Flow Boiling Heat Transfer on Micro Pin Fins Entrenched in a Microchannel

Flow boiling of 1-methoxyheptafluoropropane (HFE 7000) in 222 μm hydraulic diameter channels containing a single row of 24 inline 100 μm pin fins was studied for mass fluxes from 350 kg/m2 s to 827 kg/m2 s and wall heat fluxes from 10 W/cm2 to 110 W/cm2. Flow visualization revealed the existence of isolated bubbles, bubbles interacting, multiple flow, and annular flow. The observed flow patterns were mapped as a function of the boiling number and the normalized axial distance. The local heat transfer coefficient during subcooled boiling was measured and found to be considerably higher than the corresponding single-phase flow. Furthermore, a thermal performance evaluation comparison with a plain microchannel revealed that the presence of pin fins considerably enhanced the heat transfer coefficient.

[1]  B. Mikic,et al.  A New Correlation of Pool-Boiling Data Including the Effect of Heating Surface Characteristics , 1969 .

[2]  Keith Cornwell,et al.  The influence of bubbly flow on boiling from a tube in a bundle , 1990 .

[3]  Santosh V. Krishnamurthy,et al.  Flow Boiling on Micropin Fins Entrenched Inside a Microchannel-Flow Patterns and Bubble Departure Diameter and Bubble Frequency , 2010 .

[4]  F. Pfefferkorn,et al.  Experimental Study of Pressure Drop and Heat Transfer in a Single-Phase Micropin-Fin Heat Sink , 2007 .

[5]  L. Witte,et al.  An experimental investigation of the effects of subcooling and velocity on boiling of freon-113 , 1996 .

[6]  M. Mohammed Shah,et al.  Improved General Correlation for Subcooled Boiling Heat Transfer During Flow Across Tubes and Tube Bundles , 2005 .

[7]  J. C. Chen Correlation for Boiling Heat Transfer to Saturated Fluids in Convective Flow , 1966 .

[8]  Björn Palm,et al.  Subcooled Flow Boiling of R134a in a Vertical Channel of Small Diameter , 2007 .

[9]  D. Kenning,et al.  Subcooled flow boiling at high heat flux , 1985 .

[10]  Y. Lie,et al.  Saturated flow boiling heat transfer and associated bubble characteristics of R-134a in a narrow annular duct , 2005 .

[11]  W. Qu,et al.  Liquid Single-Phase Flow in an Array of Micro-Pin-Fins—Part I: Heat Transfer Characteristics , 2008 .

[12]  Thomas J. Cognata,et al.  High-Speed Visualization of Two-Phase Flow in a Micro-Scale Pin-Fin Heat Exchanger , 2007 .

[13]  S. Rouhani,et al.  CALCULATION OF VOID VOLUME FRACTION IN THE SUBCOOLED AND QUALITY BOILING REGIONS , 1970 .

[14]  W. Rohsenow,et al.  The Determination of Forced-Convection Surface-Boiling Heat Transfer , 1964 .

[15]  S. S. Kutateladze BOILING HEAT TRANSFER , 1961 .

[16]  R. Prasher,et al.  Nusselt Number and Friction Factor of Staggered Arrays of Low Aspect Ratio Micropin-Fins Under Cross Flow for Water as Fluid , 2007 .

[17]  Yoav Peles,et al.  Flow boiling of water in a circular staggered micro-pin fin heat sink , 2008 .

[18]  Santosh V. Krishnamurthy,et al.  Gas-liquid two-phase flow across a bank of micropillars , 2007 .

[19]  A. Koşar,et al.  Boiling heat transfer in a hydrofoil-based micro pin fin heat sink , 2007 .

[20]  Vijay K. Dhir,et al.  Wall Heat Flux Partitioning During Subcooled Flow Boiling: Part 1—Model Development , 2005 .

[21]  D. Murray,et al.  Surface heat transfer due to sliding bubble motion , 2009 .

[22]  G. R. Hall,et al.  Correlation of forced convection boiling heat transfer data , 1982 .

[23]  A. Koşar,et al.  Convective flow of refrigerant (R-123) across a bank of micro pin fins , 2006 .

[24]  Vijay K. Dhir,et al.  Heat Transfer and Wall Heat Flux Partitioning During Subcooled Flow Nucleate Boiling—A Review , 2006 .

[25]  Frank E. Pfefferkorn,et al.  Pressure Drop and Heat Transfer in a Single-Phase Micro-Pin-Fin Heat Sink , 2006 .

[26]  Vijay K. Dhir,et al.  Wall Heat Flux Partitioning During Subcooled Flow Boiling: Part II—Model Validation , 2005 .

[27]  J. R. T. Lahey A MECHANISTIC SUBCOOLED BOILING MODEL , 1978 .

[28]  Fan-Gang Tseng,et al.  Bubble dynamics in microchannels. Part I: single microchannel , 2004 .

[29]  Akhilesh Gupta,et al.  Enhancement of boiling heat transfer in a 5 × 3 tube bundle , 2005 .

[30]  Satish G. Kandlikar,et al.  Heat Transfer Characteristics in Partial Boiling, Fully Developed Boiling, and Significant Void Flow Regions of Subcooled Flow Boiling , 1997, Fluids Engineering.

[31]  Lidong Huang,et al.  Highly Subcooled Boiling in Crossflow , 2001 .

[32]  Weilin Qu,et al.  Liquid Single-Phase Flow in an Array of Micro-Pin-Fins—Part II: Pressure Drop Characteristics , 2008 .

[33]  A. Koşar,et al.  TCPT-2006-096.R2: Micro Scale pin fin Heat Sinks —Parametric Performance Evaluation Study , 2007, IEEE Transactions on Components and Packaging Technologies.

[34]  P. Griffith,et al.  THE MECHANISM OF HEAT TRANSFER IN NUCLEATE POOL BOILING, PART I AND II , 1965 .

[35]  Y. Peles,et al.  Bubble Dynamics During Boiling in Enhanced Surface Microchannels , 2006, Journal of Microelectromechanical Systems.

[36]  T. Lin,et al.  Subcooled flow boiling heat transfer and associated bubble characteristics of R-134 a in a narrow annular duct , 2006 .

[37]  Santosh V. Krishnamurthy,et al.  Two-phase flow pattern transition across micropillars: Size scale effect at the microscale , 2008 .