Design and engineering aspects of a high resolution positron tomograph for small animal imaging

Describes the Sherbrooke positron emission tomograph, a very high resolution device dedicated to dynamic imaging of small laboratory animals. Its distinctive features are: small discrete scintillation detectors based on avalanche photodiodes (APD) to achieve uniform, isotropic, very high spatial resolution; parallel processing for low deadtime and high count rate capability; multispectral data acquisition hardware to improve sensitivity and scatter correction; modularity to allow design flexibility and upgradability. The system implements the "clam-shell" sampling scheme and a rotating rod transmission source. All acquisition parameters can be adjusted under computer control. Temperature stability at the detector site is ensured by the use of thermoelectric modules. The initial system consists of one layer of 256 modules (two rings of detectors) defining 3 image slices in a 118 mm diameter by 10.5 mm thick field. The axial field can be extended to 50 mm using 4 layers of modules (8 rings of detectors). The design constraints and engineering aspects of an APD-based PET scanner are reviewed and preliminary results are reported. >

[1]  C. J. Thompson,et al.  The Effect of Live Time in Components of a Positron Tomograph on Image Quantification , 1987, IEEE Transactions on Nuclear Science.

[2]  R. Lecomte,et al.  Potentials of multispectral acquisition in positron emission tomography , 1992, IEEE Conference on Nuclear Science Symposium and Medical Imaging.

[3]  E. Hoffman,et al.  Performance standards in positron emission tomography. , 1991, Journal of nuclear medicine : official publication, Society of Nuclear Medicine.

[4]  Roger Lecomte,et al.  A stationary sampling scheme for multilayer positron tomographs , 1993, IEEE Trans. Medical Imaging.

[5]  Roger Lecomte,et al.  Tuning of avalanche photodiode PET camera , 1992 .

[6]  Roger Lecomte,et al.  Status of BGO-avalanche photodiode detectors for spectroscopic and timing measurements , 1989 .

[7]  R. Lecomte,et al.  Front-end processing electronics for a PET tomograph based on BGO-avalanche photodiode detectors , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[8]  M.E. Casey,et al.  A low-noise, wideband, integrated CMOS transimpedance preamplifier for photodiode applications , 1991, Conference Record of the 1991 IEEE Nuclear Science Symposium and Medical Imaging Conference.

[9]  Roger Lecomte,et al.  Timing performance of scintillators read out by silicon avalanche photodiodes , 1990 .

[10]  Roger Lecomte,et al.  High resolution positron emission tomography with a prototype camera based on solid state scintillation detectors , 1990 .

[11]  W. W. Moses,et al.  Empirical observation of resolution degradation in positron emission tomographs utilizing block detectors , 1994 .

[12]  Karsten P. Ulland,et al.  Vii. References , 2022 .

[13]  R. Lecomte,et al.  Performance Characteristics of BGO-Silicon Avalanche Photodiode Detectors for PET , 1985, IEEE Transactions on Nuclear Science.

[14]  R Lecomte,et al.  Study of the resolution performance of an array of discrete detectors with independent readouts for positron emission tomography. , 1991, IEEE transactions on medical imaging.

[15]  Roger Lecomte,et al.  Recent results in scintillation detection with silicon avalanche photodiodes , 1990 .

[16]  R. Lecomte,et al.  A Bismuth Germanate-Avalanche Photodiode Module Designed for Use in High Resolution Positron Emission Tomography , 1986, IEEE Transactions on Nuclear Science.

[17]  R. Lecomte,et al.  Ultra-Low Noise Charge Sensitive Preamplifier for Scintillation Detection with Avalanche Photodiodes in PET Applications , 1987, IEEE Transactions on Nuclear Science.

[18]  Roger Lecomte,et al.  A PET camera simulator with multispectral data acquisition capabilities , 1992 .