Fluorescence Lifetime Imaging and Intravascular Ultrasound: Co-Registration Study Using Ex Vivo Human Coronaries

Fluorescence lifetime imaging (FLIM) has demonstrated potential for robust assessment of atherosclerotic plaques biochemical composition and for complementing conventional intravascular ultrasound (IVUS), which provides information on plaque morphology. The success of such a bi-modal imaging modality depends on accurate segmentation of the IVUS images and proper angular registration between these two modalities. This paper reports a novel IVUS segmentation methodology addressing this issue. The image preprocessing consisted of denoising, using the Wiener filter, followed by image smoothing, implemented through the application of the alternating sequential filter on the edge separability metric images. Extraction of the lumen/intima and media/adventitia boundaries was achieved by tracing the gray-scale peaks over the A-lines of the IVUS preprocessed images. Cubic spline interpolation, in both cross-sectional and longitudinal directions, ensured boundary smoothness and continuity. The detection of the guide-wire artifact in both modalities is used for angular registration. Intraluminal studies were conducted in 13 ex vivo segments of human coronaries. The IVUS segmentation accuracy was assessed against independent manual tracings, providing 91.82% sensitivity and 97.55% specificity. The proposed methodology makes the bi-modal FLIM and IVUS approach feasible for comprehensive intravascular diagnosis by providing co-registered biochemical and morphological information of atherosclerotic plaques.

[1]  Jianwu Dang,et al.  An anisotropic diffusion filter for reducing speckle noise of ultrasound images based on separability , 2012, Proceedings of The 2012 Asia Pacific Signal and Information Processing Association Annual Summit and Conference.

[2]  M. Fishbein,et al.  A fluorescence lifetime imaging classification method to investigate the collagen to lipid ratio in fibrous caps of atherosclerotic plaque , 2012, Lasers in surgery and medicine.

[3]  Laura Marcu,et al.  Multispectral fluorescence lifetime imaging system for intravascular diagnostics with ultrasound guidance: in vivo validation in swine arteries , 2014, Journal of biophotonics.

[4]  D. Steinberg,et al.  Multimodality direct coronary imaging with combined near‐infrared spectroscopy and intravascular ultrasound: Initial US experience , 2013, Catheterization and cardiovascular interventions : official journal of the Society for Cardiac Angiography & Interventions.

[5]  C. Weber,et al.  Atherosclerosis: current pathogenesis and therapeutic options , 2011, Nature Medicine.

[6]  Noriaki Suetake,et al.  Fuzzy inference-based plaque boundary extraction using image separability for intravascular ultrasound image of coronary artery , 2009 .

[7]  Mark D. Huffman,et al.  Heart disease and stroke statistics--2013 update: a report from the American Heart Association. , 2013, Circulation.

[8]  Laura Marcu,et al.  Multimodal characterization of compositional, structural and functional features of human atherosclerotic plaques , 2011, Biomedical optics express.

[9]  Akiko Maehara,et al.  Consensus standards for acquisition, measurement, and reporting of intravascular optical coherence tomography studies: a report from the International Working Group for Intravascular Optical Coherence Tomography Standardization and Validation. , 2012, Journal of the American College of Cardiology.

[10]  Noriaki Suetake,et al.  Automated boundary extraction and visualization system for coronary plaque in IVUS image by using fuzzy inference-based method , 2011, 2011 IEEE International Conference on Fuzzy Systems (FUZZ-IEEE 2011).

[11]  Laura Marcu,et al.  Bi-modal imaging of atherosclerotic plaques: Automated method for co-registration between fluorescence lifetime imaging and intravascular ultrasound data , 2014, Photonics West - Biomedical Optics.

[12]  V. Ntziachristos,et al.  Indocyanine Green Enables Near-Infrared Fluorescence Imaging of Lipid-Rich, Inflamed Atherosclerotic Plaques , 2011, Science Translational Medicine.

[13]  Brett E Bouma,et al.  Intravascular optical imaging technology for investigating the coronary artery. , 2011, JACC. Cardiovascular imaging.

[14]  Laura Marcu,et al.  Fluorescence lifetime in cardiovascular diagnostics. , 2010, Journal of biomedical optics.

[15]  David Day-Uei Li,et al.  Comment on ‘A novel method for fast and robust estimation of fluorescence decay dynamics using constrained least-square deconvolution with Laguerre expansion’ , 2017, Physics in medicine and biology.

[16]  E. Gerardo Mendizabal-Ruiz,et al.  Computerized Medical Imaging and Graphics , 2022 .

[17]  E. Tuzcu,et al.  Coronary Plaque Classification With Intravascular Ultrasound Radiofrequency Data Analysis , 2002, Circulation.

[18]  Rafael C. González,et al.  Digital image processing, 3rd Edition , 2008 .

[19]  Ioannis Kompatsiaris,et al.  Image analysis techniques for automated IVUS contour detection. , 2008, Ultrasound in medicine & biology.

[20]  P. Serruys,et al.  IVUS-based imaging modalities for tissue characterization: similarities and differences , 2011, The International Journal of Cardiovascular Imaging.

[21]  Vasilis Ntziachristos,et al.  Improving quantification of intravascular fluorescence imaging using structural information. , 2012, Physics in medicine and biology.

[22]  Christine Connolly,et al.  Handbook of Image and Video Processing 2nd Edition (Hardback) , 2006 .

[23]  Masataka Nakano,et al.  Acute Coronary Events , 2012, Circulation.

[24]  J. Lakowicz Principles of fluorescence spectroscopy , 1983 .

[25]  Petros Maragos,et al.  Segmentation of soil section images using connected operators , 2001, Proceedings 2001 International Conference on Image Processing (Cat. No.01CH37205).

[26]  Laura Marcu,et al.  Design, construction, and validation of a rotary multifunctional intravascular diagnostic catheter combining multispectral fluorescence lifetime imaging and intravascular ultrasound , 2012, Journal of biomedical optics.

[27]  Milan Sonka,et al.  Graph-Based IVUS Segmentation With Efficient Computer-Aided Refinement , 2013, IEEE Transactions on Medical Imaging.

[28]  Nassir Navab,et al.  A State-of-the-Art Review on Segmentation Algorithms in Intravascular Ultrasound (IVUS) Images , 2012, IEEE Transactions on Information Technology in Biomedicine.

[29]  Kazuhiro Fukui,et al.  Edge Extraction Method Based on Separability of Image Features , 1995, MVA.

[30]  Laura Marcu,et al.  A novel method for fast and robust estimation of fluorescence decay dynamics using constrained least-squares deconvolution with Laguerre expansion , 2017, Physics in medicine and biology.

[31]  K. Moore,et al.  Macrophages in the Pathogenesis of Atherosclerosis , 2011, Cell.

[32]  Elisa E. Konofagou,et al.  Automatic detection of blood versus non-blood regions on intravascular ultrasound (IVUS) images using wavelet packet signatures , 2008, SPIE Medical Imaging.

[33]  Jiayong Yan,et al.  A random walk-based method for segmentation of intravascular ultrasound images , 2014, Medical Imaging.

[34]  Jerry D. Gibson,et al.  Handbook of Image and Video Processing , 2000 .

[35]  John A Hossack,et al.  Intravascular near-infrared fluorescence catheter with ultrasound guidance and blood attenuation correction , 2013, Journal of biomedical optics.

[36]  Paulino Vacas-Jacques,et al.  Optical coherence tomography--near infrared spectroscopy system and catheter for intravascular imaging. , 2013, Optics express.

[37]  F. Jaffer,et al.  Intravascular near-infrared fluorescence molecular imaging of atherosclerosis. , 2013, American journal of nuclear medicine and molecular imaging.

[38]  Vasilis Ntziachristos,et al.  Two-dimensional intravascular near-infrared fluorescence molecular imaging of inflammation in atherosclerosis and stent-induced vascular injury. , 2011, Journal of the American College of Cardiology.

[39]  Frits Mastik,et al.  In vivo 3D distribution of lipid-core plaque in human coronary artery as assessed by fusion of near infrared spectroscopy-intravascular ultrasound and multislice computed tomography scan. , 2010, Circulation. Cardiovascular imaging.