Fast, simple gradient delay estimation for spiral MRI

Timing delays between data acquisition and gradient transmission result in image degradation. This is especially true in spiral MRI, where delays can alter data in a nonuniform manner, generating significant artifact in the reconstructed data. The many methods that exist to mitigate these delays or measure the k‐space coordinates require long measurement times, complicated analysis, specialized phantoms or hardware, or significant changes to the sequence of interest. A fast and simple method is proposed to measure delays on each gradient channel. It requires only minimal modification to an existing spiral sequence and can be used to measure independent delays on three gradient channels and any scan subject within six sequence repetition times. The effectiveness and accuracy of this method are analyzed. Magn Reson Med 63:1683–1690, 2010. © 2010 Wiley‐Liss, Inc.

[1]  D. G. Hughes,et al.  Quantitative characterization of the eddy current fields in a 40‐cm bore superconducting magnet , 1994, Magnetic resonance in medicine.

[2]  H P Hetherington,et al.  A Method to measure arbitrary k‐space trajectories for rapid MR imaging , 1997, Magnetic resonance in medicine.

[3]  Dwight G. Nishimura,et al.  Rapid gridding reconstruction with a minimal oversampling ratio , 2005, IEEE Transactions on Medical Imaging.

[4]  James G. Pipe,et al.  Convolution kernel design and efficient algorithm for sampling density correction , 2009, Magnetic resonance in medicine.

[5]  Jurek A Nordmeyer-Massner,et al.  NMR probes for measuring magnetic fields and field dynamics in MR systems , 2008, Magnetic resonance in medicine.

[6]  Laurent Lamalle,et al.  Improved k‐space trajectory measurement with signal shifting , 2007, Magnetic resonance in medicine.

[7]  D M Spielman,et al.  Spiral imaging on a small‐bore system at 4.7t , 1995, Magnetic resonance in medicine.

[8]  D. Nishimura,et al.  Fast Three Dimensional Magnetic Resonance Imaging , 1995, Magnetic resonance in medicine.

[9]  Kensuke Sekihara,et al.  A method of measuring field-gradient modulation shapes. Application to high-speed NMR spectroscopic imaging , 1987 .

[10]  K. Pruessmann,et al.  Spatiotemporal magnetic field monitoring for MR , 2008, Magnetic resonance in medicine.

[11]  W. Dannels,et al.  Exact temporal eddy current compensation in magnetic resonance imaging systems. , 1988, IEEE transactions on medical imaging.

[12]  N G Papadakis,et al.  A general method for measurement of the time integral of variant magnetic field gradients: application to 2D spiral imaging. , 1997, Magnetic resonance imaging.

[13]  N J Pelc,et al.  Gradient characterization using a Fourier‐transform technique , 1998, Magnetic resonance in medicine.

[14]  J A Frank,et al.  Simple correction method for k-space trajectory deviations in MRI. , 1998, Journal of magnetic resonance.

[15]  Gerhard Wachutka,et al.  Robust, susceptibility-matched NMR probes for compensation of magnetic field imperfections in magnetic resonance imaging (MRI) , 2008 .

[16]  E M Stokely,et al.  A novel k‐space trajectory measurement technique , 1998, Magnetic resonance in medicine.

[17]  A. Takahashi,et al.  Compensation of multi‐dimensional selective excitation pulses using measured k‐space trajectories , 1995, Magnetic resonance in medicine.

[18]  Craig H Meyer,et al.  Estimation of k‐space trajectories in spiral MRI , 2009, Magnetic resonance in medicine.

[19]  P. Jezzard,et al.  Calibration of gradient propagation delays for accurate two‐dimensional radiofrequency pulses , 2005, Magnetic Resonance in Medicine.