Simultaneous derivatization and extraction of anilines in waste water with dispersive liquid-liquid microextraction followed by gas chromatography-mass spectrometric detection.

The one-step derivatization and extraction technique for the determination of anilines in river water by dispersive liquid-liquid microextraction (DLLME) is presented. In this method the anilines are extracted by DLLME and derivatized with pentafluorobenzaldehyde (PFBAY) in aqueous solution simultaneously. In this derivatization/extraction method, 0.5 ml acetone (disperser solvent) containing 10 microl chlorobenzene (extraction solvent) and 30 g/l pentafluorobenzaldehyde (PFBAY) dissolved in methanol was rapidly injected by syringe into 5 ml aqueous sample (pH 4.6). Within 20 min the analytes extracted and derivatized were almost finished. After centrifugation, 2 microl sedimented phase containing enriched analytes was determined by GC-MS. The effects of extraction and disperser solvent type and their volume, pH value of sample solution, derivatization and extraction time, derivatization and extraction temperature were investigated. Linearity in this developed method was ranging from 0.25 to 70 microg/l, and the correlation coefficients (R2) were between 0.9955 and 0.9989, and reasonable reproducibility ranging from 5.8 to 11.8% (n=5). Method detection limits (MDLs) ranged from 0.04 to 0.09 microg/l (n=5).

[1]  H. Kataoka,et al.  Derivatization reactions for the determination of amines by gas chromatography and their applications in environmental analysis. , 1996, Journal of chromatography. A.

[2]  D. Djozan,et al.  Liquid chromatographic determination of aniline and derivatives in environmental waters at nanogram per litre levels using fluorescamine pre-column derivatization , 1995 .

[3]  M. Hosseini,et al.  Determination of chlorophenols in water samples using simultaneous dispersive liquid-liquid microextraction and derivatization followed by gas chromatography-electron-capture detection. , 2007, Journal of chromatography. A.

[4]  Hian Kee Lee,et al.  Liquid-Phase Microextraction in a Single Drop of Organic Solvent by Using a Conventional Microsyringe , 1997 .

[5]  E. Papadopoulou-mourkidou,et al.  Development of an automated on-line solid-phase extraction-high-performance liquid chromatographic method for the analysis of aniline, phenol, caffeine and various selected substituted aniline and phenol compounds in aqueous matrices. , 2000, Journal of chromatography. A.

[6]  E. Benfenati,et al.  Determination of aromatic amines by solid-phase microextraction and gas chromatography-mass spectrometry in water samples , 1997 .

[7]  M. R. Jamali,et al.  Determination of Trihalomethanes in Drinking Water by Dispersive Liquid–Liquid Microextraction then Gas Chromatography with Electron-Capture Detection , 2007 .

[8]  G. G. Stokes "J." , 1890, The New Yale Book of Quotations.

[9]  M. R. Jamali,et al.  Part-per-trillion determination of chlorobenzenes in water using dispersive liquid-liquid microextraction combined gas chromatography-electron capture detection. , 2007, Talanta.

[10]  L. Fishbein Chromatography of environmental hazards , 1975 .

[11]  R. Luthy,et al.  Oxidation of aniline and other primary aromatic amines by manganese dioxide , 1990 .

[12]  R. Hites,et al.  Composition, treatment efficiency, and environmental significance of dye manufacturing plant effluents , 1977 .

[13]  J. Jen,et al.  Determination of aniline in silica gel sorbent by one-step in situ microwave-assisted desorption coupled to headspace solid-phase microextraction and GC-FID. , 2004, Talanta.

[14]  M. Dalene,et al.  Trace analysis of amines and isocyanates using glass capillary gas chromatography and selective detection IV. Determination of free aromatic amines using nitrogen-selective detection , 1985 .

[15]  M. Porthault,et al.  Determination of phenylurea herbicides in water using microcolumn high performance liquid chromatography with UV and electrochemical detection , 1993 .

[16]  J. Lehotay,et al.  Simultaneous HPLC determination of phenylurea herbicides and their corresponding anilines in water after on-line preconcentration , 1994 .

[17]  R. B. Geerdink Determination of aniline derivatives by high-performance liquid chromatography with fluorescence detection , 1988 .

[18]  A. T. James,et al.  Gas-liquid chromatography; a technique for the analysis and identification of volatile materials. , 1954, British medical bulletin.