A numerical simulation of steady flow fields in a bypass tube.

Steady flow in a complete by-pass tube was simulated numerically. The study was to consider a complete flow field, which included both the by-pass and the host tubes. The changes of the hemodynamics were investigated with three parameters: the inlet flow Reynolds number (Re), anastomotic angle (alpha) and the position of the occlusion in the host tube. The baseline flow field was set up with Re=200, alpha=45 degrees and the centered position of occlusion. The parametric study was then conducted on combination of Re=100, 200, 400, alpha=35 degrees, 45 degrees, 60 degrees, 75 degrees, 90 degrees and three occlusion positions: left, center and right. It was found that in the baseline case, large slow/recirculation flows could be seen in the host tube both upstream and downstream of the occlusion. The separation points were on the opposite walls to the junctions. Recirculation zones were also found near the toe and in the proximal outer wall of the by-pass tube. Their sizes were about one diameter of the tube or smaller. In some cases, pairing vortices could be seen in the host tube upstream of the occlusion. The shear rate distribution associated with the flow fields was presented. The flow pattern obtained was agreeable to those observed experimentally by other investigators. The difference of the flow fields between a complete bypass and simple anastomosis was discussed. The present numerical code provides a preliminary simulation/design tool for bypass graft flows.

[1]  D. L. Fry Certain Histological and Chemical Responses of the Vascular Interface to Acutely Induced Mechanical Stress in the Aorta of the Dog , 1969, Circulation research.

[2]  C. R. Ethier,et al.  Steady and pulsatile flow fields in an end-to-side arterial anastomosis model. , 1990, Journal of vascular surgery.

[3]  J D Thomas,et al.  The effect of angle and flow rate upon hemodynamics in distal vascular graft anastomoses: a numerical model study. , 1991, Journal of biomechanical engineering.

[4]  C. Kleinstreuer,et al.  Hemodynamic simulations and computer-aided designs of graft-artery junctions. , 1997, Journal of biomechanical engineering.

[5]  J. Chiu,et al.  Covariant velocity-based calculation procedure with nonstaggered grids for computation of pulsatile flows , 1992 .

[6]  R. Schroter,et al.  Atheroma and arterial wall shear - Observation, correlation and proposal of a shear dependent mass transfer mechanism for atherogenesis , 1971, Proceedings of the Royal Society of London. Series B. Biological Sciences.

[7]  T V How,et al.  Effects of geometry and flow division on flow structures in models of the distal end-to-side anastomosis. , 1996, Journal of Biomechanics.

[8]  Clark K. Colton,et al.  Microcinematographic studies of flow patterns in the excised rabbit aorta and its major branches. , 1997, Biorheology.

[9]  S Glagov,et al.  Anastomotic intimal hyperplasia: mechanical injury or flow induced. , 1992, Journal of vascular surgery.

[10]  C Kleinstreuer,et al.  Flow input waveform effects on the temporal and spatial wall shear stress gradients in a femoral graft-artery connector. , 1996, Journal of biomechanical engineering.

[11]  H. Schima,et al.  Numerical study of wall mechanics and fluid dynamics in end-to-side anastomoses and correlation to intimal hyperplasia. , 1996, Journal of biomechanics.

[12]  Y. Cho,et al.  Experimental investigation of branch flow ratio, angle, and Reynolds number effects on the pressure and flow fields in arterial branch models. , 1985, Journal of biomechanical engineering.

[13]  Y. L. Chiu,et al.  Platelet adhesion onto the wall of a flow chamber with an obstacle. , 1997, Biorheology.

[14]  D. Liepsch,et al.  Measurement and calculations of laminar flow in a ninety degree bifurcation. , 1982, Journal of biomechanics.

[15]  O Smedby,et al.  Predilection of atherosclerosis for the inner curvature in the femoral artery. A digitized angiography study. , 1995, Arteriosclerosis, thrombosis, and vascular biology.

[16]  L. Talbot,et al.  Flow in Curved Pipes , 1983 .

[17]  F. S. Henry,et al.  Numerical investigation of steady flow in proximal and distal end-to-side anastomoses. , 1996, Journal of biomechanical engineering.

[18]  Denz Lee,et al.  Computation of physiological bifurcation flows using a patched grid , 1992 .

[19]  C. R. Ethier,et al.  Flow waveform effects on end-to-side anastomotic flow patterns. , 1998, Journal of biomechanics.

[20]  P. Hughes,et al.  Visualization of vortex shedding at the proximal side-to-end artery-graft anastomosis. , 1996, Biorheology.

[21]  H Nygaard,et al.  The anastomosis angle does change the flow fields at vascular end-to-side anastomoses in vivo. , 1995, Journal of vascular surgery.

[22]  D Lee,et al.  Numerical simulation of flow fields in a tube with two branches. , 2000, Journal of biomechanics.

[23]  E. M. Pedersen,et al.  Influence of abdominal aortic curvature and resting versus exercise conditions on velocity fields in the normal abdominal aortic bifurcation. , 1994, Journal of biomechanical engineering.