This research is based on the altitude temperature, pressure and humidity, as defined by MIL-HDBK-310 standard and modifies this conditions to conform to the new standard MIL-STD-810F and test procedure given in AIAA-2466 from this fundamental guideline optimal design and sizing of test section, inlet, exhauster duct, temperature and humidity control was performed