Inconsistent correlation between aerobic bacterial surface and air counts in operating rooms with ultra clean laminar air flows: proposal of a new bacteriological standard for surface contamination.

The relationship between surface contamination (cfus/m2/h) with particles carrying aerobic bacteria and corresponding air contamination rates (cfus/m3) was evaluated in operating rooms (OR) equipped with ultra clean vertical or horizontal laminar airflow (LAF). For the evaluation we collected data during strictly standardized sham operations using non-woven disposable or cotton clothing. Air contamination in the wound and instrument areas (Casella slit sampler) was related to the surface contamination rate (settle plates) in the same areas and in addition, on the patient chest. Typically, the mean surface counts were 20-70 cfus/m2/h and the air counts 1-2 cfus/m3 in disposable clothing experiments, whilst the use of cotton clothing resulted in higher counts of 100-200 cfus/m2/h (wound P > 0.05, patient P > 0.05, instruments P < 0.01) and 4 cfus/m3 (P < 0.02-0.001). In the vertical LAF, taking both disposable and cotton clothing operations together, the surface and air contamination rates (surface/air ratio SAR) were highly correlated (P = 0.02-0.004) and the ratio varied between 18:1 and 50:1 with a mean for wound air of 36:1. Using only disposable clothing in the vertical LAF, the number of significant correlations was reduced. With cotton clothing experiments in vertical LAF and in the horizontal LAF using disposable clothing, no significant correlation between surface and air contamination was found. The wide variation of SAR values and the inconsistent relationship between surface and air counts indicates that measurement of OR air contamination represents an unhelpful method for assessment of surgical site contamination in LAF units. We propose instead that colony counts on sedimentation plates is a clinically more relevant indicator of bacterial OR contamination in LAF units. In addition to the current bacteriological standard for ultra clean OR air of (< 10 cfus/m3) we suggest a corresponding standard for the surface contamination rate of < 350 cfus/m2/h.

[1]  B Friberg,et al.  Inefficiency of upward displacement operating theatre ventilation. , 1996, The Journal of hospital infection.

[2]  J. Tinkler,et al.  The importance of airborne bacterial contamination of wounds. , 1982, The Journal of hospital infection.

[3]  Sepsis after total hip or knee joint replacement in relation to airborne contamination , 1983 .

[4]  G. Laurell,et al.  The relative importance of the routes and sources of wound contamination during general surgery. II. Airborne. , 1991, The Journal of hospital infection.

[5]  W Whyte,et al.  In support of settle plates. , 1996, PDA journal of pharmaceutical science and technology.

[6]  G. J. Taylor,et al.  Infection and interposition between ultraclean air source and wound. , 1993, The Journal of bone and joint surgery. British volume.

[7]  A. Hambraeus,et al.  Aerobiology in the operating room--a review. , 1988, The Journal of hospital infection.

[8]  O M Lidwell,et al.  Suggested bacteriological standards for air in ultraclean operating rooms. , 1983, The Journal of hospital infection.

[9]  B E Friberg,et al.  Zoned vertical ultraclean operating room ventilation. A novel concept making long side walls unnecessary. , 1996, Acta orthopaedica Scandinavica.

[10]  M. Shaffer HEALTH LABORATORY SCIENCE , 1964 .

[11]  W. Whyte Sterility assurance and models for assessing airborne bacterial contamination. , 1986, Journal of parenteral science and technology : a publication of the Parenteral Drug Association.

[12]  B Friberg,et al.  Correlation between surface and air counts of particles carrying aerobic bacteria in operating rooms with turbulent ventilation: an experimental study. , 1999, The Journal of hospital infection.

[13]  O M Lidwell,et al.  Airborne contamination of wounds in joint replacement operations: the relationship to sepsis rates. , 1983, The Journal of hospital infection.