Nano-HPLC-inductively coupled plasma mass spectrometry for arsenic speciation

A nano-high performance liquid chromatography-inductively coupled plasma mass spectrometry (nano-HPLC-ICPMS) method is developed, using a demountable direct injection high efficiency nebulizer (d-DIHEN), to reduce sample and mobile phase consumption, minimize organic waste generation, decrease analysis time, and enhance separation efficiency. A HPLC column (50 mm × 0.3 mm id), packed with 3.5 μm C18 material, is explored for chromatographic separation of five arsenic species naturally present in the environment or introduced as a pollutant: sodium (meta)arsenite [As(III)], arsenic acid [As(V)], dimethylarsenic acid (DMA), disodium methylarsenate (MA), and p-arsanilic acid (p-ASA). A fast chromatographic separation of five arsenic species is achieved in less than 12 min at a solution flow rate of 0.9 μL min−1 using a 50 nL sample injection. The HPLC-ICPMS interface provides well defined flow injection profiles at various concentrations, giving a correlation coefficient of 0.999 for each individual arsenic species calibration curve. Precision values for peak height and area of five arsenic species range from 0.5 to 6.5% RSD and absolute detection limits are within 0.4 to 5.4 pg arsenic, which are comparable to previously reported data at higher solution uptake rates (20 μL min−1 to 1 mL min−1) and larger sample injection volumes (20–100 μL).

[1]  O. Shuvaeva,et al.  Arsenic Speciation in Waters Using HPLC with Graphite Furnace Atomic Absorption Spectrometry as Detector , 2001 .

[2]  J. McLean,et al.  A direct injection high efficiency nebulizer interface for microbore high-performance liquid chromatography-inductively coupled plasma mass spectrometry , 2001 .

[3]  J. McLean,et al.  A direct injection high-efficiency nebulizer for inductively coupled plasma mass spectrometry. , 1998, Analytical chemistry.

[4]  J. Yoshinaga,et al.  Determination of arsenic compounds by high-performance liquid chromatography-ultrasonic nebulizer-high power nitrogen-microwave-induced plasma mass spectrometry: an accepted coupling. , 2000, Analytical Chemistry.

[5]  J. McLean,et al.  Ultratrace and isotope analysis of long-lived radionuclides by inductively coupled plasma quadrupole mass spectrometry using a direct injection high efficiency nebulizer. , 1999, Analytical chemistry.

[6]  Wei-Chang Tseng,et al.  Automated, continuous, and dynamic speciation of urinary arsenic in the bladder of living organisms using microdialysis sampling coupled on-line with high performance liquid chromatography and hydride generation atomic absorption spectrometry. , 2002, The Analyst.

[7]  S. Ito,et al.  Capillary high-performance liquid chromatography/electrospray ion trap time-of-flight mass spectrometry using a novel nanoflow gradient generator. , 2005, Journal of chromatography. A.

[8]  A. Cappiello,et al.  Nano-high-performance liquid chromatography–electron ionization mass spectrometry approach for environmental analysis , 2003 .

[9]  Kevin A Francesconi,et al.  Determination of arsenic species: a critical review of methods and applications, 2000-2003. , 2004, The Analyst.

[10]  G. Pershagen The epidemiology of human arsenic exposure , 1983 .

[11]  Karl Mechtler,et al.  An improved method for tracking and reducing the void volume in nano HPLC–MS with micro trapping columns , 2003, Analytical and bioanalytical chemistry.

[12]  G. Millward,et al.  Determination of arsenic species in fish, crustacean and sediment samples from Thailand using high performance liquid chromatography (HPLC) coupled with inductively coupled plasma mass spectrometry (ICP-MS). , 2004, Journal of environmental monitoring : JEM.

[13]  M. Potin-Gautier,et al.  Speciation analysis of arsenic in environmental solids Reference Materials by high-performance liquid chromatography–hydride generation–atomic fluorescence spectrometry following orthophosphoric acid extraction , 2001 .

[14]  P. Schmitt‐Kopplin,et al.  A simple and robust set-up for on-column sample preconcentration – nano-liquid chromatography – electrospray ionization mass spectrometry for the analysis of N-acylhomoserine lactones , 2004, Analytical and bioanalytical chemistry.

[15]  Development of a nebulizer for a sheathless interfacing of NanoHPLC and ICPMS. , 2006, Analytical chemistry.

[16]  McLean,et al.  A large bore-direct injection high efficiency nebulizer for inductively coupled plasma spectrometry , 2000, Analytical chemistry.

[17]  S. Pergantis,et al.  Determination of Ten Organoarsenic Compounds Using Microbore High-performance Liquid Chromatography Coupled With Electrospray Mass Spectrometry–Mass Spectrometry , 1997 .

[18]  J. Szpunar,et al.  Selenopeptide mapping in a selenium-yeast protein digest by parallel nanoHPLC-ICP-MS and nanoHPLC-electrospray-MS/MS after on-line preconcentration , 2006 .

[19]  F. Vanhaecke,et al.  Speciation of six arsenic compounds using high-performance liquid chromatography inductively coupled plasma mass spectrometry with sample introduction by thermospray nebulization , 1997 .

[20]  J. McLean,et al.  Nebulizer diagnostics: fundamental parameters, challenges, and techniques on the horizon , 1998 .

[21]  S. Pergantis,et al.  Speciation of arsenic animal feed additives by microbore high-performance liquid chromatography with inductively coupled plasma mass spectrometry. , 1997, The Analyst.

[22]  R. Cornelis,et al.  Arsenic speciation in chinese seaweeds using HPLC-ICP-MS and HPLC-ES-MS. , 2002, The Analyst.

[23]  H. Emons,et al.  Speciation of arsenic compounds by ion-exchange HPLC-ICP-MS with different nebulizers , 2000 .

[24]  A. Montaser,et al.  Direct injection high efficiency nebulizer-inductively coupled plasma mass spectrometry for analysis of petroleum samples , 2003 .

[25]  E. Larsen,et al.  Selective arsenic speciation analysis of human urine reference materials using gradient elution ion-exchange HPLC-ICP-MS , 2004 .

[26]  K. Liber,et al.  Determination of five arsenic species in aqueous samples by HPLC coupled with a hexapole collision cell ICP-MS , 2002 .

[27]  S. Hirata,et al.  Determination of Arsenic Species in Marine Samples by HPLC-ICP-MS , 2006, Analytical sciences : the international journal of the Japan Society for Analytical Chemistry.

[28]  Á. Bereczky,et al.  Epidemiological studies on human subjects exposed to arsenic in drinking water in Southeast Hungary , 2006, Archives of Toxicology.

[29]  Y. C. Sun,et al.  Comparative study on conventional and low-flow nebulizers for arsenic speciation by means of microbore liquid chromatography with inductively coupled plasma mass spectrometry. , 2003, Journal of chromatography. A.

[30]  T. A. Butler,et al.  Effect of valence state on ICP-OES value assignment of SRM 3103a arsenic spectrometric solution. , 2006, Analytical chemistry.

[31]  J. Caruso,et al.  Arsenic and its speciation analysis using high-performance liquid chromatography and inductively coupled plasma mass spectrometry. , 2004, Journal of chromatography. A.

[32]  J. Goldsmith,et al.  Evaluation of health implications of elevated arsenic in well water , 1972 .

[33]  F. Bressolle,et al.  Arsenic speciation in humans and food products: a review. , 1999, Journal of chromatographic science.

[34]  Jason A. Day,et al.  A study of method robustness for arsenic speciation in drinking water samples by anion exchange HPLC-ICP-MS , 2002, Analytical and bioanalytical chemistry.

[35]  X. Le,et al.  Arsenic speciation analysis. , 2002, Talanta.

[36]  W. Lehmann,et al.  Modified direct injection high efficiency nebulizer with minimized dead volume for the analysis of biological samples by micro- and nano-LC-ICP-MS , 2002 .

[37]  A. Montaser,et al.  Reduction of molecular ion interferences with hexapole collision cell in direct injection nebulization–inductively coupled plasma mass spectrometry , 2003 .

[38]  J. Caruso,et al.  Comparison of four nebulizer–spray chamber interfaces for the high-performance liquid chromatographic separation of arsenic compounds using inductively coupled plasma mass spectrometric detection , 1998 .

[39]  J. Ng Environmental contamination of arsenic and its toxicological impact on humans , 2005 .

[40]  Helmut E Meyer,et al.  Multidimensional nano-HPLC for analysis of protein complexes , 2003, Journal of the American Society for Mass Spectrometry.

[41]  S. Pergantis,et al.  High-speed separation of arsenic compounds using narrow-bore high-performance liquid chromatography on-line with inductively coupled plasma mass spectrometry , 2000 .