Framework for Threat Based Failure Rates in Transmission System Operation

Reliability of electrical transmission systems is presently managed by applying the deterministic N-1 criterion, or some variant thereof. This means that transmission systems are designed with at least one level of redundancy, regardless of the cost of doing so, or the severity of the risks they mitigate. In an operational context, the N-1 criterion provides a reliability target but it fails to accurately capture the dynamic nature of shortterm threats to transmission systems. Ongoing research aims to overcome this shortcoming by proposing new probabilistic reliability criteria. Such new criteria are anticipated to rely heavily on component failure rate calculations. This paper provides a threat modelling framework, using the Icelandic transmission system as an example, highlighting the need for improved data collection and failure rate modelling. The feasibility of using threat credibility indicators to achieve spatio-temporal failure rates, given minimal data, is explored in a case study of the Icelandic transmission system. The paper closes with a discussion on the assumptions and simplifications that are implicitly made in the formulation, and the additional work required for such an approach to be included in existing practices. Specifically, this paper is concerned only with short term and real-time management of electrical transmission systems.

[1]  A. S. Richardson A study of galloping conductors on a 230 kV transmission line , 1991 .

[2]  Lasse Makkonen,et al.  Estimation of wet snow accretion on structures , 1989 .

[3]  F. S. Young,et al.  Estimating Lightning Performance of Transmission Lines , 1964 .

[4]  Lennart Söder,et al.  A computational framework for risk-based power systems operations under uncertainty. Part I: Theory , 2015 .

[5]  M. Bebbington,et al.  Quantifying volcanic ash fall hazard to electricity infrastructure , 2008 .

[6]  Pierre-Etienne Labeau,et al.  Transmission Grid Security: A PSA Approach , 2011 .

[7]  Rui Pestana,et al.  Historical data analysis of lightning and its relation with the Portuguese Transmission system outages , 2009, 2009 IEEE Bucharest PowerTech.

[8]  Helgi Björnsson,et al.  Jökulhlaups in Iceland: prediction, characteristics and simulation , 1992, Annals of Glaciology.

[9]  Helgi Björnsson Jökulhlaups in Iceland: prediction, characteristics and simulation , 1992, Annals of Glaciology.

[10]  I. Kamwa,et al.  Causes of the 2003 major grid blackouts in North America and Europe, and recommended means to improve system dynamic performance , 2005, IEEE Transactions on Power Systems.

[11]  Hálfdán Ágústsson,et al.  Modeling Wet Snow Accretion on Power Lines: Improvements to Previous Methods Using 50 Years of Observations , 2013 .

[12]  A. B. Svendsen,et al.  Abstract representation of power system networks as a function of regularity properties , 2014 .

[13]  B. Stott Optimal Power Flow — Basic Requirements for Real-Life Problems and their Solutions , 2012 .

[14]  Federico Silvestro,et al.  Operational Risk Assessment and control: A probabilistic approach , 2010, 2010 IEEE PES Innovative Smart Grid Technologies Conference Europe (ISGT Europe).

[15]  Olav Slaymaker,et al.  Jökulhlaups in Iceland : sources, release and drainage , 2017 .

[16]  R. Sparks,et al.  Forecasting volcanic eruptions , 2003 .

[17]  D. Tarboton,et al.  Utah Energy Balance Snow Accumulation and Melt Model (UEB) , 1996 .

[18]  Anil Pahwa,et al.  Modeling Weather-Related Failures of Overhead Distribution Lines , 2006, IEEE Transactions on Power Systems.

[19]  Manolis K. Georgoulis,et al.  Toward an Efficient Prediction of Solar Flares: Which Parameters, and How? , 2013, Entropy.

[20]  Uday Kumar,et al.  Quality and Reliability Engineering: Trends and Future Directions , 2018, J. Univers. Comput. Sci..

[21]  Wenyuan Li,et al.  Probabilistic Reliability Assessment of Power System Operations , 2008 .

[22]  Paul Charbonneau,et al.  Predictive Capabilities of Avalanche Models for Solar Flares , 2014, 1406.6523.

[23]  Nader Samaan,et al.  Reliability assessment of electric power systems using genetic algorithms , 2004 .

[24]  P. Pourbeik,et al.  Review of the Current Status of Tools and Techniques for Risk-Based and Probabilistic Planning in Power Systems , 2011 .

[25]  Árni Jón Elíasson,et al.  Comparison of ice accumulation on simplex and duplex conductors in parallel overhead transmission lines in Iceland , 2015 .

[26]  Roy Billinton,et al.  Reliability evaluation of engineering systems : concepts and techniques , 1992 .

[27]  A. B. Svendsen,et al.  Analyses of delivery reliability in power systems , 2014 .

[28]  Jan A. Foosnæs,et al.  Developing indicators for monitoring vulnerability of power lines - case studies , 2013 .

[29]  F. P. Maciel Barbosa,et al.  The main causes of incidents in the Portuguese Transmission System — Their characterization and how they can be used for risk assessment , 2009, 2009 6th International Conference on the European Energy Market.

[30]  R. Billinton,et al.  Reliability Cost/Worth Assessment of Distribution Systems Incorporating Time Varying Weather Conditions and Restoration Resources , 2001, IEEE Power Engineering Review.

[31]  Helgi Björnsson,et al.  Changes in jökulhlaup sizes in Grímsvötn, Vatnajökull, Iceland, 1934-91, deduced from in-situ measurements of subglacial lake volume , 1995 .

[32]  Wasyl Janischewskyj,et al.  IEEE working group report. Estimating lightning performance of transmission lines. II: Updates to analytical models , 1993 .

[33]  J.D. McCalley,et al.  Contingency Probability Estimation Using Weather and Geographical Data for On-Line Security Assessment , 2006, 2006 International Conference on Probabilistic Methods Applied to Power Systems.

[34]  Lasse Makkonen,et al.  Models for the growth of rime, glaze, icicles and wet snow on structures , 2000, Philosophical Transactions of the Royal Society of London. Series A: Mathematical, Physical and Engineering Sciences.

[35]  Ólafur Rögnvaldsson,et al.  TOWARDS A METHOD FOR ESTIMATING THE RISK OF WET SNOW ICING IN A MOUNTAINOUS REGION , 2007 .

[36]  David M. Schultz,et al.  On the Use of Indices and Parameters in Forecasting Severe Storms , 2006, E-Journal of Severe Storms Meteorology.

[37]  Oddbjorn Gjerde,et al.  Risk and vulnerability analysis of power systems including extraordinary events , 2011, 2011 IEEE Trondheim PowerTech.

[38]  R. Billinton,et al.  Application of adverse and extreme adverse weather: modelling in transmission and distribution system reliability evaluation , 2006 .

[39]  Å. Holmgren A Framework for Vulnerability Assessment of Electric Power Systems , 2007 .

[40]  Susana Alexandra Barros de Almeida Portuguese transmission grid incidents risk assessment , 2010 .

[41]  Jonas Eliasson,et al.  Probabilistic model for eruptions and associated flood events in the Katla caldera, Iceland , 2006 .

[42]  E. Kuusisto,et al.  Snow accumulation and snowmelt in Finland , 1984 .

[43]  Kunming,et al.  Short-Term Reliability Evaluation of Transmission System Using Lightning Strike Probability Prediction , 2014 .

[44]  Sydulu Maheswarapu,et al.  Security Constraint Optimal Power Flow (SCOPF) – A Comprehensive Survey , 2010 .

[45]  John H G Macdonald,et al.  Misconceptions and Generalizations of the Den Hartog Galloping Criterion , 2014 .

[46]  Takashi Ishihara,et al.  Galloping response prediction of ice-accreted transmission lines , 2008 .

[47]  Kathleen F. Jones,et al.  Computer Model of Atmospheric Ice Accretion on Transmission Lines , 1991 .

[48]  David G. Tarboton,et al.  Sub-grid parameterization of snow distribution for an energy and mass balance snow cover model , 1999 .

[49]  Robert J. Thomas,et al.  A stochastic, contingency-based security-constrained optimal power flow for the procurement of energy and distributed reserve , 2013, Decis. Support Syst..

[50]  Pei Yu,et al.  FINITE ELEMENT MODELLING OF TRANSMISSION LINE GALLOPING , 1995 .

[51]  Fushuan Wen,et al.  A chance constrained programming approach to transmission system expansion planning , 2005 .

[52]  Helgi Björnsson,et al.  Megaflooding on Earth and Mars: Jökulhlaups in Iceland: sources, release and drainage , 2009 .

[53]  D. Jayaweera,et al.  Value of Security: Modeling Time-Dependent Phenomena and Weather Conditions , 2002, IEEE Power Engineering Review.

[54]  J. Ramos,et al.  State-of-the-art, challenges, and future trends in security constrained optimal power flow , 2011 .

[55]  Ghyslaine McClure,et al.  Modeling the structural dynamic response of overhead transmission lines , 2003 .

[56]  S. Goodman,et al.  Forecasting Lightning Threat Using Cloud-Resolving Model Simulations , 2009 .

[57]  Louis Wehenkel,et al.  Whither probabilistic security management for real-time operation of power systems? , 2013, 2013 IREP Symposium Bulk Power System Dynamics and Control - IX Optimization, Security and Control of the Emerging Power Grid.

[58]  M.H.J. Bollen,et al.  On Operational Risk Assessment in Transmission Systems - Weather Impact and Illustrative Example , 2008, Proceedings of the 10th International Conference on Probablistic Methods Applied to Power Systems.

[59]  Árni Jón Elíasson Natural hazards and the Icelandic power transmission grid , 2005 .