Continuous glucose monitors prove highly accurate in critically ill children

IntroductionHyperglycemia is associated with increased morbidity and mortality in critically ill patients and strict glycemic control has become standard care for adults. Recent studies have questioned the optimal targets for such management and reported increased rates of iatrogenic hypoglycemia in both critically ill children and adults. The ability to provide accurate, real-time continuous glucose monitoring would improve the efficacy and safety of this practice in critically ill patients. The aim of our study is to determine if a continuous, interstitial glucose monitor will correlate with blood glucose values in critically ill children.MethodsWe evaluated 50 critically ill children age 6 weeks to 16 years old with a commercially available continuous glucose monitor (CGM; Medtronic Guardian®). CGM values and standard blood glucose (BG) values were compared. During the study, no changes in patient management were made based on CGM readings alone.ResultsForty-seven patients had analyzable CGM data. A total of 1,555 CGM and routine BG measurements were compared using Clarke error grid and Bland-Altman analysis. For all readings, 97.9% were within clinically acceptable agreement. The mean absolute relative difference between CGM and BG readings was 15.3%. For the 1,555 paired CGM and BG measurements, there is a statistically significant linear relationship between CGM values and BG (P <.0001). A high degree of clinical agreement existed in three subpopulation analyses based on age, illness severity, and support measures. This included some of our smallest patients (that is, <12 months old), those who required vasopressors, and those who were treated for critical illness hyperglycemia.ConclusionsIn one of the largest studies to date, in a highly vulnerable ICU population, CGM values have a clinically acceptable correlation with the BG values now used diagnostically and therapeutically. Our data contest the theoretical concerns posed by some regarding CGM use in the ICU. The existing medical evidence may now support a role for CGM devices in the identification and management of hyperglycemia in diverse ICU settings.

[1]  M. Rigby,et al.  A disparity between physician attitudes and practice regarding hyperglycemia in pediatric intensive care units in the United States: a survey on actual practice habits , 2010, Critical care.

[2]  James Chamberlain,et al.  Successful Use of a Single Subcutaneous Continuous Glucose Monitor Sensor for 28 Days in a Patient with Type 1 Diabetes , 2008 .

[3]  Rolf Rossaint,et al.  Intensive insulin therapy and pentastarch resuscitation in severe sepsis. , 2008, The New England journal of medicine.

[4]  M Schetz,et al.  Intensive insulin therapy in critically ill patients. , 2001, The New England journal of medicine.

[5]  Greet Van den Berghe,et al.  Intensive insulin therapy for patients in paediatric intensive care: a prospective, randomised controlled study , 2009, The Lancet.

[6]  Mary T Korytkowski,et al.  American Association of Clinical Endocrinologists and American Diabetes Association consensus statement on inpatient glycemic control. , 2009, Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists.

[7]  P. Jorens,et al.  Glucose control and use of continuous glucose monitoring in the intensive care unit: a critical review. , 2008, Current diabetes reviews.

[8]  K. Joosten,et al.  Re: Management of hyperglycemia in the pediatric intensive care unit. , 2010, Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies.

[9]  V. Nadkarni,et al.  Association of timing, duration, and intensity of hyperglycemia with intensive care unit mortality in critically ill children , 2004, Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies.

[10]  M. Rigby,et al.  A protocolized approach to identify and manage hyperglycemia in a pediatric critical care unit* , 2008, Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies.

[11]  G. Van den Berghe,et al.  Intensive insulin therapy in the medical ICU. , 2006, The New England journal of medicine.

[12]  A. Rake,et al.  Prospective detection of hyperglycemia in critically ill children using continuous glucose monitoring* , 2008, Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies.

[13]  M. Levy,et al.  Surviving Sepsis Campaign: International guidelines for management of severe sepsis and septic shock: 2008 , 2007, Intensive Care Medicine.

[14]  Michael S D Agus,et al.  The first use of live continuous glucose monitoring in patients on extracorporeal life support. , 2005, Diabetes technology & therapeutics.

[15]  R. Tasker,et al.  Outside the limits of normal blood glucose during critical illness: failed homeostasis and quantifying allostatic load. , 2010, Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies.

[16]  Lutz Heinemann,et al.  Comparison of the Numerical and Clinical Accuracy of Four Continuous Glucose Monitors , 2008, Diabetes Care.

[17]  James D Dziura,et al.  Experience with the continuous glucose monitoring system in a medical intensive care unit. , 2004, Diabetes technology & therapeutics.

[18]  Richard Hellman,et al.  American Association of Clinical Endocrinologists and American Diabetes Association consensus statement on inpatient glycemic control. , 2009, Endocrine practice : official journal of the American College of Endocrinology and the American Association of Clinical Endocrinologists.

[19]  K. Joosten,et al.  Management of hyperglycemia in the pediatric intensive care unit; implementation of a glucose control protocol , 2009, Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies.

[20]  D. Dunger,et al.  The continuous glucose monitoring sensor in neonatal intensive care , 2005, Archives of Disease in Childhood - Fetal and Neonatal Edition.

[21]  Howard Zisser,et al.  Improvement in glycemic excursions with a transcutaneous, real-time continuous glucose sensor: a randomized controlled trial. , 2006, Diabetes care.

[22]  Luc Van Gaal,et al.  Intensive Insulin Therapy in the Intensive Care Unit , 2006, Diabetes Care.

[23]  Andreas Pfützner,et al.  Evaluation of CGMS during rapid blood glucose changes in patients with type 1 diabetes. , 2006, Diabetes technology & therapeutics.

[24]  Karen Stevenson,et al.  Evaluation of a continuous glucose monitor in an unselected general intensive care population. , 2008, Critical care and resuscitation : journal of the Australasian Academy of Critical Care Medicine.

[25]  B. Bistrian,et al.  Intensive insulin therapy in critically ill patients. , 2002, The New England journal of medicine.

[26]  P. Metnitz,et al.  Impact of shock requiring norepinephrine on the accuracy and reliability of subcutaneous continuous glucose monitoring , 2009, Intensive Care Medicine.

[27]  Stephane Heritier,et al.  Intensive versus conventional glucose control in critically ill patients. , 2009, The New England journal of medicine.

[28]  Eliotte Hirshberg,et al.  Blood glucose control in critically ill adults and children: a survey on stated practice. , 2008, Chest.

[29]  Saxon Ridley Critical care. , 2003, Anaesthesia.

[30]  James Stephen Krinsley,et al.  Effect of an intensive glucose management protocol on the mortality of critically ill adult patients. , 2004, Mayo Clinic proceedings.

[31]  Jaap E Tulleken,et al.  Accuracy and feasibility of point-of-care and continuous blood glucose analysis in critically ill ICU patients , 2006, Critical care.

[32]  Johan Groeneveld,et al.  A prospective randomised multi-centre controlled trial on tight glucose control by intensive insulin therapy in adult intensive care units: the Glucontrol study , 2009, Intensive Care Medicine.

[33]  B. Frémont,et al.  SUMMARY OF SAFETY AND EFFECTIVENESS DATA , 2002 .

[34]  R. Tasker,et al.  Pilot evaluation of continuous subcutaneous glucose monitoring in children with multiple organ dysfunction syndrome* , 2009, Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies.

[35]  Peter C Laussen,et al.  Real-Time Continuous Glucose Monitoring in Pediatric Patients During and After Cardiac Surgery , 2006, Pediatrics.

[36]  T. M. Hoffman,et al.  Hyperglycemia is a marker for poor outcome in the postoperative pediatric cardiac patient* , 2006, Pediatric critical care medicine : a journal of the Society of Critical Care Medicine and the World Federation of Pediatric Intensive and Critical Care Societies.

[37]  K. Maher,et al.  Glycemic Control for Postoperative Pediatric Cardiac Patients , 2009, Pediatric Cardiology.

[38]  F. Chee,et al.  Closed-loop glucose control in critically ill patients using continuous glucose monitoring system (CGMS) in real time , 2003, IEEE Transactions on Information Technology in Biomedicine.