Hydrodynamic focusing for microfluidic impedance cytometry: a system integration study

We present the first in-depth system integration study of in-plane hydrodynamic focusing in a microfluidic impedance cytometry lab-on-a-chip. The method relies on constricting the detection volume with non-conductive sheath flows and characterizing particles or cells based on changes in impedance. This approach represents an avenue of overcoming current limitations in sensitivity with translating cytometers to the point of care for rapid, low-cost blood analysis. While examples of integrated devices are present in the literature, no systematic study of the interplay between hydrodynamics and electrodynamics has been carried out as of yet. We develop analytical and numerical models to describe the impedimetric response of the sensor as a function of cellular characteristics, physical flow properties, and device geometry. We fabricate a working prototype lab-on-a-chip for experimental validation using latex particles. We find that ionic diffusion can be a critical limiting factor even at high Péclet number. Moreover, we explore geometric variations, revealing that the ionic diffusion-related distance between the center of the hydrodynamic focusing junction and the impedance measurement electrodes plays a dominant role. With our device, we demonstrate over fivefold enhancement in impedance signals and population separation with in-plane hydrodynamic focusing. It is only through such in-depth system studies, in both models and experiments, that optimal utilization of microsystem capabilities becomes possible.

[1]  Jin-Woo Choi,et al.  Point-of-care testing (POCT) diagnostic systems using microfluidic lab-on-a-chip technologies , 2015 .

[2]  H Morgan,et al.  Analytical electric field and sensitivity analysis for two microfluidic impedance cytometer designs. , 2007, IET nanobiotechnology.

[3]  Muhammad Asraf Mansor,et al.  Single Cell Electrical Characterization Techniques , 2015, International journal of molecular sciences.

[4]  H. Morgan,et al.  Single-colloidal particle impedance spectroscopy: complete equivalent circuit analysis of polyelectrolyte microcapsules. , 2010, Langmuir : the ACS journal of surfaces and colloids.

[5]  Junbo Wang,et al.  Microfluidic Impedance Flow Cytometry Enabling High-Throughput Single-Cell Electrical Property Characterization , 2015, International journal of molecular sciences.

[6]  H. Berg Random Walks in Biology , 2018 .

[7]  Robert Langer,et al.  Design and Testing of an Impedance-Based Sensor for Monitoring Drug Delivery , 2005 .

[8]  Gwo-Bin Lee,et al.  The hydrodynamic focusing effect inside rectangular microchannels , 2006 .

[9]  Martin Arundell,et al.  High-speed particle detection in a micro-Coulter counter with two-dimensional adjustable aperture. , 2008, Biosensors & bioelectronics.

[10]  W. Bentley,et al.  Multi-depth valved microfluidics for biofilm segmentation , 2015 .

[11]  O. Siggaard‐Andersen,et al.  Physicochemical quantities and units in clinical chemistry with special emphasis on activities and activity coefficients (Recommendations 1983) , 1984 .

[12]  Hywel Morgan,et al.  Dielectric spectroscopy of single cells: time domain analysis using Maxwell's mixture equation , 2007 .

[13]  Mehmet Toner,et al.  A robust electrical microcytometer with 3-dimensional hydrofocusing. , 2009, Lab on a chip.

[14]  Lisa C Shriver-Lake,et al.  Effect of diffusion on impedance measurements in a hydrodynamic flow focusing sensor. , 2010, Lab on a chip.

[15]  Bruce H. Davis,et al.  Laboratory Hematology Practice , 2012 .

[16]  Howard M. Shapiro,et al.  Practical Flow Cytometry , 1985 .

[17]  Hywel Morgan,et al.  Single-cell microfluidic impedance cytometry: a review , 2010 .

[18]  C. P. Bean,et al.  Counting and Sizing of Submicron Particles by the Resistive Pulse Technique , 1970 .

[19]  S. Gawad,et al.  Single cell dielectric spectroscopy , 2007 .

[20]  David R. Lide,et al.  CRC HANDBOOK of THERMOPHYSICAL and THERMOCHEMICAL DATA , 1994 .

[21]  H. Morgan,et al.  Microfluidic lysis of human blood for leukocyte analysis using single cell impedance cytometry. , 2012, Analytical chemistry.

[22]  J. Samitier,et al.  Low cost micro-Coulter counter with hydrodynamic focusing , 2007 .

[23]  Koji Asami,et al.  Dielectric Approach to Suspensions of Ellipsoidal Particles Covered with a Shell in Particular Reference to Biological Cells , 1980 .

[24]  Jeffrey S Erickson,et al.  The good, the bad, and the tiny: a review of microflow cytometry , 2008, Analytical and bioanalytical chemistry.

[25]  H. Shapiro Practical Flow Cytometry: Shapiro/Flow Cytometry 4e , 2005 .

[26]  F. Ligler,et al.  Parameters affecting the shape of a hydrodynamically focused stream , 2011 .

[27]  Hywel Morgan,et al.  ANALYTICAL AND NUMERICAL MODELING METHODS FOR IMPEDANCE ANALYSIS OF SINGLE CELLS ON-CHIP , 2008 .

[28]  Rashid Bashir,et al.  BioMEMS: state-of-the-art in detection, opportunities and prospects. , 2004, Advanced drug delivery reviews.

[29]  Hywel Morgan,et al.  Micro-impedance cytometry for detection and analysis of micron-sized particles and bacteria. , 2011, Lab on a chip.

[30]  S. Gawad,et al.  Impedance spectroscopy flow cytometry: On‐chip label‐free cell differentiation , 2005, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[31]  E. Pitts,et al.  Concentration dependence of electrolyte conductance. Part 2.—Comparison of experimental data with the Fuoss-Onsager and Pitts treatments , 1970 .

[32]  Yu Sun,et al.  On-chip sample preparation for complete blood count from raw blood. , 2015, Lab on a chip.

[33]  Urban Seger,et al.  Dielectric spectroscopy in a micromachined flow cytometer: theoretical and practical considerations. , 2004, Lab on a chip.

[34]  Mansoor Nasir,et al.  Hydrodynamic focusing—a versatile tool , 2011, Analytical and Bioanalytical Chemistry.

[35]  Uwe Schnakenberg,et al.  Simultaneous optical and impedance analysis of single cells: A comparison of two microfluidic sensors with sheath flow focusing , 2015 .

[36]  Horst-Günter Rubahn,et al.  Influence of geometry on hydrodynamic focusing and long-range fluid behavior in PDMS microfluidic chips , 2012 .

[37]  Pasqualina M. Sarro,et al.  Integrated Coulter counter based on 2-dimensional liquid aperture control , 2004 .

[38]  William G. Finn,et al.  Laboratory Hematology Practice , 2012 .

[39]  Junjie Zhu,et al.  Particle focusing in microfluidic devices , 2010 .

[40]  G. Kovacs,et al.  Microfluidic impedance cytometer for platelet analysis. , 2013, Lab on a chip.

[41]  Arkadiusz Pierzchalski,et al.  Microfluidic impedance‐based flow cytometry , 2010, Cytometry. Part A : the journal of the International Society for Analytical Cytology.

[42]  S. Gawad,et al.  Micromachined impedance spectroscopy flow cytometer for cell analysis and particle sizing. , 2001, Lab on a chip.

[43]  Christian H. Reccius,et al.  Leukocyte analysis and differentiation using high speed microfluidic single cell impedance cytometry. , 2009, Lab on a chip.

[44]  Peter H. Dykstra,et al.  A microfluidic-based electrochemical biochip for label-free DNA hybridization analysis. , 2014, Journal of visualized experiments : JoVE.

[45]  H. Morgan,et al.  Integrated systems for rapid point of care (PoC) blood cell analysis. , 2011, Lab on a chip.