R/C Existing Structures with Smooth Reinforcing Bars: Experimental Behaviour of Beam-Column Joints Subject to Cyclic Lateral Loads

The paper illustrates the results of experimental tests performed on sub-assemblages of R/C (Reinforced Concrete) existing structures, designed only for gravity loads In order to estimate failure mechanisms and ductility properties, four internal and external R/C beam-column joints were built and tested. The specimens were built by using concrete with low strength and smooth reinforcing bars, without hoops into the panel zone. The tests were performed by increasing cyclic horizontal displacements up to the collapse. The experimental results show that seismic response of these kind of structures is mainly influenced by bond slips of longitudinal bars, and that the shear collapse regards external joints rather the internal ones. Failure mechanisms observed (column plastic hingings for internal joints, shear failure for external joints) point out the vulnerability of these structures due to the soft storey mechanism. The study is significant for better understanding of the inelastic seismic behavior of the R/C existing buildings with smooth bars, and for evaluating the effectiveness of the model classical assumptions.

[1]  Stefano Pampanin,et al.  RELEVANCE OF BEAM-COLUMN JOINT DAMAGE AND COLLAPSE IN RC FRAME ASSESSMENT , 2002 .

[2]  Chris G. Karayannis,et al.  Modelling exterior beam–column joints for seismic analysis of RC frame structures , 2008 .

[3]  Andrew S. Whittaker,et al.  Performance of reinforced concrete buildings during the August 17, 1999 Kocaeli, Turkey earthquake, and seismic design and construction practise in Turkey , 2003 .

[4]  Stefano Pampanin,et al.  Seismic Upgrading of 3-D Exterior R.C. Beam Column Joints Subjected To Bi-Directional Cyclic Loading Using GFP Composites, , 2007 .

[5]  Shigeru Hakuto,et al.  Retrofitting of reinforced concrete moment resisting frames. , 1995 .

[6]  Tarek H. Almusallam,et al.  Seismic Response of Interior RC Beam-Column Joints Upgraded with FRP Sheets. I: Experimental Study , 2007 .

[7]  John B. Mander,et al.  Gravity-load-designed reinforced concrete buildings - Part I: Seismic evaluation of existing construction , 1995 .

[8]  R. Park,et al.  Seismic Load Tests on Interior and Exterior Beam-Column Joints with Substandard Reinforcing Details , 2000 .

[9]  Alexander G. Tsonos,et al.  Effectiveness of CFRP-jackets and RC-jackets in post-earthquake and pre-earthquake retrofitting of beam–column subassemblages , 2008 .

[10]  Seth Stovack Kessler Piezoelectric-based in-situ damage detection of composite materials for structural health monitoring systems , 2002 .

[11]  John B. Mander,et al.  Seismic Resistance of Reinforced Concrete Frame Structures Designed for Gravity Loads: Performance of Structural System , 1995 .

[12]  A. Ghobarah,et al.  Seismic rehabilitation of beam–column joint using GFRP sheets , 2002 .

[13]  John B. Mander,et al.  Seismic Resistance of Reinforced Concrete Frame Structures Designed Only for Gravity Loads: Experimental Performance of Subassemblages , 1994 .