In vivo near-infrared dual-axis confocal microendoscopy in the human lower gastrointestinal tract.

Near-infrared confocal microendoscopy is a promising technique for deep in vivo imaging of tissues and can generate high-resolution cross-sectional images at the micron-scale. We demonstrate the use of a dual-axis confocal (DAC) near-infrared fluorescence microendoscope with a 5.5-mm outer diameter for obtaining clinical images of human colorectal mucosa. High-speed two-dimensional en face scanning was achieved through a microelectromechanical systems (MEMS) scanner while a micromotor was used for adjusting the axial focus. In vivo images of human patients are collected at 5 frames/sec with a field of view of 362×212 μm(2) and a maximum imaging depth of 140 μm. During routine endoscopy, indocyanine green (ICG) was topically applied a nonspecific optical contrasting agent to regions of the human colon. The DAC microendoscope was then used to obtain microanatomic images of the mucosa by detecting near-infrared fluorescence from ICG. These results suggest that DAC microendoscopy may have utility for visualizing the anatomical and, perhaps, functional changes associated with colorectal pathology for the early detection of colorectal cancer.

[1]  M. Harris,et al.  Fiber-optic laser scanning confocal microscope suitable for fluorescence imaging. , 1994, Applied optics.

[2]  G. Kino,et al.  CHAPTER 4 – Phase Imaging , 1996 .

[3]  G. Kino,et al.  Confocal Scanning Optical Microscopy and Related Imaging Systems , 1996 .

[4]  G. Kino,et al.  Silicon-micromachined scanning confocal optical microscope , 1998 .

[5]  A. Jemal,et al.  Global cancer statistics , 2011, CA: a cancer journal for clinicians.

[6]  Thomas D. Wang,et al.  Dual-axis confocal microscope for high-resolution in vivo imaging. , 2003, Optics letters.

[7]  E. Vicaut,et al.  Fibered Confocal Fluorescence Microscopy (Cell-viZio™) Facilitates Extended Imaging in the Field of Microcirculation , 2004, Journal of Vascular Research.

[8]  Olav Solgaard,et al.  Fast-scanning two-photon fluorescence imaging based on a microelectromechanical systems two- dimensional scanning mirror. , 2006, Optics letters.

[9]  Wibool Piyawattanametha,et al.  Two-axis MEMS Scanning Catheter for Ultrahigh Resolution Three-dimensional and En Face Imaging. , 2007, Optics express.

[10]  Thomas D. Wang,et al.  Miniature near-infrared dual-axes confocal microscope utilizing a two-dimensional microelectromechanical systems scanner. , 2007, Optics letters.

[11]  W. Piyawattanametha,et al.  Two-Dimensional MEMS Scanner for Dual-Axes Confocal Microscopy , 2007, Journal of Microelectromechanical Systems.

[12]  Rebecca Richards-Kortum,et al.  Optical imaging for cervical cancer detection: solutions for a continuing global problem , 2008, Nature Reviews Cancer.

[13]  S. Cross,et al.  In vivo confocal laser scanning chromo‐endomicroscopy of colorectal neoplasia: changing the technological paradigm , 2008, Histopathology.

[14]  Thomas D. Wang,et al.  Efficient rejection of scattered light enables deep optical sectioning in turbid media with low-numerical-aperture optics in a dual-axis confocal architecture. , 2008, Journal of biomedical optics.

[15]  Christopher H Contag,et al.  Three-dimensional in vivo imaging by a handheld dual-axes confocal microscope. , 2008, Optics express.

[16]  W. Piyawattanametha,et al.  3-D Near-Infrared Fluorescence Imaging Using an MEMS-Based Miniature Dual-Axis Confocal Microscope , 2009, IEEE Journal of Selected Topics in Quantum Electronics.

[17]  John Kenneth Salisbury,et al.  In Vivo Micro-Image Mosaicing , 2011, IEEE Transactions on Biomedical Engineering.