Thermometry in Therapeutic Hyperthermia

The delivery of local and regional therapeutic hyperthermia in clinical practice proves to be a difficult challenge. The objective is to elevate the temperature of malignant tissue to a uniform level in excess of some minimum therapeutic temperature (e.g., 42.0 °C) for a period on the order of 30–60 min. At the same time, normal tissue temperatures should be maintained at subtherapeutic levels. This objective is seldom achieved. The difficulty is associated not so much with excessive heating of normal tissue (normal tissue toxicity is thus far reportedly low) as with achieving a minimum, uniform therapeutic temperature in the target tissue volume. It is known that thermal cytotoxicity is very temperature dependent [1]. In addition, thermal tolerance, the ability of cells to become resistant to elevated temperature, is another phenomenon that is highly dependent on temperature and exposure time and may be therapeutically relevant [1,2].

[1]  J. McDougall,et al.  Perturbations due to the use of catheters with non-perturbing thermometry probes. , 1988, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[2]  Kenneth R. Holmes,et al.  MICROVASCULAR CONTRIBUTIONS IN TISSUE HEAT TRANSFER , 1980, Annals of the New York Academy of Sciences.

[3]  M. Dewhirst,et al.  Estimation of therapeutic gain in clinical trials involving hyperthermia and radiotherapy. , 1986, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[4]  G. Nussbaum Physical aspects of hyperthermia , 1982 .

[5]  K. Paulsen,et al.  Theoretical temperature distributions produced by an annular phased array-type system in CT-based patient models. , 1984, Radiation research.

[6]  J. Hand,et al.  Physical Techniques in Clinical Hyperthermia , 1986 .

[7]  T. Cetas,et al.  Will thermometric tomography become practical for hyperthermia treatment monitoring? , 1984, Cancer research.

[8]  B. Mangum,et al.  Triple point of succinonitrile and its use in the calibration of thermistor thermometers , 1983 .

[9]  P. Barth,et al.  Thin linear thermometer arrays for use in localized cancer hyperthermia , 1982, IEEE Transactions on Electron Devices.

[10]  M. Dewhirst,et al.  Automated temperature scanning for hyperthermia treatment monitoring. , 1987, International Journal of Radiation Oncology, Biology, Physics.

[11]  G. Lovisolo,et al.  Tumour response to heat and radiation: prognostic variables in the treatment of neck node metastases from head and neck cancer. , 1985, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[12]  R. Roemer Treatment Planning and Evaluation , 1987 .

[13]  K. A. Wickersheim,et al.  A New Fiberoptic Thermometry System For Use In Medical Hyperthermia , 1987, Other Conferences.

[14]  I A Brezovich,et al.  Error sources affecting thermocouple thermometry in RF electromagnetic fields. , 1982, The Journal of microwave power.

[15]  S. B. Field,et al.  An assessment of local hyperthermia in clinical practice. , 1986, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[16]  T P Ryan,et al.  Computer-controlled temperature multiplexer for thermal dosimetry studies. , 1984, Journal of biomedical engineering.

[17]  S. Weinbaum,et al.  A new simplified bioheat equation for the effect of blood flow on local average tissue temperature. , 1985, Journal of biomechanical engineering.

[18]  P. Dunscombe,et al.  Heat production in microwave-irradiated thermocouples. , 1986, Medical physics.

[19]  T. Samulski,et al.  Photoluminescent thermometer probes: temperature measurements in microwave fields. , 1980, Science.

[20]  James F. Greenleaf,et al.  Non-Intrusive Measurement of Microwave and Ultrasound-Induced Hyperthermia by Acoustic Temperature Tomography , 1977 .

[21]  W. Fry,et al.  Determination of Absolute Sound Levels and Acoustic Absorption Coefficients by Thermocouple Probes—Theory , 1954 .

[22]  Robert C. Eberhart,et al.  “Thermal Characteristics of Tumors: Applications in Detection and Treatment,” Annals of the New York Academy of Sciences , 1981 .

[23]  T L Phillips,et al.  RTOG quality assurance guidelines for clinical trials using hyperthermia. , 1990, International journal of radiation oncology, biology, physics.

[24]  D. Christensen,et al.  Multiple Sensor Optical Thermometry System for Application in Clinical Hyperthermia , 1984, IEEE Transactions on Biomedical Engineering.

[25]  R. R. Sholes,et al.  Fluorescent decay thermometer with biological applications , 1980 .

[26]  R S Cox,et al.  Stanford University institutional report. Phase I evaluation of equipment for hyperthermia treatment of cancer. , 1988, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[27]  B. Paliwal,et al.  Hyperthermia thermometry evaluation: criteria and guidelines. , 1988, International journal of radiation oncology, biology, physics.

[28]  Dennis L. Parker,et al.  Applications of NMR Imaging in Hyperthermia: An Evaluation of the Potential for Localized Tissue Heating and Noninvasive Temperature Monitoring , 1984, IEEE Transactions on Biomedical Engineering.

[29]  S D Prionas,et al.  Noninvasive thermometry using multiple-frequency-band radiometry: a feasibility study. , 1985, Bioelectromagnetics.

[30]  D. Christensen,et al.  Influence of Temperature Probe Sheathing Materials During Ultrasonic Heating , 1986, IEEE Transactions on Biomedical Engineering.

[31]  J. Overgaard,et al.  Some problems related to the clinical use of thermal isoeffect doses. , 1987, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[32]  R H Britt,et al.  Temperature measurements in high thermal gradients: II. Analysis of conduction effects. , 1985, International journal of radiation oncology, biology, physics.

[33]  T. Samulski,et al.  Correlations of thermal washout rate, steady state temperatures, and tissue type in deep seated recurrent or metastatic tumors. , 1987, International journal of radiation oncology, biology, physics.

[34]  T. Samulski,et al.  Anatomical site-specific modalities for hyperthermia. , 1984, Cancer research.

[35]  S M Bentzen,et al.  Isotherm mapping in hyperthermia using subtraction X-ray computed tomography. , 1984, Radiotherapy and oncology : journal of the European Society for Therapeutic Radiology and Oncology.

[36]  Carl H. Durney,et al.  A Nonperturbing Temperature Sensor for Measurements in Electromagnetic Fields , 1974 .

[37]  R. Britt,et al.  Temperature measurements in high thermal gradients: I. The effects of conduction. , 1985, International journal of radiation oncology, biology, physics.

[38]  C. Song Effect of local hyperthermia on blood flow and microenvironment: a review. , 1984, Cancer research.

[39]  H. F. Bowman,et al.  Heat transfer and thermal dosimetry. , 1981, The Journal of microwave power.

[40]  F. Gibbs "Thermal mapping" in experimental cancer treatment with hyperthermia: description and use of a semi-automatic system. , 1983, International journal of radiation oncology, biology, physics.

[41]  Edwin M. Candler THERMOCOUPLE REFERENCE TABLES , 1967 .

[42]  S. Mizushina,et al.  A Three-Band Microwave Radiometer for Noninvasive Temperature Measurement , 1984 .

[43]  A. Guy,et al.  Nonionizing electromagnetic wave effects in biological materials and systems , 1972 .

[44]  P Dunscombe,et al.  Perturbation of the temperature distribution in microwave irradiated tissue due to the presence of metallic thermometers. , 1987, Medical physics.

[45]  M Knudsen,et al.  Two-point control of temperature profile in tissue. , 1986, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[46]  F. Gibbs,et al.  Regional hyperthermia in the treatment of clinically advanced, deep seated malignancy: results of a pilot study employing an annular array applicator. , 1984, International journal of radiation oncology, biology, physics.

[47]  D L Parker,et al.  Temperature distribution measurements in two-dimensional NMR imaging. , 1983, Medical physics.

[48]  J R Oleson,et al.  Analysis of prognostic variables in hyperthermia treatment of 161 patients. , 1984, International journal of radiation oncology, biology, physics.

[49]  C. Pichot,et al.  Microwave thermography--characteristics of waveguide applicators and signatures of thermal structures. , 1982, The Journal of microwave power.

[50]  Ervin B. Podgorsak,et al.  Noninvasive thermometry with a clinical x‐ray CT scanner , 1982 .

[51]  J. van der Zee,et al.  The use of implanted closed-tip catheters for the introduction of thermometry probes during local hyperthermia treatment series. , 1987, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[52]  Thermal Models/Temperature Distributions , 1987 .

[53]  R. Dickinson,et al.  The practical use of thermocouples for temperature measurement in clinical hyperthermia. , 1986, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[54]  J W Hand,et al.  Quality assurance guidelines for ESHO protocols. , 1989, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[55]  F. Sterzer,et al.  A Self-Balancing Microwave Radiometer for Non-Invasively Measuring the Temperature of Subcutaneous Tissues During Localized Hyperthermia Treatments of Cancer , 1982, 1982 IEEE MTT-S International Microwave Symposium Digest.

[56]  T. Samulski,et al.  Direct temperature measurement. , 1984, Cancer research.

[57]  T. Samulski,et al.  Photoluminescent thermometry based on europium-activated calcium sulphide. , 1982, Physics in medicine and biology.

[58]  J. Sylvester,et al.  Clinical application of thermal isoeffect dose. , 1987, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[59]  Robert B. Roemer,et al.  Inference of Complete Tissue Temperature Fields from a Few Measured Temperatures: An Unconstrained Optimization Method , 1984, IEEE Transactions on Biomedical Engineering.

[60]  H. Sostman Melting point of gallium as a temperature calibration standard , 1977 .

[61]  C R Hill,et al.  Ultrasonic attenuation and propagation speed in mammalian tissues as a function of temperature. , 1979, Ultrasound in medicine & biology.

[62]  J R Mallard,et al.  Errors in temperature measurement by thermocouple probes during ultrasound induced hyperthermia. , 1983, The British journal of radiology.

[63]  Edward S. Sternick,et al.  Non-invasive temperature mapping by computerized tomography , 1981 .

[64]  M. Dewhirst,et al.  Hyperthermia quality assurance guidelines. , 1989, International journal of radiation oncology, biology, physics.

[65]  J. A. Wise,et al.  Thermometer calibration: A model for state calibration laboratories , 1986 .

[66]  T. Sugiura,et al.  A Three-Band Microwave Radiometer System for Noninvasive Measurement of the Temperature at Various Depths , 1986, 1986 IEEE MTT-S International Microwave Symposium Digest.

[67]  Robert B. Roemer,et al.  A Survey of Computer Simulations of Hyperthermia Treatments , 1984, IEEE Transactions on Biomedical Engineering.

[68]  R. Dickinson Thermal conduction errors of manganin-constantan thermocouple arrays , 1985 .

[69]  J. McDougall,et al.  Changes in heating patterns due to perturbations by thermometer probes at 915 and 434 MHz. , 1988, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[70]  J. van der Zee,et al.  Retrospective analysis of the response of tumours in patients treated with a combination of radiotherapy and hyperthermia. , 1986, International journal of hyperthermia : the official journal of European Society for Hyperthermic Oncology, North American Hyperthermia Group.

[71]  T. Cetas,et al.  Thermometry considerations in localized hyperthermia. , 1978, Medical physics.

[72]  G. Hahn Hyperthermia and Cancer , 1982, Springer US.

[73]  R. Olsen,et al.  Coaxial Nonmetallic Thermocouple with Electronic Ice Point for Dosimetric Use in Electromagnetic Environments , 1982 .

[74]  R. R. Bowman A Probe for Measuring Temperature in Radio-Frequency-Heated Material (Short Papers) , 1976 .

[75]  John S. Steinhart,et al.  Calibration curves for thermistors , 1968 .

[76]  R. Dickinson,et al.  Linear thermocouple arrays for in vivo observation of ultrasonic hyperthermia fields. , 1984, The British journal of radiology.

[77]  F. Waterman The response of thermometer probes inserted into catheters. , 1985, Medical physics.