-Phase PWM Rectifiers With High-Order Line-Side Filters , 2009, IEEE Transactions on Industrial Electronics.

[3]  F. Fuchs,et al.  PWM rectifier with LCL-filter using different current control structures , 2007, 2007 European Conference on Power Electronics and Applications.

[4]  A. Draou,et al.  A new state feedback based transient control of PWM AC to DC voltage type converters , 1995 .

[5]  H. Pinheiro,et al.  Design and Implementation of a Robust Current Controller for VSI Connected to the Grid Through an LCL Filter , 2009, IEEE Transactions on Power Electronics.

[6]  J.W. Kolar,et al.  A modified direct power control strategy allowing the connection of three-phase inverter to the grid through LCL filters , 2005, Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005..

[7]  Manfred Morari,et al.  Explicit Model-Predictive Control of a PWM Inverter With an LCL Filter , 2009, IEEE Transactions on Industrial Electronics.

[8]  J. Doval-Gandoy,et al.  On the discrete-time implementation of resonant controllers for active power filters , 2009, 2009 35th Annual Conference of IEEE Industrial Electronics.

[9]  M. Liserre,et al.  Stability of photovoltaic and wind turbine grid-connected inverters for a large set of grid impedance values , 2006, IEEE Transactions on Power Electronics.

[10]  D. Cartes,et al.  Study On Grid Connected Inverter Used in High Power Wind Generation System , 2006, Conference Record of the 2006 IEEE Industry Applications Conference Forty-First IAS Annual Meeting.

[11]  Mariusz Malinowski,et al.  A Simple Voltage Sensorless Active Damping Scheme for Three-Phase PWM Converters With an $LCL$ Filter , 2008, IEEE Transactions on Industrial Electronics.

[12]  Steffan Hansen,et al.  Investigation of Active Damping Approaches for PI-Based Current Control of Grid-Connected Pulse Width Modulation Converters With LCL Filters , 2010, IEEE Transactions on Industry Applications.

[13]  M. Liserre,et al.  Genetic algorithm-based design of the active damping for an LCL-filter three-phase active rectifier , 2003, IEEE Transactions on Power Electronics.

[14]  M. Liserre,et al.  Stability improvements of an LCL-filter based three-phase active rectifier , 2002, 2002 IEEE 33rd Annual IEEE Power Electronics Specialists Conference. Proceedings (Cat. No.02CH37289).

[15]  F.A. Magueed,et al.  Control of VSC connected to the grid through LCL-filter to achieve balanced currents , 2005, Fourtieth IAS Annual Meeting. Conference Record of the 2005 Industry Applications Conference, 2005..

[16]  Massimo Bongiorno,et al.  Frequency-domain passivity-based current controller design , 2008 .

[17]  M. Liserre,et al.  Design and control of an LCL-filter based three-phase active rectifier , 2001, Conference Record of the 2001 IEEE Industry Applications Conference. 36th IAS Annual Meeting (Cat. No.01CH37248).

[18]  J. Van den Keybus,et al.  Model-based generation of low distortion currents in grid-coupled PWM-inverters using an LCL output filter , 2004, 2004 IEEE 35th Annual Power Electronics Specialists Conference (IEEE Cat. No.04CH37551).

[19]  M. Liserre,et al.  Grid Impedance Estimation via Excitation of $LCL$ -Filter Resonance , 2007, IEEE Transactions on Industry Applications.

[20]  Mariusz Malinowski,et al.  Evaluation of three-level rectifiers for low-voltage utility applications , 2005, IEEE Transactions on Industrial Electronics.

[21]  Joachim Rudolph,et al.  On Some Nonlinear Current Controllers for Three-Phase Boost Rectifiers , 2009, IEEE Transactions on Industrial Electronics.

[22]  Stephen J. Finney,et al.  A Modified Stationary Reference Frame-Based Predictive Current Control With Zero Steady-State Error for LCL Coupled Inverter-Based Distributed Generation Systems , 2011, IEEE Transactions on Industrial Electronics.

[23]  R.W. De Doncker,et al.  Active damping of LCL resonance with minimum sensor effort by means of a digital infinite impulse response filter , 2007, 2007 European Conference on Power Electronics and Applications.

[24]  Kim-Fung Man,et al.  Design and optimization of IIR filter structure using hierarchical genetic algorithms , 1998, IEEE Trans. Ind. Electron..

[25]  FREDE BLAABJERG,et al.  Sensitivity Analysis Of An LCL-Filter-Based Three-Phase Active Rectifier Via A "Virtual Circuit" Approach , 2004, J. Circuits Syst. Comput..

[26]  M. Liserre,et al.  Characterization of differential-mode filter for grid-side converters , 2009, 2009 35th Annual Conference of IEEE Industrial Electronics.

[27]  V. Blasko,et al.  A novel control to actively damp resonance in input LC filter of a three phase voltage source converter , 1996, Proceedings of Applied Power Electronics Conference. APEC '96.

[28]  L. Norum,et al.  Active damping of resonance oscillations in LCL-filters based on virtual flux and virtual resistor , 2007, 2007 European Conference on Power Electronics and Applications.

[29]  Juan C. Vasquez,et al.  Adaptive Droop Control Applied to Voltage-Source Inverters Operating in Grid-Connected and Islanded Modes , 2009, IEEE Transactions on Industrial Electronics.

[30]  Yuling Li,et al.  A double-loop current control strategy for Shunt Active Power Filter with LCL filter , 2009, 2009 IEEE International Symposium on Industrial Electronics.

[31]  Poh Chiang Loh,et al.  Analysis of multiloop control strategies for LC/CL/LCL-filtered voltage-source and current-source inverters , 2005, IEEE Transactions on Industry Applications.

[32]  Po-Tai Cheng,et al.  Design of a State-Feedback Controller for Series Voltage-Sag Compensators , 2009, IEEE Transactions on Industry Applications.

[33]  Friedrich Wilhelm Fuchs,et al.  PI state space current control of grid- connected PWM converters with LCL filters , 2009, 2009 IEEE Energy Conversion Congress and Exposition.

[34]  William S. Levine,et al.  The Control Handbook , 2005 .

[35]  Yan Zhou,et al.  Parameter Design of a Two-Current-Loop Controller Used in a Grid-Connected Inverter System With LCL Filter , 2009, IEEE Transactions on Industrial Electronics.

[36]  Massimo Bongiorno,et al.  Voltage Dip Mitigation Using Shunt-Connected Voltage Source Converter , 2007 .

[37]  Vinod John,et al.  Filter Optimization for Grid Interactive Voltage Source Inverters , 2010, IEEE Transactions on Industrial Electronics.

[38]  Isabelle Queinnec,et al.  Robust LQR Control for PWM Converters: An LMI Approach , 2009, IEEE Transactions on Industrial Electronics.

[39]  Frede Blaabjerg,et al.  Overview of Control and Grid Synchronization for Distributed Power Generation Systems , 2006, IEEE Transactions on Industrial Electronics.

[40]  S. Mazumder,et al.  Reaching Criterion of a Three-Phase Voltage-Source Inverter Operating With Passive and Nonlinear Loads and Its Impact on Global Stability , 2008, IEEE Transactions on Industrial Electronics.

[41]  S. Cobreces,et al.  Control of grid-connected voltage source converters with LCL filter using a Linear Quadratic servocontroller with state estimator , 2008, 2008 IEEE Power Electronics Specialists Conference.

[42]  P.W. Lehn,et al.  Digital Current Control of a Voltage Source Converter With Active Damping of LCL Resonance , 2006, IEEE Transactions on Power Electronics.

[43]  Lennart Harnefors Implementation of Resonant Controllers and Filters in Fixed-Point Arithmetic , 2009, IEEE Transactions on Industrial Electronics.

[44]  Yun Wei Li,et al.  Control and Resonance Damping of Voltage-Source and Current-Source Converters With $LC$ Filters , 2009, IEEE Transactions on Industrial Electronics.

[45]  Ali Emadi,et al.  Active Damping in DC/DC Power Electronic Converters: A Novel Method to Overcome the Problems of Constant Power Loads , 2009, IEEE Transactions on Industrial Electronics.

[46]  Donald Grahame Holmes,et al.  Grid current regulation of a three-phase voltage source inverter with an LCL input filter , 2003 .

[47]  M. Liserre,et al.  Future Energy Systems: Integrating Renewable Energy Sources into the Smart Power Grid Through Industrial Electronics , 2010, IEEE Industrial Electronics Magazine.

[48]  Christian Wessels,et al.  Limitations of Voltage-Oriented PI Current Control of Grid-Connected PWM Rectifiers With $LCL$ Filters , 2009, IEEE Transactions on Industrial Electronics.

[49]  Zhihong Ye,et al.  Output filter design for a grid-interconnected three-phase inverter , 2003, IEEE 34th Annual Conference on Power Electronics Specialist, 2003. PESC '03..

[50]  Dehong Xu,et al.  An Improved Control Strategy for Grid-Connected Voltage Source Inverters With an LCL Filter , 2006, IEEE Transactions on Power Electronics.

[51]  J.W. Kolar,et al.  A Modified Direct Power Control Strategy Allowing the Connection of Three-Phase Inverters to the Grid Through $LCL$ Filters , 2005, IEEE Transactions on Industry Applications.