Surgical Strategy and Techniques for Low-Profile Dorsal Plating in Treating Dorsally Displaced Unstable Distal Radius Fractures

Abstract Background The low-profile dorsal locking plating (DLP) technique is useful for treating dorsally comminuted intra-articular distal radius fractures; however, due to the complications associated with DLP, the technique is not widely used. Methods A retrospective review of 24 consecutive cases treated with DLP were done. Results All cases were classified into two types by surgical strategy according to the fracture pattern. In type 1, there is a volar fracture line distal to the watershed line in the dorsally displaced fragment, and this type is treated by H-framed DLP. In type 2, the displaced dorsal die-punch fragment is associated with a minimally displaced styloid shearing fracture or a transverse volar fracture line. We found that the die-punch fragment was reduced by the buttress effect of small l-shaped DLP after stabilization of the styloid shearing for the volar segment by cannulated screws from radial styloid processes. At 6 months after surgery, outcomes were good or excellent based on the modified Mayo wrist scores with no serious complications except one case. The mean range of motion of each type was as follows: the palmar flexion was 50, 65 degrees, dorsiflexion was 70, 75 degrees, supination was 85, 85 degrees, and pronation was 80, 80 degrees; in type 1 and 2, respectively. Conclusion DLP is a useful technique for the treatment of selected cases of dorsally displaced, comminuted intra-articular fractures of the distal radius with careful soft tissue coverage.

[1]  J. Jupiter,et al.  Stabilisation of distal radius fractures: Lessons learned and future directions. , 2016, Injury.

[2]  David M. Brogan,et al.  Management of Severely Comminuted Distal Radius Fractures. , 2015, The Journal of hand surgery.

[3]  P. Blazar,et al.  The use of a single volar locking plate for AO C3-type distal radius fractures , 2015, Hand.

[4]  M. Bozik,et al.  Is an implant removal after dorsal plating of distal radius fracture always needed? , 2015, Bratislavske lekarske listy.

[5]  Jonas L. Matzon,et al.  Hardware-related complications after dorsal plating for displaced distal radius fractures. , 2014, Orthopedics.

[6]  N. Haas,et al.  Complication rates and reduction potential of palmar versus dorsal locking plate osteosynthesis for the treatment of distal radius fractures , 2014, Journal of Orthopaedics and Traumatology.

[7]  Scott W Wolfe,et al.  Distal radius fractures: strategic alternatives to volar plate fixation. , 2014, Instructional course lectures.

[8]  M. Fok,et al.  Volar Plate Fixation of Intra-Articular Distal Radius Fractures: A Retrospective Study , 2013, Journal of Wrist Surgery.

[9]  Toshitaka Nakamura,et al.  Extensor pollicis longus tendon ruptures after the use of volar locking plates for distal radius fractures. , 2013, Hand surgery : an international journal devoted to hand and upper limb surgery and related research : journal of the Asia-Pacific Federation of Societies for Surgery of the Hand.

[10]  C. Goldfarb,et al.  Dorsal locked plate fixation of distal radius fractures. , 2013, The Journal of hand surgery.

[11]  W. Geissler* Management Distal Radius and Distal Ulnar Fractures with Fragment Specific Plate , 2013, Journal of wrist surgery.

[12]  Sung-whan Cho,et al.  The effects of a displaced dorsal rim fracture on outcomes after volar plate fixation of a distal radius fracture. , 2012, Injury.

[13]  M. Tyllianakis,et al.  Long-term results of dorsally displaced distal radius fractures treated with the pi-plate: is hardware removal necessary? , 2011, Orthopedics.

[14]  L. Audigé,et al.  Comparison of angle stable plate fixation approaches for distal radius fractures. , 2011, Injury.

[15]  S. Tabrizi,et al.  Complications of low-profile dorsal versus volar locking plates in the distal radius: a comparative study. , 2010, The Journal of hand surgery.

[16]  C. Goldfarb,et al.  Dorsal fixation of intra-articular distal radius fractures using 2.4-mm locking plates. , 2009, Techniques in hand & upper extremity surgery.

[17]  R. Seshadri,et al.  The outcome of intra-articular distal radius fractures treated with fragment-specific fixation. , 2006, The Journal of hand surgery.

[18]  J. Jupiter,et al.  Dorsal plating for distal radius fractures. , 2005, Hand clinics.

[19]  R. Medoff Essential radiographic evaluation for distal radius fractures. , 2005, Hand clinics.

[20]  P. Regazzoni,et al.  [Management of complex distal radius fractures]. , 2003, Zentralblatt fur Chirurgie.

[21]  Y. Kiyoshige Condylar Stabilizing Technique with AO/ASIF Distal Radius Plate for Colles' Fracture Associated with Osteoporosis. , 2002, Techniques in hand & upper extremity surgery.

[22]  P. Regazzoni,et al.  The double plating technique for distal radius fractures. , 2000, Techniques in hand & upper extremity surgery.

[23]  Jesse B. Jupiter,et al.  Complex Articular Fractures of the Distal Radius: Classification and Management , 1997, The Journal of the American Academy of Orthopaedic Surgeons.