Biomedical Implementation of Liquid Metal Ink as Drawable ECG Electrode and Skin Circuit

Background Conventional ways of making bio-electrodes are generally complicated, expensive and unconformable. Here we describe for the first time the method of applying Ga-based liquid metal ink as drawable electrocardiogram (ECG) electrodes. Such material owns unique merits in both liquid phase conformability and high electrical conductivity, which provides flexible ways for making electrical circuits on skin surface and a prospective substitution of conventional rigid printed circuit boards (PCBs). Methods Fundamental measurements of impedance and polarization voltage of the liquid metal ink were carried out to evaluate its basic electrical properties. Conceptual experiments were performed to draw the alloy as bio-electrodes to acquire ECG signals from both rabbit and human via a wireless module developed on the mobile phone. Further, a typical electrical circuit was drawn in the palm with the ink to demonstrate its potential of implementing more sophisticated skin circuits. Results With an oxide concentration of 0.34%, the resistivity of the liquid metal ink was measured as 44.1 µΩ·cm with quite low reactance in the form of straight line. Its peak polarization voltage with the physiological saline was detected as −0.73 V. The quality of ECG wave detected from the liquid metal electrodes was found as good as that of conventional electrodes, from both rabbit and human experiments. In addition, the circuit drawn with the liquid metal ink in the palm also runs efficiently. When the loop was switched on, all the light emitting diodes (LEDs) were lit and emitted colorful lights. Conclusions The liquid metal ink promises unique printable electrical properties as both bio-electrodes and electrical wires. The implemented ECG measurement on biological surface and the successfully run skin circuit demonstrated the conformability and attachment of the liquid metal. The present method is expected to innovate future physiological measurement and biological circuit manufacturing technique in a large extent.

[1]  Wei-Chun Chen,et al.  Role of Gallium-67 scintigraphy in the evaluation of occult sepsis in the medical ICU , 2012, Internal and Emergency Medicine.

[2]  P. Seligman,et al.  Treatment with gallium nitrate: Evidence for interference with iron metabolism in vivo , 1992, American journal of hematology.

[3]  R. A. Matula Electrical resistivity of copper, gold, palladium, and silver , 1979 .

[4]  V. Cherepenin,et al.  Three-dimensional EIT imaging of breast tissues: system design and clinical testing , 2002, IEEE Transactions on Medical Imaging.

[5]  Timothy L Hottel,et al.  Gallium poisoning: a rare case report. , 2012, Food and chemical toxicology : an international journal published for the British Industrial Biological Research Association.

[6]  Gert Cauwenberghs,et al.  Non-contact Low Power EEG/ECG Electrode for High Density Wearable Biopotential Sensor Networks , 2009, 2009 Sixth International Workshop on Wearable and Implantable Body Sensor Networks.

[7]  Jing Liu,et al.  Direct Writing of Flexible Electronics through Room Temperature Liquid Metal Ink , 2012, PloS one.

[8]  S. Dunne,et al.  Restorative dentistry: Dental post-operative sensitivity associated with a gallium-based restorative material , 2000, British Dental Journal.

[9]  Robert J. Taylor,et al.  Gallium Therapy: A Novel Metal-Based Antimicrobial Strategy for Potential Control of Rhodococcus equi Foal Pneumonia , 2006 .

[10]  John Aurie Dean,et al.  Lange's Handbook of Chemistry , 1978 .

[11]  H P Schwan,et al.  Alternating current electrode polarization , 1966, Biophysik.

[12]  Raeed H. Chowdhury,et al.  Epidermal Electronics , 2011, Science.

[13]  Graham A. Mills,et al.  In Situ Sensors for Monitoring the Marine Environment , 2014 .

[14]  A Korjenevsky,et al.  A 3D electrical impedance tomography (EIT) system for breast cancer detection. , 2001, Physiological measurement.

[15]  Gert Cauwenberghs,et al.  Wireless Non-contact EEG/ECG Electrodes for Body Sensor Networks , 2010, 2010 International Conference on Body Sensor Networks.

[16]  John G. Webster,et al.  The Measurement, Instrumentation and Sensors Handbook , 1998 .

[17]  Qin Zhang,et al.  Direct writing of electronics based on alloy and metal (DREAM) ink: A newly emerging area and its impact on energy, environment and health sciences , 2012 .

[18]  Lee C. Cadwallader,et al.  Gallium Safety in the Laboratory , 2003 .

[19]  T. Jung,et al.  Dry and Noncontact EEG Sensors for Mobile Brain–Computer Interfaces , 2012, IEEE Transactions on Neural Systems and Rehabilitation Engineering.

[20]  Jing Liu,et al.  Printable tiny thermocouple by liquid metal gallium and its matching metal , 2012 .

[21]  B H Brown,et al.  Electrical impedance tomography (EIT): a review , 2003, Journal of medical engineering & technology.