Comparison of the 90Y-labelled glass microspheres liver radioembolisation dosimetry with the estimated dosimetry obtained from pre-treatment 99mTc-MAA SPECT images reconstructed with and without attenuation correction

ABSTRACT 90Y-labelled glass microspheres liver radioembolisation is an effective treatment for unresectable hepatic tumours. Its treatment planning is based on 99mTc-macro-aggregated albumin (MAA) single photon emission computed tomography (SPECT) imaging. However, photons interaction with human tissues may significantly compromise the accuracy of radioactivity quantification in nuclear medicine. The aim of this work is to evaluate the impact of a patient-specific attenuation correction on pre-treatment 99mTc-MAA SPECT images and, consequently, on the estimation of radioembolisation dosimetry. The methodology developed for attenuation correction was firstly validated on phantom models. Following this, a data set of eight patients was retrospectively selected from our database and the pre-treatment images were reconstructed with and without attenuation correction. Then, the liver dosimetry maps were estimated and compared with the liver dosimetry maps estimated from the post-treatment 90Y positron emission tomography images. Results show that the attenuation corrected phantom images were greatly improved, originating higher contrast, signal-to-noise ratio and contrast-to-noise ratio comparatively to non-attenuation corrected images. Attenuation corrected clinical pre-treatment images significantly increase the agreement, measured with the intraclass correlation coefficient, between predictive and post-treatment dosimetry maps comparatively to the non-attenuation corrected ones (Wilcoxon test, p = 0.008). In conclusion, a statistically significant increase in the agreement was achieved; however, poor correlation is still observed at the single-voxel level in some patients. Thus, future research should be addressed to investigate the reasons of this and manage to optimise the agreement between the predictive and post-treatment dosimetry.

[1]  Radioembolization with 90 Y-Labeled Glass Microspheres: Analytical Methods for Patient-Personalized Voxel-Based Dosimetry , 2017 .

[2]  Matthew S. Johnson,et al.  Correlation of Technetium-99m Macroaggregated Albumin and Yttrium-90 Glass Microsphere Biodistribution in Hepatocellular Carcinoma: A Retrospective Review of Pretreatment Single Photon Emission CT and Posttreatment Positron Emission Tomography/CT. , 2017, Journal of vascular and interventional radiology : JVIR.

[3]  J. Hornaday,et al.  Cancer Facts & Figures 2004 , 2004 .

[4]  C. Kuhl,et al.  The Significance of 99mTc-MAA SPECT/CT Liver Perfusion Imaging in Treatment Planning for 90Y-Microsphere Selective Internal Radiation Treatment , 2010, The Journal of Nuclear Medicine.

[5]  D. Schuster,et al.  (90)Y Radioembolization: Multimodality Imaging Pattern Approach with Angiographic Correlation for Optimized Target Therapy Delivery. , 2015, Radiographics : a review publication of the Radiological Society of North America, Inc.

[6]  Y. Rolland,et al.  Clinical impact of 99mTc-MAA SPECT/CT-based dosimetry in the radioembolization of liver malignancies with 90Y-loaded microspheres , 2015, European Journal of Nuclear Medicine and Molecular Imaging.

[7]  Clive Baldock,et al.  Investigation of the relationship between linear attenuation coefficients and CT Hounsfield units using radionuclides for SPECT. , 2008, Applied radiation and isotopes : including data, instrumentation and methods for use in agriculture, industry and medicine.

[8]  Peter Knoll,et al.  A New Approach for Scatter Removal and Attenuation Compensation from SPECT/CT Images , 2013, Iranian journal of basic medical sciences.

[9]  S. Pedemonte,et al.  GPU accelerated rotation-based emission tomography reconstruction , 2010, IEEE Nuclear Science Symposuim & Medical Imaging Conference.

[10]  Marnix G E H Lam,et al.  99mTc-Macroaggregated Albumin Poorly Predicts the Intrahepatic Distribution of 90Y Resin Microspheres in Hepatic Radioembolization , 2013, The Journal of Nuclear Medicine.

[11]  John O. Prior,et al.  Partition Model–Based 99mTc-MAA SPECT/CT Predictive Dosimetry Compared with 90Y TOF PET/CT Posttreatment Dosimetry in Radioembolization of Hepatocellular Carcinoma: A Quantitative Agreement Comparison , 2016, The Journal of Nuclear Medicine.

[12]  M. Ferrari,et al.  Impact of missing attenuation and scatter corrections on 99mTc‐MAA SPECT 3D dosimetry for liver radioembolization using the patient relative calibration methodology: A retrospective investigation on clinical images , 2018, Medical physics.

[13]  Francis R. Verdun,et al.  Phantom Validation of Tc-99m Absolute Quantification in a SPECT/CT Commercial Device , 2016, Comput. Math. Methods Medicine.

[14]  T. Walker SPECT/CT with 99mTc-MAA in Radioembolization with 90Y Microspheres in Patients with Hepatocellular Cancer , 2010 .

[15]  P. Pockros,et al.  Radioembolization with Yttrium-90 microspheres for patients with unresectable hepatocellular carcinoma. , 2015, Journal of gastrointestinal oncology.

[16]  M. A. van den Bosch,et al.  Holmium-166 radioembolization for the treatment of patients with liver metastases: design of the phase I HEPAR trial , 2010, Journal of experimental & clinical cancer research : CR.

[17]  J. Machac,et al.  Quantitative Comparison of Yttrium-90 (90 Y)-Microspheres and Technetium-99m (99m Tc)-Macroaggregated Albumin SPECT Images for Planning 90 Y Therapy of Liver Cancer , 2010, Technology in cancer research & treatment.

[18]  W. Bult,et al.  Microsphere radioembolization of liver malignancies: current developments. , 2009, The quarterly journal of nuclear medicine and molecular imaging : official publication of the Italian Association of Nuclear Medicine (AIMN) [and] the International Association of Radiopharmacology (IAR), [and] Section of the Society of....